FDL master must check who sent the token #9

Closed
Rahix opened this issue Mar 31, 2024 · 0 comments · Fixed by #18
Closed

FDL master must check who sent the token #9

Rahix opened this issue Mar 31, 2024 · 0 comments · Fixed by #18
Labels
correctness Behavioral Correctness of the Stack fdl Fieldbus Data Link

Comments

@Rahix
Copy link
Owner

Rahix commented Mar 31, 2024

The FDL master should not accept a token from anyone - only the actual previous active station in the token ring. When someone else tries to pass the token, it should only be accepted on the second attempt.

@Rahix Rahix added fdl Fieldbus Data Link correctness Behavioral Correctness of the Stack labels Mar 31, 2024
@Rahix Rahix added this to the Full Multi-Master Support milestone Mar 31, 2024
@Rahix Rahix closed this as completed in #18 Nov 1, 2024