forked from evcc-io/evcc
-
Notifications
You must be signed in to change notification settings - Fork 0
/
evcc.dist.yaml
245 lines (224 loc) · 8.4 KB
/
evcc.dist.yaml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
network:
# schema is the HTTP schema
# setting to `https` does not enable https, it only changes the way URLs are generated
schema: http
# host is the hostname or IP address
# if the host name contains a `.local` suffix, the name will be announced on MDNS
# docker: MDNS announcements don't work. host must be set to the docker host's name.
host: evcc.local
# port is the listening port for UI and api
# evcc will listen on all available interfaces
port: 7070
interval: 10s # control cycle interval
# database configuration for persisting charge sessions and settings
# database:
# type: sqlite
# dsn: <path-to-db-file>
# sponsor token enables optional features (request at https://sponsor.evcc.io)
# sponsortoken:
# telemetry enables aggregated statistics
#
# Telemetry allows collecting usage data (grid and green energy, charge power).
# Data is aggregated, no individual charging sessions are tracked. The collected,
# anonymous data can be retrieved using https://api.evcc.io.
#
# See https://github.com/evcc-io/evcc/pull/4343 or details.
#
# For time being, this is only available to sponsors, hence data is associated with
# the sponsor token's identity.
#
# telemetry: true
# log settings
log: info
levels:
site: debug
lp-1: debug
lp-2: debug
cache: error
db: error
# modbus proxy for allowing external programs to reuse the evcc modbus connection
# each entry will start a proxy instance at the given port speaking Modbus TCP and
# relaying to the given modbus downstream device (either TCP or RTU, RS485 or TCP)
modbusproxy:
# - port: 5200
# uri: solar-edge:502
# # rtu: true
# # readonly: true
# meter definitions
# name can be freely chosen and is used as reference when assigning meters to site and loadpoints
# for documentation see https://docs.evcc.io/docs/devices/meters
meters:
- name: grid
type: modbus
model: sdm # SDM630
uri: rs485.fritz.box:23
rtu: true # rs485 device connected using ethernet adapter
id: 2
power: Power # default value, optionally override
energy: Sum # default value, optionally override
- name: pv
type: ...
- name: battery
type: ...
- name: charge
type: ...
- name: aux
type: ...
# charger definitions
# name can be freely chosen and is used as reference when assigning charger to vehicle
# for documentation see https://docs.evcc.io/docs/devices/chargers
chargers:
- name: wallbe
type: wallbe # Wallbe charger
uri: 192.168.0.8:502 # ModBus address
- name: keba
type: ...
# vehicle definitions
# name can be freely chosen and is used as reference when assigning vehicle to loadpoint
# for documentation see https://docs.evcc.io/docs/devices/vehicles
vehicles:
- name: car1
type: renault
title: Zoe
capacity: 60 # kWh
user: myuser # user
password: mypassword # password
vin: WREN...
onIdentify: # set defaults when vehicle is identified
mode: pv # enable PV-charging when vehicle is identified
minSoc: 20 # immediately charge to 0% regardless of mode unless "off" (disabled)
targetSoc: 90 # limit charge to 90%
# site describes the EVU connection, PV and home battery
site:
title: Home # display name for UI
meters:
grid: grid # grid meter
pv:
- pv # list of pv inverters/ meters
battery:
- battery # list of battery meters
aux: aux # auxiliary meters for adjusting grid operating point
prioritySoc: # give home battery priority up to this soc (empty to disable)
bufferSoc: # ignore home battery discharge above soc (empty to disable)
# loadpoint describes the charger, charge meter and connected vehicle
loadpoints:
- title: Garage # display name for UI
charger: wallbe # charger
meter: charge # charge meter
mode: "off" # set default charge mode, use "off" to disable by default if charger is publicly available
# vehicle: car1 # set default vehicle (disables vehicle detection)
resetOnDisconnect: true # set defaults when vehicle disconnects
phases: 3 # electrical connection (normal charger: default 3 for 3 phase, 1p3p charger: 0 for "auto" or 1/3 for fixed phases)
minCurrent: 6 # minimum charge current (default 6A)
maxCurrent: 16 # maximum charge current (default 16A)
# remaining settings are experts-only and best left at default values
priority: 0 # relative priority for concurrent charging in PV mode with multiple loadpoints (higher values have higher priority)
soc:
