From b1053d56b04d1343d2ff0c8f6796b500f1efb797 Mon Sep 17 00:00:00 2001 From: aletgn Date: Tue, 23 Apr 2024 16:55:16 +0200 Subject: [PATCH] fix typo --- docs/_pages/bgnd_fracture.rst | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/docs/_pages/bgnd_fracture.rst b/docs/_pages/bgnd_fracture.rst index 48b1464..56db212 100644 --- a/docs/_pages/bgnd_fracture.rst +++ b/docs/_pages/bgnd_fracture.rst @@ -28,7 +28,7 @@ where :math:`\sqrt{\text{area}}` is the projected area of the defect onto the pl .. math:: \Delta K = Y\, \Delta\sigma \sqrt{\pi\, \sqrt{\text{area}}} -where, in this case, :math:`Y` determined upon the distance between the defect's centroid and the free surface of the fatigue specimen :cite:`salvati_defect-based_2022`. +where, in this case, :math:`Y` is determined upon the distance between the defect's centroid and the free surface of the fatigue specimen :cite:`salvati_defect-based_2022`. Given the above, the EH curve is analytically defined as :cite:`zerbst_damage_2021`: