Notifications
You must be signed in to change notification settings - Fork 14
/
LIEBERT_GP_FLEXIBLE.MIB
409 lines (364 loc) · 14.2 KB
/
LIEBERT_GP_FLEXIBLE.MIB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
LIEBERT-GP-FLEXIBLE-MIB DEFINITIONS ::= BEGIN
IMPORTS
DisplayString
FROM SNMPv2-TC
MODULE-IDENTITY,
OBJECT-IDENTITY,
OBJECT-TYPE,
Integer32,
Unsigned32
FROM SNMPv2-SMI
lgpFlexible,
liebertFlexibleModuleReg
FROM LIEBERT-GP-REGISTRATION-MIB
;
-- =============================================================================
-- Module Identification and Registration
-- =============================================================================
liebertGlobalProductsFlexibleModule MODULE-IDENTITY
LAST-UPDATED "201305140000Z"
ORGANIZATION "Liebert Corporation"
CONTACT-INFO
"Contact: Technical Support
Postal:
Liebert Corporation
1050 Dearborn Drive
P.O. Box 29186
Columbus OH, 43229
US
Tel: +1 (800) 222-5877
E-mail: liebert.monitoring@vertivco.com
Web: www.vertivco.com
Author: Phil Ulrich"
DESCRIPTION
"The MIB module used to register Liebert Flexible related SNMP OIDs.
Copyright 2013 Liebert Corporation. All rights reserved.
Reproduction of this document is authorized on the condition
that the forgoing copyright notice is included.
This Specification is supplied 'AS IS' and Liebert Corporation
makes no warranty, either express or implied, as to the use,
operation, condition, or performance of the Specification."
REVISION "201305140000Z"
DESCRIPTION
"Initial Version"
::= { liebertFlexibleModuleReg 1 }
-- =============================================================================
-- lgpFlexible - Liebert Flexible Registrations
-- =============================================================================
-- -----------------------------------------------------------------------------
-- Flexible Basic Table
-- -----------------------------------------------------------------------------
lgpFlexibleTableCount OBJECT-TYPE
SYNTAX Unsigned32
UNITS "Count"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the number of entries in the lgpFlexibleBasicTable."
::= { lgpFlexible 10 }
lgpFlexibleBasicTable OBJECT-TYPE
SYNTAX SEQUENCE OF LgpFlexibleBasicEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains data points supported by the managed device. The
data in this table is formatted in string form. This data is also
available in numerical form in the augmented
lgpFlexibleExtendedTable.
In this table, the row indexing is not necessarily sequential and
leads to a sparsely populated table."
::= { lgpFlexible 20 }
lgpFlexibleBasicEntry OBJECT-TYPE
SYNTAX LgpFlexibleBasicEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This entry defines the columns to be populated in the
'lgpFlexibleBasicTable'."
INDEX
{
IMPLIED lgpFlexibleEntryIndex
}
::= { lgpFlexibleBasicTable 1 }
LgpFlexibleBasicEntry ::= SEQUENCE
{
lgpFlexibleEntryIndex OBJECT IDENTIFIER,
lgpFlexibleEntryDataLabel DisplayString,
lgpFlexibleEntryValue DisplayString,
lgpFlexibleEntryUnitsOfMeasure DisplayString
}
lgpFlexibleEntryIndex OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is the index which defines a specific row in the
lgpFlexibleBasicTable. Each row index is associated with a unique
data point ID which fixes the data point to its permanent location
in the table."
::= { lgpFlexibleBasicEntry 1 }
lgpFlexibleEntryDataLabel OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A short description of the data reported in this row."
::= { lgpFlexibleBasicEntry 10 }
lgpFlexibleEntryValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A string representation of any data available. This is the
preferred method of data access, since this will give fully
scaled data for both integer and floating point data, in addition
to textual data. If this string column cannot be used, then
columns in the lgpFlexibleExtendedTable must be used in order
to get a fully scaled version of integer data."
::= { lgpFlexibleBasicEntry 20 }
lgpFlexibleEntryUnitsOfMeasure OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unit of measure that the value will be presented in. This is
not populated when the data does not have a unit of measure
associated with it."
::= { lgpFlexibleBasicEntry 30 }
-- -----------------------------------------------------------------------------
-- Flexible Extended Table
-- -----------------------------------------------------------------------------
lgpFlexibleExtendedTable OBJECT-TYPE
SYNTAX SEQUENCE OF LgpFlexibleExtendedEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains data points supported by the managed device. This
table augments the lgpFlexibleBasicTable, providing additional
information that may be relevant to advanced users. Values presented
in string format in the lgpFlexibleBasicTable table are also available in
numeric form in this table.
Since the lgpFlexibleBasicTable and this table are both indexed by
lgpFlexibleEntryIndex, data applicable to a specific data point can be
found in both tables at the same index."
::= { lgpFlexible 30 }
lgpFlexibleExtendedEntry OBJECT-TYPE
SYNTAX LgpFlexibleExtendedEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This entry defines the columns to be populated in the
'lgpFlexibleExtendedTable'."
AUGMENTS { lgpFlexibleBasicEntry }
::= { lgpFlexibleExtendedTable 1 }
LgpFlexibleExtendedEntry ::= SEQUENCE
{
lgpFlexibleEntryIntegerValue Integer32,
lgpFlexibleEntryUnsignedIntegerValue Unsigned32,
lgpFlexibleEntryDecimalPosition Unsigned32,
lgpFlexibleEntryDataType INTEGER,
lgpFlexibleEntryAccessibility INTEGER,
lgpFlexibleEntryUnitsOfMeasureEnum INTEGER,
lgpFlexibleEntryDataDescription DisplayString
}
lgpFlexibleEntryIntegerValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the data point value formatted as a signed integer. This
column is populated only for numerical data points whose type
requires a signed value.
