Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Added Alert Procedure to guidebook #1311

Merged
merged 2 commits into from
Jun 12, 2024
Merged
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
1 change: 1 addition & 0 deletions Resources/Locale/en-US/deltav/guidebook/guides.ftl
Original file line number Diff line number Diff line change
@@ -1 +1,2 @@
guide-entry-alert-levels = Alert Levels
guide-entry-justice = Justice
4 changes: 4 additions & 0 deletions Resources/Prototypes/DeltaV/Guidebook/command.yml
Original file line number Diff line number Diff line change
@@ -0,0 +1,4 @@
- type: guideEntry
id: AlertProcedure
name: guide-entry-alert-levels
text: "/ServerInfo/Guidebook/DeltaV/AlertProcedure.xml"
Original file line number Diff line number Diff line change
Expand Up @@ -356,6 +356,9 @@
parent: AlwaysPoweredWallLight
suffix: ""
components:
- type: GuideHelp # DeltaV guide
guides:
- AlertProcedure
- type: PointLight
enabled: false
radius: 5
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -591,6 +591,9 @@
- type: Damageable
damageContainer: Inorganic
damageModifierSet: StrongMetallic
- type: GuideHelp # DeltaV guide
guides:
- AlertProcedure

- type: entity
parent: ComputerComms
Expand Down
2 changes: 2 additions & 0 deletions Resources/Prototypes/Guidebook/shiftandcrew.yml
Original file line number Diff line number Diff line change
Expand Up @@ -20,6 +20,8 @@
id: Survival
name: guide-entry-survival
text: "/ServerInfo/Guidebook/Survival.xml"
children: # DeltaV
- AlertProcedure

- type: guideEntry
id: Janitorial
Expand Down
90 changes: 90 additions & 0 deletions Resources/ServerInfo/Guidebook/DeltaV/AlertProcedure.xml
Original file line number Diff line number Diff line change
@@ -0,0 +1,90 @@
<Document>
# Alert Procedure
Alert levels exist on the station to advise the crew at-large of the state of the station's overall security or well-being. Setting an alert level via the communications computer is an immediate action, so it is often done after sending a message to the crew.
<Box>
<GuideEntityEmbed Entity="ComputerComms" Caption="This sets the alert level."/>
<GuideEntityEmbed Entity="EmergencyLight" Caption="This displays the alert level."/>
</Box>
On Delta-V, there are some restrictions on when certain alert levels can be used. They should be somewhat intuitive, but they are elaborated on as follows:

## Code Green
[color=#7cfc00]Regular operating conditions, absent or manageable station threat(s) present.[/color]
- [color=#a4885c]Chain of Command (COC)[/color]: Commanding Officer (CO), Department Heads, Supervisory Roles
- [color=#a4885c]Armory Policy[/color]: Open carrying of long arms disallowed. Standard soft or hard ballistic armor recommended for all security personnel.
- [color=#a4885c]Discipline[/color]: Report to supervisor for general orders.
- [color=#a4885c]Secure Areas[/color]: Secure areas unlocked and accessible to all authorized personnel. High Security Areas and areas with an expectation of privacy, such as bedrooms, dorms, or medical treatment facilities, may be locked as needed.
- [color=#a4885c]Medical[/color]: Standard practice.
- [color=#a4885c]Engineering[/color]: Standard practice.
- [color=#a4885c]Rules of Engagement (ROE)[/color]: Engage with minimal force; prioritize de-escalation whenever possible.

## Code Blue
[color=#0000FF]Elevated alert status. There is an ongoing, known, or suspected security threat to the NanoTrasen vessel or its crew.[/color]
- [color=#a4885c]COC[/color]: CO, Head of Security, Department Heads, Supervisory Roles
- [color=#a4885c]Armory Policy[/color]: Open carrying weaponry permitted for all security personnel. Standard ballistic armor mandatory for security personnel, soft armor authorized for all other personnel.
- [color=#a4885c]Discipline[/color]: Report to supervisor for general orders. Random searches may be performed at the discretion of security personnel and without a warrant.
- [color=#a4885c]Secure Areas[/color]: Secure areas unlocked unless affected by known threats. Access to HSAs locked.
- [color=#a4885c]Medical[/color]: Binary suit sensors recommended at a minimum. EVA suits recommended for emergency responders, functioning internals and PPE heavily advised.
- [color=#a4885c]Engineering[/color]: EVA suits recommended for engineers. Make emergency internals easily accessible.
- [color=#a4885c]ROE[/color]: Engage with minimal force; non-lethal weapons may be used freely based on threat and compliance.

