You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
and I get correct output for some servers and error for other. I don't see any reason for that kind of behavior.
Expected Behavior
componentName componentLocation componentVersion
----------------------------------------------
qlnativefc: QLogic Fibre Channel HBA Driver 4.1.22.0-1OEM.700.1.0.15843807
Intelligent Platform Abstraction Data System Board 15.1.0 Build 33
lpfc: Broadcom Emulex Connectivity Division lpfc driver for FC adapters 12.8.329.1-1OEM.700.1.0.15843807
Intel NVME Driver with VMD Technology 2.0.0.1055-5vmw.701.0.0.16850804
System ROM System Board I42 v2.72 (09/29/2022)
Network ENS driver for VMware vmxnet3 Virtual Ethernet Controller 2.0.0.22-1vmw.701.0.0.16850804
HPE 2SFF NVMe/SAS/uFF Backplane Box=11.20
VMware Native AHCI Driver 2.0.5-2vmw.701.0.0.16850804
ATA Driver 0.1-1vmw.701.0.25.17325551
rste: SCU SAS/SATA for VMware ESX 2.0.2.0088-7vmw.701.0.0.16850804
QLogic NetXtreme II 10 Gigabit Network/iSCSI/FCoE E3 drivers for VMware ESXi 3.0.140.2-1OEM.700.1.0.15843807
Mellanox NATIVE_NMST Drivers 4.14.3.3-1OEM.700.1.0.15525992
INTEL VMD LSU Management Plugin 1.0.0-2vmw.701.0.0.16850804
ESXi Install/Upgrade Component 7.0.1-0.30.17551050
Mellanox Native OFED ConnectX-3 Drivers 3.19.70.1-1OEM.670.0.0.8169922
igbn: Network driver for Intel(R) 1 Gigabit Server NIC 1.5.2.0-1OEM.700.1.0.15843807
NVME PCIe LSU Management Plugin 1.0.0-1vmw.701.0.0.16850804
PVSCSI Driver 0.1-2vmw.701.0.0.16850804
Synergy 5330C 32Gb FC HBA Mezzanine Slot 212.8.352.12
Command line tool for interacting with the iLO Rest API. 700.3.1.0.43-15843807
Broadcom NetXtreme-E VMKAPI network and RoCE driver 218.0.243.0-1OEM.700.1.0.15843807
cru: cru driver 700.10.16-1OEM.700.0.0.14828939
smartpqi: SmartPqi Native driver 70.4054.2.118-1OEM.700.1.0.15843807
amshelprComponent: Agentless Management Service for Gen9 701.11.7.0.14-1
sut: Integrated Smart Update Tool 700.2.8.0.20-0
HPE Utility Component for ESXi 7.010.5.0-6310.5.0-63
Networking Driver for Intel PRO/1000 Family Adapters 0.8.4-11vmw.701.0.0.16850804
Redundant System ROM System Board I42 v2.54 (09/03/2021)
Network driver for VMware vmxnet3 Virtual Ethernet Controller 2.0.0.30-1vmw.701.0.0.16850804
Marvell Technology Network/iSCSI/FCoE/RDMA E4 drivers for VMware ESXi 5.0.254.0-1OEM.700.1.0.15843807
SMARTPQI LSU Management Plugin 1.0.0-4vmw.701.0.0.16850804
smx:WBEM Providers for ESXi 7.0700.03.16.00.12-14828939
NVMe Drive NVMe Drive Port 1A Box 1 Bay 2 HPK3
Mellanox Native OFED ConnectX-4-5 Drivers 4.19.70.1-1OEM.700.1.0.15525992
Virtual NIC Enablement Bundle for ESXi 700.1.00.12-1
net driver for VMware ESX 12.0.1250.0-5vmw.701.0.0.16850804
NVMe Backplane Firmware System Board 1.20
Intelligent Provisioning System Board 3.40.192
NVMe Drive NVMe Drive Port 1A Box 1 Bay 1 HPK3
Innovation Engine (IE) Firmware System Board 0.2.2.0
Server Platform Services (SPS) Firmware System Board 4.1.4.423
OEM HP LSU Management Plugin 1.0.0-1vmw.701.0.0.16850804
net driver for VMware ESX 11.4.62.0-1vmw.701.0.0.16850804
Broadcom NetXtreme I ESX VMKAPI ethernet driver 4.1.5.0-0vmw.701.0.0.16850804
brcmnvmefc: Broadcom NVMeF FC Driver 12.8.329.0-1OEM.700.1.0.15843807
Network driver for QLogic NetXtreme II PCI/PCIe Gigabit Ethernet Adapters 1.1.0.11-1vmw.701.0.0.16850804
Network driver for Intel(R) X722 RDMA Adapters 1.1.2.6-1vmw.701.0.0.16850804
Broadcom Native MegaRAID SAS 7.712.51.00-1vmw.701.0.0.16850804
Emulex FCoE Driver 12.0.1500.0-1vmw.701.0.0.16850804
icen: Network driver for Intel(R) E810 Adapters 1.4.2.0-1OEM.700.1.0.15843807
i40en: Network driver for Intel(R) X710/XL710/XXV710/X722 Adapters 1.10.9.0-1OEM.700.1.0.15525992
HPE Smart Array S100i SR Gen10 Embedded Device 2.04-0
Non-Volatile memory controller driver 1.2.3.9-2vmw.701.0.0.16850804
Synergy 6820C 25/50Gb CNA Mezzanine Slot 38.55.22
Power Management Controller FW Bootloader System Board 1.1
