debug = true;
verboseDebug = false;
tempSetPoint = 23;
tempHysteresis = 0.1; // +/- (both ways)
thermostatEnabled = true;
// track state of the output
switchStatus = false;
Shelly.addStatusHandler(function(e) {
if (verboseDebug) print("Event: ", e);
if (e.component === "switch:0") {
if (e.delta.output === true) {
if (debug) print("Switch 0 is on, triggered source:", e.delta.source);
switchStatus = true;
if (e.delta.source === "SHC") {thermostatEnabled = true;} // command from the cloud means global on/off
}
else if (e.delta.output === false) {
if (debug) print("Switch 0 is off, triggered source:", e.delta.source);
switchStatus = false;
if (e.delta.source === "SHC") {thermostatEnabled = false;} // command from the cloud means global on/off
}
if (e.delta.output != null) // switch was toggled
if (debug) print("Main Thermostat Enable:", thermostatEnabled);
} // switch 0
});
function processTemperatures(data) {
if (verboseDebug) print("-> Temperature call finished: ", data);
// { "id": 100, "tC": 0, "tF": 32 }
// { "id": 100, "tC": null, "tF": null, "errors": ["read"] }
if (data.tC == "null") { // error handling
thermostatEnabled = false;
Shelly.call("Switch.Set", {"id": 0, "on": false});
if (debug) print ("ERROR reading temperature!");
}
else { // no error
let currentTemp = data.tC;
if (debug) print ("T = ", currentTemp );
if ((currentTemp <= (tempSetPoint - tempHysteresis)) && (!switchStatus)) {
if (debug) print ("Output set ON");
Shelly.call("Switch.Set", {"id": 0, "on": true});
}
if ((currentTemp >= (tempSetPoint + tempHysteresis)) && (switchStatus)) {
if (debug) print ("Output set OFF");
Shelly.call("Switch.Set", {"id": 0, "on": false});
}
}
}
function timerCode() {
if (verboseDebug) print("-> Timer executed.");
if (thermostatEnabled) {
// https://www.shelly-support.eu/forum/thread/19706-reading-input-and-temperature-in-a-script/
Shelly.call(
"temperature.getStatus",
{ id: 100 },
processTemperatures,
null);
}
}
if (debug) print("Start.");
Timer.set(/* miliseconds */ 30000, /* repeat? */ true, /* callback */ timerCode);