# Test for MQ-series drivers
# Ported from https://github.com/kartun83/micropython-MQ
# --------------------------------------------------
# Edited to run on PyCom devices
# Author: avsg8, (https://github.com/avsg8), 01/2024
from BaseMQ import BaseMQ
from micropython import const
from MQ7 import MQ7
import utime
pin = 'P13'
baseVoltage = 5
ro = 5.65 # if you want to calibrate it else, supply with values gotten from previous runs
class App:
#pin = 'P13'
#baseVoltage = 5
#ro = 9.654
def __init__(self, pin = pin):
self.sensor = MQ7(pinData = pin, baseVoltage = baseVoltage)
#self.sensor._ro = 0.7663 #0.2022838 # comment this line for the first run, calibrate and get the value. Then put the value here
def Run(self):
print("Calibrating")
self.sensor.calibrate(ro = ro)
print("Calibration completed")
print("Base resistance:{0}".format(self.sensor._ro))
if ro != -1:
val = self.sensor.readCarbonMonoxide()
return val
else:
while True:
print("C0: {0}".format(self.sensor.readCarbonMonoxide()))
#print("LPG: {0}".format(self.sensor.readLPG()))
#print("Methane: {0}".format(self.sensor.readMethane()))
#print("Hydrogen: {0}".format(self.sensor.readHydrogen()))
utime.sleep(5)
if __name__=="__main__":
val = App().Run()