MySensors/ Homie Bridge

This project will take an existing MQTT based MySensors network and act as its controller.

It will expose the network via the Homie convention, again on MQTT.

This provides bidirectional access, and auto detection via the Homie convention for automation servers that support Homie, but do not support MySensors via the MQTT gateway.

Quick Start

Download this repo.

Edit the configuration file config.json to set your MQTT broker.

Currently, this is the same one that your MySensors gateway is connected, and the one where a matching Homie network will be created by the adatper.

> yarn
> yarn start

Then, (re) start your MySensors nodes to have them detected and republished using the Homie convention

You will need an automation server of some sort that understand Homie.

I have used this successfully with OpenHab 3 and the MQTT Binding, which has Homie support built in.

An example S_BINARY/ relay control arduino sketch that runs with a RF-NANO/ RF24 based MySensor setup is in the examples folder.

State File

See mysensors-homie.json

[
  {
    "nodeId": "2",
    "repeater": true,
    "name": "TestDevice",
    "sensors": [
      {
        "id": "1",
        "type": "S_BINARY"
      }
    ]
  },
  {
    "nodeId": "1",
    "repeater": true,
    "name": "Relay+button",
    "sensors": [
      {
        "id": "1",
        "type": "S_BINARY"
      }
    ]
  }
]

Adding support for a new MySensors Type

As below, not all MySensors types are fully supported.

The full list of MySensors types is at https://www.mysensors.org/download/serial_api_20

Create a new handler in src/type-handler/[name_of_type].ts (for example s_binary.ts)

export function setupSBinary(homieNode: HomieNode, node: MSNode, sensor: Sensor) {

    sensor.handler = async cmd => {     (1)
        homieNode.setProperty(sensor.type + "_" + sensor.id).setRetained(true).send(cmd.payload == "1" ? "true" : "false");
    }

    (2)
    homieNode.advertise(sensor.type + "_" + sensor.id).setName('on/off').setDatatype('boolean').settable(function (range: any, value: any) {
        console.log(`[homie] NODE ${node.nodeId}: Switching ${sensor.id} on/ off ` + value)

        return sendMySensorsCommand({   (3)
            nodeId: node.nodeId,
            childSensorId: sensor.id,
            command: "SET",
            ack: "0",
            type: "V_STATUS",
            payload: value == "true" ? "1" : "0"
        }, client)
    });
}
  1. Register a handler against the sensor. All MySensors commands that are received for this sensor will be passed to this handler.

  2. Advertise the sensor on the Homie network against the auto created Homie Node. This is the API - https://github.com/microclimates/homie-device

  3. When a settable Homie property is set, you will receive messages for it. These can be translated to MySensors commands here.

Supported features

This is Work In Progress

Stores the current MySensors network in a local state file (mysensors-homie.json), will re-advertise it on startup.

Controller will give out new MySensors IDs, and register the existence of static/ existing IDs.

All values below are the same as in the MySensors Serial API 2.0 https://www.mysensors.org/download/serial_api_20

Table 1. Command Types

ID

TYPE

SUPPORTED

0

PRESENT

1

SET

2

REQ

3

INTERNAL

4

STREAM

Table 2. Presentation Types

ID

TYPE

SUPPORTED

0

S_DOOR

1

S_MOTION

2

S_SMOKE

3

S_BINARY

4

S_DIMMER

5

S_COVER

6

S_TEMP

7

S_HUM

8

S_BARO

9

S_WIND

10

S_RAIN

11

S_UV

12

S_WEIGHT

13

S_POWER

14

S_HEATER

15

S_DISTANCE

16

S_LIGHT_LEVEL

17

S_ARDUINO_NODE

18

S_ARDUINO_REPEATER_NODE

19

S_LOCK

20

S_IR

21

S_WATER

22

S_AIR_QUALITY

23

S_CUSTOM

24

S_DUST

25

S_SCENE_CONTROLLER

26

S_RGB_LIGHT

27

S_RGBW_LIGHT

28

S_COLOR_SENSOR

29

S_HVAC

30

S_MULTIMETER

31

S_SPRINKLER

32

S_WATER_LEAK

33

S_SOUND

34

S_VIBRATION

35

S_MOISTURE

36

S_INFO

37

S_GAS

38

S_GPS

39

S_WATER_QUALITY

Table 3. Set/ Req Types

ID

TYPE

From Sensor

To Sensor

0

V_TEMP

1

V_HUM

2

V_STATUS

3

V_PERCENTAGE

4

V_PRESSURE

5

V_FORECAST

6

V_RAIN

7

V_RAINRATE

8

V_WIND

9

V_GUST

10

V_DIRECTION

11

V_UV

12

V_WEIGHT

13

V_DISTANCE

14

V_IMPEDANCE

15

V_ARMED

16

V_TRIPPED

17

V_WATT

18

V_KWH

19

V_SCENE_ON

20

V_SCENE_OFF

21

V_HVAC_FLOW_STATE

22

V_HVAC_SPEED

23

V_LIGHT_LEVEL

24

V_VAR1

25

V_VAR2

26

V_VAR3

27

V_VAR4

28

V_VAR5

29

V_UP

30

V_DOWN

31

V_STOP

32

V_IR_SEND

33

V_IR_RECEIVE

34

V_FLOW

35

V_VOLUME

36

V_LOCK_STATUS

37

V_LEVEL

38

V_VOLTAGE

39

V_CURRENT

40

V_RGB

41

V_RGBW

42

V_ID

43

V_UNIT_PREFIX

44

V_HVAC_SETPOINT_COOL

45

V_HVAC_SETPOINT_HEAT

46

V_HVAC_FLOW_MODE

47

V_TEXT

48

V_CUSTOM

49

V_POSITION

50

V_IR_RECORD

51

V_PH

52

V_ORP

53

V_EC

54

V_VAR

55

V_VA

56

V_POWER_FACTOR

Table 4. Internal Types

ID

TYPE

SUPPORTED

0

I_BATTERY_LEVEL

1

I_TIME

2

I_VERSION

3

I_ID_REQUEST

4

I_ID_RESPONSE

5

I_INCLUSION_MODE

6

I_CONFIG

7

I_FIND_PARENT

8

I_FIND_PARENT_RESPONSE

9

I_LOG_MESSAGE

10

I_CHILDREN

11

I_SKETCH_NAME

12

I_SKETCH_VERSION

13

I_REBOOT

14

I_GATEWAY_READY

15

I_SIGNING_PRESENTATION

16

I_NONCE_REQUEST

17

I_NONCE_RESPONSE

18

I_HEARTBEAT_REQUEST

19

I_PRESENTATION

20

I_DISCOVER_REQUEST

21

I_DISCOVER_RESPONSE

22

I_HEARTBEAT_RESPONSE

23

I_LOCKED

24

I_PING

25

I_PONG

26

I_REGISTRATION_REQUEST

27

I_REGISTRATION_RESPONSE

28

I_DEBUG

29

I_SIGNAL_REPORT_REQUEST

30

I_SIGNAL_REPORT_REVERSE

31

I_SIGNAL_REPORT_RESPONSE

32

I_PRE_SLEEP_NOTIFICATION

33

I_POST_SLEEP_NOTIFICATION

Stream Commands

Stream is not supported

Included Software

Homie device code derived from this - https://github.com/microclimates/homie-device

  • Converted to typescript

  • Shared MQTT connection