Skip to content

UPS On UPS Completed

Vrinda edited this page Mar 27, 2023 · 1 revision

Overview

A UPS On UPS Completed rule is typically used for use cases explained as part of Double Reading UPS wherein a new a Unified Procedure Step (UPS) is created only when previous UPS records are COMPLETED.

Configuration

A rule for UPS on store may be configured either on :

  • Archive Device level : Go to Configuration page -> Devices tab -> dcm4chee-arc -> Device Extension -> Archive Device Extension -> Child Objects -> UPS on UPS Completed Rules and add one. This rule shall be applied to UPS managed by any AE.

  • Archive Network AE level : Go to Configuration page -> Devices tab -> dcm4chee-arc -> Child Objects -> Network AEs -> DCM4CHEE -> Network AE Extension -> Archive Network AE Extension -> Child Objects -> UPS on UPS Completed Rules and add one. This rule shall be applied to UPS managed by this AE.

  • A Procedure Step Label is a mandatory field and must always have a value set to it.

  • To process workitems after a certain delay set Scheduled Procedure Step Start DateTime Delay. If no value is set, the created UPS is processed immediately once the UPS Processing Polling Interval is reached and if a matching UPS Processing Rule is also configured. (Pre-configured default value for UPS Processing Polling Interval is set to PT1M)

Clone this wiki locally