## Code Red
[color=#ff0000]Emergency alert status. There is a major security emergency affecting the station.[/color]
- [color=#a4885c]COC[/color]: CO, Head of Security, Security Personnel, Department Heads, Supervisory Roles
- [color=#a4885c]Armory Policy[/color]: Open carrying weaponry permitted for all security personnel. Standard ballistic armor mandatory, EVA suits heavily advised.
- [color=#a4885c]Discipline[/color]: Report to supervisor for general orders. Searches and departmental raids may be performed at the discretion of security personnel and without a warrant. Open carry disallowed for non-security personnel.
- [color=#a4885c]Secure Areas[/color]: All HSAs should remain locked and under guard. Secure areas unlocked unless affected by known threats.
- [color=#a4885c]Medical[/color]: Full suit sensors mandatory for observation and safety. EVA suits and functioning internals heavily advised for emergency responders.
- [color=#a4885c]Engineering[/color]: EVA suits heavily advised for engineers. Distribute emergency internals to crew.
- [color=#a4885c]ROE[/color]: Engage with necessary force; lethal force is permitted in self-defense, or to effect an arrest; non-lethal methods must be attempted first.

## Code Violet
[color=#7f00ff]Elevated alert status. There is a serious viral outbreak, ongoing major death event, or there is another significant medical emergency.[/color]
- [color=#a4885c]COC[/color]: CO, Chief Medical Officer, Medical Personnel, Department Heads, Supervisory Roles
- [color=#a4885c]Armory Policy[/color]: Open carrying of long arms disallowed. Standard soft or hard ballistic armor recommended for all security personnel. Basic PPE mandatory for all personnel, level 3 biohazard gear heavily advised.
- [color=#a4885c]Discipline[/color]: Report to supervisor for orders. Non-medical personnel should ensure they do not interfere with medical staff, may assist where applicable, obey all applicable orders from medical personnel. Security should seek to aid medical staff in enforcement of quarantine procedures or medical treatment as necessary.
- [color=#a4885c]Secure Areas[/color]: Secure areas unlocked and accessible to all authorized personnel. High Security Areas and areas with an expectation of privacy, such as bedrooms, dorms, or medical treatment facilities, may be locked as needed.
- [color=#a4885c]Medical[/color]: Report to supervisor for orders. Full suit sensors heavily advised. EVA suits recommended for emergency responders, functioning internals and PPE heavily advised.
- [color=#a4885c]Engineering[/color]: Standard practice.
- [color=#a4885c]ROE[/color]: Engage with minimal force; prioritize de-escalation whenever possible.

## Code Yellow
[color=#ffff00]Elevated alert status. There is a major issue with the atmospheric system, the station has suffered/is about to suffer significant damage, or there is another significant engineering emergency.[/color]
- [color=#a4885c]COC[/color]: CO, Chief Engineer, Engineering Personnel, Department Heads, Supervisory Roles
- [color=#a4885c]Armory Policy[/color]: Open carrying of long arms disallowed. Standard soft or hard ballistic armor recommended for all security personnel. EVA suits heavily advised.
- [color=#a4885c]Discipline[/color]: Report to supervisor for orders. Non-engineering personnel advised to evacuate affected areas and obey any relevant instructions from engineering personnel. Security should seek to aid engineering staff where possible.
- [color=#a4885c]Secure Areas[/color]: Secure areas unlocked and accessible to all authorized personnel. High Security Areas and areas with an expectation of privacy, such as bedrooms, dorms, or medical treatment facilities, may be locked as needed.
- [color=#a4885c]Medical[/color]: Full suit sensors heavily advised. EVA suits and functioning internals recommended for emergency responders.
- [color=#a4885c]Engineering[/color]: EVA suits heavily advised for engineers. Distribute emergency internals to crew. Propose evacuation if damage is irreparable or sufficiently hazardous.
- [color=#a4885c]ROE[/color]: Engage with minimal force; prioritize de-escalation whenever possible.

