Notifications
You must be signed in to change notification settings - Fork 4
/
Copy pathstep814_815.m
43 lines (38 loc) · 1.57 KB
/
step814_815.m
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
% Step 8.1.4: Obtain the field strength exceeded at 50% locations
% for a receiving/mobile antenna at the height of representative
% clutter, R, for the required values of distance, d, and
% transmitting/base antenna height, h1.
% Step 8.1.5: If the required distance does not coincide with the
% lower nominal distance, repeat Step 8.1.4 for the higher nominal
% distance and interpolate the two field strengths for distance
% using the method given in Annex 5, § 5.
% function E = step814_815(tabulatedValues,h1,dinf,dsup)
% if only step 8.1.4 is needed pass the same value for dinf and dsup.
% tabulatedValues a matrix of value from a figure 1-24 of excel sheet of
% values for recommendation. Expected range from table 'B6:K84' may still
% work with different range value. results unexpected.
% h1 must equal one of the nominal value 10,20,37.5,75,150,300,600,1200 if
% not return is unknown.
% dinf and dsup must correspond to values in Table 1 of ITU-r p.1546 on
% page 38 otherwise NaN will be returned
%
% Returns a single field strength value for the given parameters with or
% wit
function E = step814_815(tabulatedValues,h1,dinf,dsup,d)
eLookUp = tabulatedValues(1,:)== h1;
eLookUp = [tabulatedValues(:,1) tabulatedValues(:,eLookUp)];
Einf = eLookUp(:,1) == dinf;
Einf = eLookUp(Einf,2);
Esup = eLookUp(:,1) == dsup;
Esup = eLookUp(Esup,2);
if dsup ~= dinf
Esup = eLookUp(:,1)==dsup;
Esup = eLookUp(Esup,2);
E = Einf+(Esup-Einf)*log10(d/dinf)/log10(dsup/dinf); %equ'n (13)
return
else
E = Esup;
return
end
E = NaN;
end