Skip to content

Tool used in the develpment of FOSS for applications by Carthage Space Sciences, WSGC, & NASA. Designed to interface with gator device 🐊

Notifications You must be signed in to change notification settings

Fiber-Optic-Sensing-System/mpg-foss

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

GitHub release (latest by date including pre-releases)

About

This tool

mpg-foss-α is a Software tool used in the develpment of fiber optic sensing systems (foss) for applications by Carthage Space Sciences, WSGC, & NASA. Designed to interface with interrogator (gator) devices. This software is designed to interface with intrinsic fiber optic sensing technology, whereby the fiber optic cable itself is the sensor.

Further into the development lifecycle, this program may be used in conjunction with a specific foss application called modal propellant gauging (mpg).

Fiber optic sensing systems

Fiber optic sensing systems (foss) use the physical properties of light as it travels along a fiber to detect changes in temperature, strain, and other parameters. There are, generally speaking, three generations of technologies: point fiber bragg grating (FBG) based sensors, scattering and spatially continuous FBG based. Scattering techniques take fully distributed measurements while FBG techniques can have a handful of sensing points or be fully distributed depending on how the system interprets the signal from the sensing element. FBGs act as miniscule mirrors and are manufactured into the core of the fiber. As light travels down the fiber, each grating reflects a portion of the signal back to the system. The system recognizes changes in the returning signal and interprets this information to provide accurate strain and temperature measurements.

Below is a diagram pointing out the structure of an optical fiber containing a Fiber Bragg Grating structure - the figure displays a refractive index profile and spectral response:



Benefits of the technology

Strain gauges and thermocouples have long been the standard for measuring strain and temperature during testing. While these technologies have been good enough for decades, they are not always able to effectively test and monitor the innovations of today. The limitations of legacy technology are not about accuracy, rather it is primarily about the level of insight provided by the data. Strain gauges and thermocouples only provide points of information, while some types of fiber optic sensors can provide spatially continuous data along the entire length of the fiber. As a result, engineers can measure strain fields and temperature distributions on a structure in order to better understand how the component behaves under different conditions. While point sensors only allow engineers to monitor critical points, distributed (spatially continuous data) sensors can measure what happens at critical points and everywhere in between. This level of insight is invaluable when it comes to designing with new composite materials. Additionally, fiber optic sensors can be embedded in materials in order to provide greater insight into the internal behavior of composite components and structures.

General usage

  • mpg-foss-α requires at least Python 3.10.0.

  • Start by downloading or git cloneing the source code.

    • Extract the repo folder if you downloaded the main branch directly.
  • Use the foss.py script in the root directory to execute commands.

    • deps gets required modules.
    • data starts gator hardware data retrieval.
    • clean removes parsed data .csv files.
    • sim starts usb gator data output simulation.
    • help to list commands.
  • Invoke the foss.py script like you would any other Python script file.

    • e.g. python foss.py wisdom
  • mpg-foss-α does not use Pipenv at the moment. Instead, there is a built in bootstrapper/update tool that should be invoked using python foss.py deps.


Examples





Notes

Unit Conversion

The central wavelengths (CoG bit numbers) that are generated by Gator devices are absolute, calibrated central wavelengths in the operating range of the gator. To make full use of the available 18 bit register, the following conversion can be used to determine the actual central wavelength λCW in nm.

$$ λ_{CW} = \frac{1514 + CoG_{bit}}{2^{18} * 72} $$

In order to determine the strain ε or temperature change ΔT induced on an FBG sensor, one first has to know the default central wavelength value1 (unstrained / room Temperature) for the particular sensor, defined as λ0... The relation between wavelength and strain and temperature is then as followed:

$$\frac{\Delta\lambda}{\lambda_{0}}=\left( 1-\rho_e \right)\cdot \epsilon+\left( \alpha_\Lambda - \alpha_n \right)\bullet \Delta T$$

Here pe is the strain-optic coefficient (0.22 for a glass fiber), ε the strain, αΛ the thermal expansion coefficient, αn thermo-optic coefficient and ΔT the induced temperature change. For a bare glass fiber the temperature dependence ∆λ/ΔT is typically in the order of 10 pm/°C at 1550 nm wavelength.

Footnotes