Notifications
You must be signed in to change notification settings - Fork 5
/
pitch_control.m
132 lines (132 loc) · 3.55 KB
/
pitch_control.m
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
%% State Space representation
A=[-0.313 56.7 0; -0.0139 -0.426 0; 0 56.7 0];
B=[0.232; 0.0203; 0];
C=[0 0 1];
D=[0];
state_space=ss(A,B,C,D) %State Space representation of system
%% Open Loop Transfer Function and Analysis
[num,den]=ss2tf(A,B,C,D,1); %To convert state space model to transfer function
open_loop_tf=tf(num,den)
t=[0:0.01:15];
figure(1);
subplot(2,1,1);
impulse(open_loop_tf,t); %Computing open loop impulse response
xlabel('Time');
ylabel('Pitch angle(rads)');
title('Open Loop impulse response');
subplot(2,1,2);
step(open_loop_tf,t); %Computing open loop step response
xlabel('Time');
ylabel('Pitch angle(rads)');
title('Open Loop step response');
figure(2);
pzplot(open_loop_tf);
%% Closed Loop Response
pole(open_loop_tf)
sys_cl = feedback(open_loop_tf,1)
figure(3);
subplot(2,1,1);
impulse(sys_cl); %Computing closed loop Impulse response
xlabel('Time');
ylabel('Pitch angle(rads)');
title('Closed Loop Impulse response');
subplot(2,1,2);
step(sys_cl); %Computing closed loop Step response
xlabel('time');
ylabel('pitch angle (rad)');
title('Closed-loop Step Response');
poles = pole(sys_cl);
zeros = zero(sys_cl);
s = tf('s');
R = 1/s;
Y = zpk(sys_cl*R);
%[r,p,k] = residue([1.151 0.1774],[1 0.739 2.072 0.1774 0])
%[num,den] = residue(r(1:2),p(1:2),k);
%tf(num,den)
%% PID Controller Design
controlSystemDesigner(open_loop_tf)
%% Controllability & Observability
A = [-0.313 56.7 0; -0.0139 -0.426 0; 0 56.7 0];
B = [0.232; 0.0203; 0];
C = [0 0 1];
D = [0];
co = ctrb(A,B);
Controllability = rank(co)
%% LQR method
p = 590;
Q = p*C'*C
R = 1;
[K] = lqr(A,B,Q,R)
Nbar = rscale(A,B,C,D,K)
sys_cl_1 = ss(A-B*K, B*Nbar, C, D)
figure(4);
subplot(2,1,1);
step(sys_cl_1);
ylabel('pitch angle (rad)');
xlabel('Time(sec)');
title('Closed-Loop Step Response: LQR with Precompensation');
%% Digital Control System
sys_ss = ss(A,B,C,D);
Ts = 1/100;
sys_d = c2d(sys_ss,Ts,'zoh')
%% Controllability of Digital Sysstem
co = ctrb(sys_d);
Controllability = rank(co) % Controllability of digital system
%% LQR Method for Digital Control System
A = sys_d.a;
B = sys_d.b;
C = sys_d.c;
D = sys_d.d;
p = 50;
Nbar_d = 6.95;
Q = p*C'*C
R = 1;
[K] = dlqr(A,B,Q,R)
time = 0:0.01:10;
theta_des = 0.2*ones(size(time));
sys_cl_d = ss(A-B*K,B*Nbar_d,C,D,Ts);
[y,t] = lsim(sys_cl_d,theta_des);
figure(4);
subplot(2,1,2);
stairs(t,y)
xlabel('time (sec)');
ylabel('pitch angle (rad)');
title('Closed-Loop Step Response: DLQR with Precompensation');
%% R-scale function
function[Nbar]=rscale(a,b,c,d,k)
% Given the single-input linear system:
% .
% x = Ax + Bu
% y = Cx + Du
% and the feedback matrix K,
% the function rscale(sys,K) or rscale(A,B,C,D,K)
% finds the scale factor N which will
% eliminate the steady-state error to a step reference
% for a continuous-time, single-input system
% with full-state feedback using the schematic below:
%
% /---------\
% R + u | . |
% ---> N --->() ---->| X=Ax+Bu |--> y=Cx ---> y
% -| \---------/
% | |
% |<---- K <----|
%
error(nargchk(2,5,nargin));
% --- Determine which syntax is being used ---
nargin1 = nargin;
if (nargin1==2), % System form
[A,B,C,D] = ssdata(a);
K=b;
elseif (nargin1==5), % A,B,C,D matrices
A=a; B=b; C=c; D=d; K=k;
else error('Input must be of the form (sys,K) or (A,B,C,D,K)')
end;
% compute Nbar
s = size(A,1);
Z = [zeros([1,s]) 1];
N = inv([A,B;C,D])*Z';
Nx = N(1:s);
Nu = N(1+s);
Nbar=Nu + K*Nx;
end