To convert this value to the units indicated in the units of
measure columns (lgpFlexibleEntryUnitsOfMeasure or
lgpFlexibleEntryUnitsOfMeasureEnum), divide this value
by 10^n, where n is the value from the
lgpFlexibleEntryDecimalPosition column.
For data points that are writable (as designated by the
lgpFlexibleEntryAccessibility column), the inverse
calculation must done. The desired value must be multiplied by
10^n before it is written to this column, where n is the value
from the lgpFlexibleEntryDecimalPosition column."
::= { lgpFlexibleExtendedEntry 10 }
lgpFlexibleEntryUnsignedIntegerValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the data point value formatted as an unsigned integer. This
column is populated only for numerical data points whose type
does not require a signed value.
To convert this value to the units indicated in the units of
measure columns (lgpFlexibleEntryUnitsOfMeasure or
lgpFlexibleEntryUnitsOfMeasureEnum), divide this value
by 10^n, where n is the value from the
lgpFlexibleEntryDecimalPosition column.
For data points that are writable (as designated by the
lgpFlexibleEntryAccessibility column), the inverse
calculation must done. The desired value must be multiplied by
10^n before it is written to this column, where n is the value
from the lgpFlexibleEntryDecimalPosition column."
::= { lgpFlexibleExtendedEntry 20 }
lgpFlexibleEntryDecimalPosition OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is a power of ten divider needed to convert values from the
signed and unsigned integer columns
(lgpFlexibleEntryIntegerValue or
lgpFlexibleEntryUnsignedIntegerValue) to floating
point values. This essentially tells how many positions to move
the decimal point to the left.
To convert the integer values to the units indicated in the units
of measure columns (lgpFlexibleEntryUnitsOfMeasure or
lgpFlexibleEntryUnitsOfMeasureEnum), divide the
integer value by 10^n, where n is the value from this column.
For data points that are writable (as designated by the
lgpFlexibleEntryAccessibility column), the inverse
calculation must done. The desired value must be multiplied by
10^n before it is written to the signed or unsigned integer
columns."
::= { lgpFlexibleExtendedEntry 30 }
lgpFlexibleEntryDataType OBJECT-TYPE
SYNTAX INTEGER
{
not-specified(0),
int16(1),
uint16(2),
int32(3),
uint32(4),
text(5),
enum(6),
event16(7),
event32(8),
ipv4(9),
time32(10)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The format that the data will appear as. This can be used to
determine which field the numerical data will appear in. Data of
type int16 and int32 will appear in the column
lgpFlexibleEntryIntegerValue. Data of type uint16,
uint32, and enum, will appear in the column
lgpFlexibleEntryUnsignedIntegerValue."
::= { lgpFlexibleExtendedEntry 40 }
lgpFlexibleEntryAccessibility OBJECT-TYPE
SYNTAX INTEGER
{
not-specified(0),
readonly(1),
writeonly(2),
readwrite(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This describes the read/write access that is available for the
data in the row."
::= { lgpFlexibleExtendedEntry 50 }
lgpFlexibleEntryUnitsOfMeasureEnum OBJECT-TYPE
SYNTAX INTEGER
{
not-specified(0),
milliSeconds(4096),
seconds(4097),
minutes(4098),
hours(4099),
voltsAcRms(4100),
milliVoltsAcRms(4101),
voltsDc(4102),
milliVoltsDc(4103),
voltsPeak(4104),
voltsPeakToPeak(4105),
ampsAcRms(4106),
milliAmpsAcRms(4107),
ampsDc(4108),
milliAmpsDc(4109),
voltAmps(4110),
kiloVoltAmps(4111),
voltAmpsReactive(4112),
kVAReactive(4113),
watts(4114),
kiloWatts(4115),
wattHours(4116),
kiloWattHour(4117),
ampDcHours(4118),
hertz(4119),
milliHertz(4120),
kiloHertz(4121),
megaHertz(4122),
gigaHertz(4123),
percent(4124),
degC(4125),
degCDelta(4126),
degF(4127),
degFDelta(4128),
psi(4129),
pascal(4130),
psia(4131),
relativeHumidity(4132),
thd(4133),
days(4134),
phase(4135),
microOhms(4136),
milliOhms(4137),
ohms(4138),
kiloOhms(4139),
megaOhms(4140),
bars(4141),
rpm(4142),
bytes(4143),
kilobytes(4144),
megabytes(4145),
gigabytes(4146),
terabytes(4147),
voltAmpHours(4148),
kiloVoltAmpHours(4149),
vaReactiveHours(4150),
kVAReactiveHours(4151),
meter(4152),
feet(4153),
cms(4154),
cmh(4155),
cfs(4156),
cfm(4157),
lpm(4158),
gpmUk(4159),
gpmUs(4160),
absoluteHumidity(4161),
kilograms(4162),
cubicMeters(4163),
btu(4164),
torrs(4165),
millitorrs(4166),
pounds(4167),
mps(4168),
fpm(4169),
liter(4170),
gallonUs(4171),
gallonUk(4172),
lps(4173),
mho(4174),
siemensCm(4175),
weeks(4176),
inWC(4177),
btuHours(4178)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unit of measurement that the value will be in."
::= { lgpFlexibleExtendedEntry 60 }
lgpFlexibleEntryDataDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A description of the data reported in this row. This is generally
longer and more thorough than the simple label described by
lgpFlexibleEntryDataLabel."
::= { lgpFlexibleExtendedEntry 70 }
END