# polling defines usage of the vehicle APIs
# Modifying the default settings it NOT recommended. It MAY deplete your vehicle's battery
# or lead to vehicle manufacturer banning you from API use. USE AT YOUR OWN RISK.
poll:
# poll mode defines under which condition the vehicle API is called:
# charging: update vehicle ONLY when charging (this is the recommended default)
# connected: update vehicle when connected (not only charging), interval defines how often
# always: always update vehicle regardless of connection state, interval defines how often (only supported for single vehicle)
mode: charging
# poll interval defines how often the vehicle API may be polled if NOT charging
interval: 60m
estimate: true # set false to disable interpolating between api updates (not recommended)
enable: # pv mode enable behavior
delay: 1m # threshold must be exceeded for this long
threshold: 0 # grid power threshold (in Watts, negative=export). If zero, export must exceed minimum charge power to enable
disable: # pv mode disable behavior
delay: 3m # threshold must be exceeded for this long
threshold: 0 # maximum import power (W)
guardDuration: 5m # switch charger contactor not more often than this (default 5m)
# tariffs are the fixed or variable tariffs
tariffs:
currency: EUR # three letter ISO-4217 currency code (default EUR)
grid:
# either static grid price (or price zones)
type: fixed
price: 0.294 # EUR/kWh
zones:
- days: Mo-Fr
hours: 2-5
price: 0.2 # EUR/kWh
- days: Sa,So
price: 0.15 # EUR/kWh
# # or variable via tibber
# type: tibber
# token: "476c477d8a039529478ebd690d35ddd80e3308ffc49b59c65b142321aee963a4" # access token
# homeid: "cc83e83e-8cbf-4595-9bf7-c3cf192f7d9c" # optional if multiple homes associated to account
# # or variable via awattar
# type: awattar
# region: de # optional, choose at for Austria
feedin:
# rate for feeding excess (pv) energy to the grid
type: fixed
price: 0.08 # EUR/kWh
planner:
# planner tariff can be used for target charging if not grid tariff is specified
# GrünStromIndex (Germany only) or ElectricityMaps provide CO2 intensity forecast
# type: grünstromindex
# zip: <zip>
# type: electricitymaps
# uri: <uri>
# token: <token>
# zone: DE
# mqtt message broker
mqtt:
# broker: localhost:1883
# topic: evcc # root topic for publishing, set empty to disable
# user:
# password:
# influx database
influx:
# url: http://localhost:8086
# database: evcc
# user:
# password:
# eebus credentials
eebus:
# uri: # :4712
# interfaces: # limit eebus to specific network interfaces
# - en0
# certificate: # local signed certificate, required, can be generated via `evcc eebus-cert`
# public: # public key
# private: # private key
# push messages
messaging:
events:
start: # charge start event
title: Charge started
msg: Started charging in "${mode}" mode
stop: # charge stop event
title: Charge finished
msg: Finished charging ${chargedEnergy:%.1fk}kWh in ${chargeDuration}.
connect: # vehicle connect event
title: Car connected
msg: "Car connected at ${pvPower:%.1fk}kW PV"
disconnect: # vehicle connected event
title: Car disconnected
msg: Car disconnected after ${connectedDuration}
soc: # vehicle soc update event
title: Soc updated
msg: Battery charged to ${vehicleSoc:%.0f}%
guest: # vehicle could not be identified
title: Unknown vehicle
msg: Unknown vehicle, guest connected?
services:
# - type: pushover
# app: # app id
# recipients:
# - # list of recipient ids
# - type: telegram
# token: # bot id
# chats:
# - # list of chat ids
# - type: email
# uri: smtp://<user>:<password>@<host>:<port>/?fromAddress=<from>&toAddresses=<to>
# - type: ntfy
# uri: https://<host>/<topics>
# priority: <priority>
# tags: <tags>