With this app, a Z-UNO z-wave and some extra hardware, you can control your Flexit SP30 control panel.
You can control the fan level (Minimum, Normal, Maximum) and the heating (On, Off).
Use cases:
- The ventilation system is turned on for 30 minutes each morning.
- The ventilation system is turned on if the humidity in the bathroom changes more than 5 percentage within 5 minutes.
- The ventilation system is turned on if the CO2 - level is too high.
- The ventilation system is turned on from the SP30 panel (to Normal or Maximum), and then automatically turned off after 1 hour.
- Fan level status
- Heating status
- Temperature: Air from outside
- Temperature: Air to outside
- Temperature: Air to house
- Temperature: Air from house
- Power (estimated)
- Heat efficiency (%)
- Fan level changed (tokens: value, from_panel)
- Heating changed (tokens: value, from_panel)
- Air from outside temperature changed (tokens: temperature)
- Air to outside temperature changed (tokens: temperature)
- Air to house temperature changed (tokens: temperature)
- Air from house temperature changed (tokens: temperature)
- Is fan level (Minimum, Normal, Maximum)
- Is heating on / off
- Set mode (Minimum, Normal, Maximum, Normal/Heat, Maximum/Heat)
- Calibrate temperature sensors
- Fan level status report interval (s)
- Temperature report interval (s)
- Temperature report threshold (°C)
- Relay on duration (ms)
- Device enabled: enable to send status and temperature updates
- Relays enabled: enable to switch relays
- Air from outside temperature sensor calibration (°C)
- Air to outside temperature sensor calibration (°C)
- Air to house temperature sensor calibration (°C)
- Air from house temperature sensor calibration (°C
Click here for the Z-UNO firmware and information about the required hardware.
Use at your own risk. I accept no responsibility for any damages caused by using this app.
- Initial version