Created on Mar 1 16:47:54 2023
@author: schneiderFTM
"""
#Calculation of new electric states and charging intelligence
# Load modules
import numpy as np
def electric_model(cell, T_Cell, SOC, p_value, z_eol_ri, z_eol_c, dt):
# Calculate new electric state according to power value, previous states and cell properties
# Determine internal resistance
R_i_ch = cell.R_i_ch_func(T_Cell, SOC) * (1+z_eol_ri)
R_i_dch = cell.R_i_dch_func(T_Cell, SOC) * (1+z_eol_ri)
# Determine cell volatage
Uocv = cell.ocv_func(SOC)
# Check if charging / discharging
if p_value > 0:
R_i = R_i_ch
else:
R_i = R_i_dch
# Value Calculation
Ibat = np.real((-Uocv + np.sqrt((Uocv ** 2) + (4 * R_i * p_value))) / (2 * R_i))
C_rate = Ibat / (cell.Qnom * z_eol_c)
SOC_new = SOC + (C_rate * dt / 3600)
P_Loss = (Ibat ** 2) * R_i
Q_throughput = Ibat * (dt/3600) # Ah
return SOC_new, C_rate, P_Loss, Q_throughput
def electric_control(cell, p_value, SOC, T_Cell, Crate,z_eol_ri, z_eol_c,target_soc, dt):
# Implementation of the CCCV charging protocol and overcharge prevention
# CCCV - Charging
if p_value > 0: # Check if vehicle is getting charged / Is current reduction needed ?
# Calculation of actual voltage, which has to be lower than maximal cell voltage
R_i_ch = cell.R_i_ch_func(T_Cell, SOC) * (1+z_eol_ri)
Uocv = cell.ocv_func(SOC)
Ibat = np.real((-Uocv + np.sqrt((Uocv ** 2) + (4 * R_i_ch * p_value))) / (2 * R_i_ch))
U_act = Uocv + Ibat * R_i_ch # Actual Voltage
# Degradation of current in order to achieve a lower voltage than maximal cell voltage // Constant Voltage
if U_act >= cell.Umax:
for i in range(1000):
if Uocv + Ibat*(1-0.001*i) * R_i_ch < cell.Umax:
p_value = Ibat*(1-0.001*i) * U_act
break
# Prevent Overcharge and Implementation of Charging Strategy
if p_value > 0:
# Check if in the next step the SOC is higher as the maximal cell SOC
if (SOC + ((Ibat/cell.Qnom * z_eol_c) * dt / 3600)) > cell.SOC_max:
p_value = 0 # Stop Charging due to Overcharge
if (SOC + ((Ibat/cell.Qnom * z_eol_c) * dt / 3600)) > target_soc: # if needed Energy is recharged at public charger -> stop charging
p_value = 0 # Stop Charging due no more energy is needed to complete mission
# Check if Battery Capacity is not Feasible
check_SOC = 0 # Battery Capacity is feasible // default
if p_value < 0:
if (SOC + (Crate * dt / 3600)) < cell.SOC_min:
check_SOC = 1 # Battery Capacity is not feasible
else:
pass
return p_value, check_SOC