forked from easybotics/esphome-ruixu-bms
-
Notifications
You must be signed in to change notification settings - Fork 0
/
esp32-example.yaml
150 lines (138 loc) · 3.87 KB
/
esp32-example.yaml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
substitutions:
name: seplos-bms
device_description: "Monitor a Seplos BMS via RS485"
external_components_source: github://syssi/esphome-seplos-bms@main
tx_pin: GPIO4
rx_pin: GPIO5
esphome:
name: ${name}
comment: ${device_description}
min_version: 2024.6.0
project:
name: "syssi.esphome-seplos-bms"
version: 1.2.0
esp32:
board: wemos_d1_mini32
external_components:
- source: ${external_components_source}
refresh: 0s
wifi:
ssid: !secret wifi_ssid
password: !secret wifi_password
ota:
platform: esphome
logger:
level: DEBUG
# If you use Home Assistant please remove this `mqtt` section and uncomment the `api` component!
# The native API has many advantages over MQTT: https://esphome.io/components/api.html#advantages-over-mqtt
mqtt:
broker: !secret mqtt_host
username: !secret mqtt_username
password: !secret mqtt_password
id: mqtt_client
# api:
uart:
id: uart_0
# Please set the default baudrate of your Seplos BMS model here. It's sometimes 19200 baud instead of 9600.
baud_rate: 9600
tx_pin: ${tx_pin}
rx_pin: ${rx_pin}
# The increased RX buffer size is important because
# the full BMS response must fit into the buffer
rx_buffer_size: 384
seplos_modbus:
id: modbus0
uart_id: uart_0
rx_timeout: 150ms
seplos_bms:
id: bms0
# Dip switch configuration of a single pack setup / address 0x0
# 8 7 6 5 4 3 2 1
# off, off, off, off, off, off, off, off
address: 0x00
# Known protocol versions: 0x20 (Seplos), 0x26 (Boqiang)
protocol_version: 0x20
seplos_modbus_id: modbus0
update_interval: 10s
sensor:
- platform: seplos_bms
min_cell_voltage:
name: "${name} min cell voltage"
max_cell_voltage:
name: "${name} max cell voltage"
min_voltage_cell:
name: "${name} min voltage cell"
max_voltage_cell:
name: "${name} max voltage cell"
delta_cell_voltage:
name: "${name} delta cell voltage"
average_cell_voltage:
name: "${name} average cell voltage"
cell_voltage_1:
name: "${name} cell voltage 1"
cell_voltage_2:
name: "${name} cell voltage 2"
cell_voltage_3:
name: "${name} cell voltage 3"
cell_voltage_4:
name: "${name} cell voltage 4"
cell_voltage_5:
name: "${name} cell voltage 5"
cell_voltage_6:
name: "${name} cell voltage 6"
cell_voltage_7:
name: "${name} cell voltage 7"
cell_voltage_8:
name: "${name} cell voltage 8"
cell_voltage_9:
name: "${name} cell voltage 9"
cell_voltage_10:
name: "${name} cell voltage 10"
cell_voltage_11:
name: "${name} cell voltage 11"
cell_voltage_12:
name: "${name} cell voltage 12"
cell_voltage_13:
name: "${name} cell voltage 13"
cell_voltage_14:
name: "${name} cell voltage 14"
cell_voltage_15:
name: "${name} cell voltage 15"
cell_voltage_16:
name: "${name} cell voltage 16"
temperature_1:
name: "${name} temperature 1"
temperature_2:
name: "${name} temperature 2"
temperature_3:
name: "${name} temperature 3"
temperature_4:
name: "${name} temperature 4"
temperature_5:
name: "${name} environment temperature"
temperature_6:
name: "${name} mosfet temperature"
total_voltage:
name: "${name} total voltage"
current:
name: "${name} current"
power:
name: "${name} power"
charging_power:
name: "${name} charging power"
discharging_power:
name: "${name} discharging power"
residual_capacity:
name: "${name} residual capacity"
battery_capacity:
name: "${name} battery capacity"
rated_capacity:
name: "${name} rated capacity"
state_of_charge:
name: "${name} state of charge"
charging_cycles:
name: "${name} charging cycles"
state_of_health:
name: "${name} state of health"
port_voltage:
name: "${name} port voltage"