Skip to content
/ ERRM Public

Code for the Extended Reference Region Model for DCE-MRI (NBM 3924)

License

Notifications You must be signed in to change notification settings

MPUmri/ERRM

Repository files navigation

Extended Reference Region Model

Introduction

This repository contains code for the Extended Reference Region Model (ERRM) and the constrained ERRM (CERRM).

These models are described in: Ahmed, Z., & Levesque, I. R. (2018). An extended reference region model for DCE-MRI that accounts for plasma volume. NMR in Biomedicine

The fitting functions for the two models is in ./mfiles/ERRM.m and ./mfiles/CERRM.m respectively.

Code

This section contains the code used in the study and is organized by the order of figures. The code, results, and interactive figure (if available) for each figure is listed.

Figure 1, 2, 3

  • Code: e03_1_makeSimMap.m, e03_2_analyzeSimMap.m, e03_3_collectSimMap.m
  • Results: ./dataResults/e03a... and ./dataResults/e03b...
  • Interactive figures: Fig1 Fig2 Fig3

Figure 4, 5 & Table 1

  • Code: e04_1_doBrainSingle.m
  • Note: This script produces raw figures which were combined with external software

Figures 6, 7

  • Code: e04_2_doBrainDownsample.m
  • Results: ./e04-downsampleGbmResults.csv

Supplementary Figure S2

  • Code: e01_2_quickSimSingleCurve.m

Supplementary Figure S3

  • Code: e03_3b_getKepRR_hist.m

Supplementary Figure S4

  • Code: e04_2_doBrainDownsample.m

Note on acronyms

The manuscript discusses the following models:

  • Tofts Model (TM)
  • Extended Tofts Model (ETM)
  • Reference Region Model (RRM)
  • Extended Reference Region Model (ERRM)
  • Constrained Extended Reference Region Model (CERRM)

The code and the interactive figures include three additional models/methods:

  • Constrained Reference Region Model (CRRM) - Ref
  • Reference Tissue Method (RTM) - briefly described in manuscript
  • Extended Reference Tissue Method (ERTM)
    • Both the RTM and ERTM estimate the arterial input function from a reference tissue curve. The difference between them is that the RTM uses the input function to fit the TM to the tissue of interest, whereas the ERTM fits the ETM.
    • The RTM and ERTM have previously been explored in Ref

Even though these latter approaches did not play a major role in the manuscript, they have been included in the code and interactive figures on the off chance that someone finds them useful.

About

Code for the Extended Reference Region Model for DCE-MRI (NBM 3924)

Topics

Resources

License

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published