System Programmable Logic Device System Board 0x0D
IMA plugin for elxiscsi driver 12.0.1200.0-3vmw.701.0.0.16850804
Server Platform Services (SPS) Descriptor System Board 1.20
Smart Storage Administrator CLI for ESXi 5.10.45.1-7.0.0
HPSA native driver 70.0051.0.100-2vmw.701.0.25.17325551
ESXi Component - core ESXi VIBs 7.0.1-0.30.17551050
VMware NVME over RDMA Driver 1.0.1.2-1vmw.701.0.20.17325020
ilo: ilo driver 700.10.7.0.6-1OEM.700.1.0.15843807
HPSA LSU Management Plugin 1.0.0-3vmw.701.0.0.16850804
iLO 5 System Board 2.70 May 162022
Power Management Controller Firmware System Board 1.0.7
LSI NATIVE DRIVERS LSU Management Plugin 1.0.0-4vmw.701.0.0.16850804
iscsi driver for VMware ESX 12.0.1200.0-2vmw.701.0.0.16850804
Fiber Channel and Storage Enablement Bundle for ESXi 700.3.7.0.5-1
esxcli plugin for VMware nvme driver 1.2.0.38-1vmw.701.0.0.16850804
Native Software FCoE Driver for VMware ESX 1.0.0.2-1vmw.701.0.20.17325020
amsdComponent: Agentless Management Service for Gen10 and Gen10Plus 701.11.7.1.3-1
VMware Native iSER Driver 1.1.0.1-1vmw.701.0.0.16850804
HPE Upgrade Component for ESXi 7.0.01.1.4-1OEM.700.1.0.15843807
ixgben: Network driver for Intel(R) 10 Gigabit Adapters 1.8.9.0-1OEM.700.1.0.15525992
USB Driver 0.1-1vmw.701.0.25.17325551
Actual Behavior
Line |125| (Send-OVRequest-Uri ($server.serverFirmwareInventoryUri)).compo …
| ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
| An unexpected and unhandled runtime exception occurred. Please contact your authorized support representative
| and provide them with a support dump.
Steps to reproduce
Maybe it isn't relevant but all servers with error had warning: "BIOS settings do not match the expected values.". Even after BIOS reconfiguration and server restart, error after above command stay the same.
Module version 8.00, PowerShell 7.3.5, OneView version 8.10
Error is reproducible. Am I missing something?
The text was updated successfully, but these errors were encountered:
Hi Chris,
Same error and output is with Show-OVFirmwareReport.
Regards,
Miloš Kasalica
Customer Support Engineer
Hewlett Packard Enterprise
operated by Selectium
***@***.******@***.***>
+381 63 290 014<tel:+381%2063%20290%20014> Mobile
[cid:storage_emulated_0_Android_data_com_samsung_android_email_provider_files__EmailTempImage_1_TempSignature_signature_image004_jpg_1663253366251]
-------- Original message --------
From: Chris Lynch ***@***.***>
Date: 22/09/2023 00:49 (GMT+01:00)
To: HewlettPackard/POSH-HPEOneView ***@***.***>
Cc: Milos Kasalica ***@***.***>, Author ***@***.***>
Subject: Re: [HewlettPackard/POSH-HPEOneView] Error while collecting firmware report (Issue #645)
Is there a reason why you are not using Show-OVFirmwareReport<https://hpe-docs.gitbook.io/posh-hpeoneview/cmdlets/v8.00/servers/show-ovfirmwarereport>?
—
Reply to this email directly, view it on GitHub<#645 (comment)>, or unsubscribe<https://github.com/notifications/unsubscribe-auth/BBMZVTHK5XJPFWATEVGR4VLX3S777ANCNFSM6AAAAAA2RSJHUY>.
You are receiving this because you authored the thread.Message ID: ***@***.***>
This email is from an external domain! Caution is required when opening any attachments or external links
I'm trying to collect firmware for all servers in Synergy Frame with command:
or with command:
Show-OVFirmwareReport $server
and I get correct output for some servers and error for other. I don't see any reason for that kind of behavior.
Expected Behavior
Actual Behavior
Steps to reproduce
Maybe it isn't relevant but all servers with error had warning: "BIOS settings do not match the expected values.". Even after BIOS reconfiguration and server restart, error after above command stay the same.
Module version 8.00, PowerShell 7.3.5, OneView version 8.10
Error is reproducible. Am I missing something?
The text was updated successfully, but these errors were encountered: