##1 make a directory adjacent to ANONRAW for the MANUAL_FIX.
cd /Shared/nopoulos/structural/oz_MR/S104/S104-v1/ mkdir MANUAL_FIX cd MANUAL_FIX
##2 Copy the failed “EMSP* files from the failied BCD ron to the MANUAL_FIX directory”
cp /Shared/nopoulos/structural/oz_MR/BAWEXPERIMENT_20180329/20180329_OZ_base_CACHE/singleSession_S104_S104-v1/LandmarkInitialize/BCD/EMSP.nrrd S104_S104-v1_T1_EYES_FIXED.nrrd
cp /Shared/nopoulos/structural/oz_MR/BAWEXPERIMENT_20180329/20180329_OZ_base_CACHE/singleSession_S104_S104-v1/LandmarkInitialize/BCD/EMSP.fcsv EMSP.fcsv
##3 In slicer version 4.8.1 (October 2017 release) open the .nrrd and .fcsv files
##4 Creat a _noDenoise file to indicate that previous steps need to be skipped. touch S104_S104-v1_T1_EYES_FIXED.nrrd_noDenoise
NOTE: BCD fails after this correction method with following error: So BCD failed with following error: cat /Shared/nopoulos/structural/oz_MR/BAWEXPERIMENT_20180329/20180329_OZ_base_CACHE/singleSession_S104_S104-v1/LandmarkInitialize/BCD/BCD_FAILED.txt
itk::ExceptionObject (0x49c2970) Location: "unknown" File: /Shared/pinc/sharedopt/20170302/RHEL7/NEP-intel/BRAINSTools/BRAINSConstellationDetector/src/landmarksConstellationDetector.cxx Line: 488 Description: itk::ERROR: Zero norm for bounding area.