## Code White
[color=#f6ccf6]Elevated alert status. The station is suffering dangerously high levels of glimmer, there are several active psionic threats, or there is another significant epistemic emergency.[/color]
- [color=#a4885c]COC[/color]: CO, Mystagogue, Epistemics Personnel, Department Heads, Supervisory Roles
- [color=#a4885c]Armory Policy[/color]: Open carrying weaponry permitted for all security personnel. Standard ballistic armor mandatory for security personnel, soft armor authorized for all other personnel. Psionic insulation recommended.
- [color=#a4885c]Discipline[/color]: Report to supervisor for orders. Security and engineering should seek to aid epistemics staff in shutting off glimmer probers, and propose evacuation if glimmer spiral is unrecoverable.
- [color=#a4885c]Secure Areas[/color]: Secure areas unlocked and accessible to all authorized personnel, unless affected by a known threat. High Security Areas and areas with an expectation of privacy, such as bedrooms, dorms, or medical treatment facilities, may be locked as needed.
- [color=#a4885c]Medical[/color]: Full suit sensors heavily advised. Prepare for increased incidents of burn and brain damage.
- [color=#a4885c]Engineering[/color]: EVA suits heavily advised for engineers. Distribute emergency internals to crew.
- [color=#a4885c]ROE[/color]: Engage with minimal force; RoE on minbreaking is lifted.

## Code Gamma
[color=#db7093]Emergency alert status. Central Command has called the Gamma Alert; the Station is on its last legs, almost everyone is dead, or there is another existential crisis affecting the station.[/color]
- [color=#a4885c]COC[/color]: CO, Head of Security, Security Personnel, Department Heads, Supervisory Roles
- [color=#a4885c]Armory Policy[/color]: Open carrying weaponry permitted for all security personnel. Standard ballistic armor mandatory, EVA suits heavily advised.
- [color=#a4885c]Discipline[/color]: Report to supervisor for general orders. Martial law is in effect. Open carry disallowed for non-security personnel. Searches and departmental raids may be performed at the discretion of security personnel and without a warrant. Arrests of officers permitted at discretion of security personnel. Threats that have been incapacitated by lethal force may be kept in Preservative Stasis until Code Gamma has been rescinded. Security is fully authorized to take whatever actions deemed necessary to neutralize or repel station threats. Propose evacuation or scuttling if station cannot be retaken.
- [color=#a4885c]Secure Areas[/color]: All HSAs should remain locked and under guard. Secure areas unlocked unless affected by known threats.
- [color=#a4885c]Medical[/color]: Full suit sensors mandatory for observation and safety. EVA suits and functioning internals heavily advised for emergency responders.
- [color=#a4885c]Engineering[/color]: EVA suits heavily advised for engineers. Distribute emergency internals to crew.
- [color=#a4885c]ROE[/color]: Engage with necessary force; lethal force is permitted in self-defense, or to effect an arrest.

## Code Delta
[color=#8b0000]Emergency alert status. The nuclear destruction mechanism has been engaged and station destruction is imminent. All crew aboard the station must attempt to reverse the self-destruct mechanism, if engaged in error. Should reversal prove impossible, evacuate as applicable.[/color]
- [color=#a4885c]COC[/color]: CO, Head of Security, Security Personnel, Department Heads, Supervisory Roles
- [color=#a4885c]Armory Policy[/color]: Open carrying weaponry permitted for all security personnel. Standard ballistic armor mandatory, EVA suits heavily advised.
- [color=#a4885c]Discipline[/color]: All personnel must expend all efforts to prevent station destruction. Martial law is in effect. Searches and departmental raids may be performed at the discretion of security personnel and without a warrant. Arrests of officers permitted at discretion of security personnel. Threats that have been incapacitated by lethal force may be kept in Preservative Stasis until Code Delta has been rescinded. Security is fully authorized to take whatever actions deemed necessary to neutralize or repel station threats.
- [color=#a4885c]Secure Areas[/color]: All secure areas and HSAs should remain unlocked.
- [color=#a4885c]Medical[/color]: Full suit sensors heavily advised. EVA suits and functioning internals heavily advised for emergency responders.
- [color=#a4885c]Engineering[/color]: EVA suits heavily advised for engineers. Distribute emergency internals to crew.
- [color=#a4885c]ROE[/color]: Engage with necessary force; lethal force is permitted in self-defense, or to effect an arrest.

</Document>
Loading