Notifications
You must be signed in to change notification settings - Fork 4
/
plugin.py
573 lines (520 loc) · 29.8 KB
/
plugin.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
# DSC EnvisaLink 3 & 4 Alarm interface Plugin
#
# Author: Dnpwwo, 2018
#
"""
<plugin key="EnvisaLink" name="DSC Alarm via EnvisaLink" author="dnpwwo" version="2.1.8" wikilink="https://github.com/dnpwwo/Domoticz-DSCEnvisalink-Plugin" externallink="http://www.eyezon.com/?page_id=176">
<description>
<h2>EnvisaLink 3 & 4 Alarm interface for DSC Alarms</h2><br/>
<h3>Features</h3>
<ul style="list-style-type:square">
<li>Shows Zone and Partition status in Domoticz</li>
<li>Can be integrated with the Domoticz Security Panel to allow Arm & Disarm operations from Domoticz</li>
<li>Bypassed Zones shown with Red banner in Domoticz</li>
</ul>
<h3>Devices</h3>
<ul style="list-style-type:square">
<li>Zones - Contact device per zone that show Open/Closed status. These can be changed to 'Motion' devices in the Device Edit page and they will show On/Off (recommend setting an Off Delay otherwise activity is rarely seen in the Web UI)</li>
<li>Partition - Alert per partition that shows partition state, useful if you don't want to use the Security Panel integration or you have more than one partition.</li>
<li>Command Output - Contact device for each Command Output/Partition combination seen. The DSC only reports activation so an Off Delay must exist for the device to reset).</li>
<li>Security Panel - Optionally creates a Security Panel device that allows arming and disarming via Domoticz.</li>
</ul>
</description>
<params>
<param field="Address" label="IP Address" width="200px" required="true" default="127.0.0.1"/>
<param field="Port" label="Port" width="30px" required="true" default="4025"/>
<param field="Password" label="Envisalink Password" width="200px" required="true" default="" password="true"/>
<param field="Mode1" label="Max. Partitions" width="50px">
<options>
<option label="1" value="1" default="true"/>
<option label="2" value="2" />
<option label="3" value="3" />
<option label="4" value="4" />
<option label="5" value="5" />
<option label="6" value="6" />
<option label="7" value="7" />
<option label="8" value="8" />
</options>
</param>
<param field="Mode2" label="Max. Zones" width="50px">
<options>
<option label="1" value="1"/>
<option label="2" value="2" />
<option label="3" value="3" />
<option label="4" value="4" />
<option label="5" value="5" />
<option label="6" value="6" default="true"/>
<option label="7" value="7" />
<option label="8" value="8" />
<option label="9" value="9" />
<option label="10" value="10" />
<option label="11" value="11" />
<option label="12" value="12" />
<option label="13" value="13" />
<option label="14" value="14" />
<option label="15" value="15" />
<option label="16" value="16" />
<option label="17" value="17" />
<option label="18" value="18" />
<option label="19" value="19" />
<option label="20" value="20" />
<option label="21" value="21" />
<option label="22" value="22" />
<option label="23" value="23" />
<option label="24" value="24" />
<option label="25" value="25" />
<option label="26" value="26" />
<option label="27" value="27" />
<option label="28" value="28" />
<option label="29" value="29" />
<option label="30" value="30" />
<option label="31" value="31" />
<option label="32" value="32" />
<option label="33" value="33" />
<option label="34" value="34" />
<option label="35" value="35" />
<option label="36" value="36" />
<option label="37" value="37" />
<option label="38" value="38" />
<option label="39" value="39" />
<option label="40" value="40" />
<option label="41" value="41" />
<option label="42" value="42" />
<option label="43" value="43" />
<option label="44" value="44" />
<option label="45" value="45" />
<option label="46" value="46" />
<option label="47" value="47" />
<option label="48" value="48" />
<option label="49" value="49" />
<option label="50" value="50" />
<option label="51" value="51" />
<option label="52" value="52" />
<option label="53" value="53" />
<option label="54" value="54" />
<option label="55" value="55" />
<option label="56" value="56" />
<option label="57" value="57" />
<option label="58" value="58" />
<option label="59" value="59" />
<option label="60" value="60" />
<option label="61" value="61" />
<option label="62" value="62" />
<option label="63" value="63" />
<option label="64" value="64" />
</options>
</param>
<param field="Mode3" label="Integrated Security Panel" width="75px">
<options>
<option label="True" value="True" default="True"/>
<option label="False" value="False" />
</options>
</param>
<param field="Mode4" label="Alarm Passcode" width="75px" default="" password="true" />
<param field="Mode5" label="Time Out Lost Devices" width="75px">
<options>
<option label="True" value="True" default="True"/>
<option label="False" value="False" />
</options>
</param>
<param field="Mode6" label="Debug" width="150px">
<options>
<option label="None" value="0" default="true" />
<option label="Python Only" value="2"/>
<option label="Basic Debugging" value="62"/>
<option label="Basic+Messages" value="126"/>
<option label="Connections Only" value="16"/>
<option label="Connections+Python" value="18" default="true" />
<option label="Connections+Queue" value="144"/>
<option label="All" value="-1"/>
</options>
</param>
</params>
</plugin>
"""
import Domoticz
from dsc_envisalinkdefs import *
from alarm_state import AlarmState
from datetime import datetime
import sys
import re
import json
ZONE_BASE = 0
SECURITY_PANEL = 100
PARTITION_BASE = 100 # First partition will be this + partition number so 101
OUTPUT_BASE = 100 # Device will be number will be this + 10*partition + output. i.e partition 1 output 2 = Device 112
class BasePlugin:
alarmConn = None
alarmState = None
nextConnect = 3
heartbeatInterval = 20
nextTimeSync = 0
oustandingPings = 0
def onStart(self):
if Parameters["Mode6"] != "0":
Domoticz.Debugging(int(Parameters["Mode6"]))
DumpConfigToLog()
self.alarmState = AlarmState.get_initial_alarm_state(int(Parameters["Mode2"]), int(Parameters["Mode1"]))
self.alarmConn = Domoticz.Connection(Name="EnvisaLink", Transport="TCP/IP", Protocol="Line", Address=Parameters["Address"], Port=Parameters["Port"])
self.alarmConn.Connect()
Domoticz.Heartbeat(self.heartbeatInterval)
def onConnect(self, Connection, Status, Description):
if (Status == 0):
Domoticz.Log("Connected successfully to: "+Connection.Address+":"+Connection.Port)
self.nextTimeSync = 0
else:
Domoticz.Log("Failed to connect ("+str(Status)+") to: "+Connection.Address+":"+Connection.Port)
for Key in Devices:
UpdateDevice(Key, 0, Devices[Key].sValue, 1)
def onMessage(self, Connection, Data):
global evl_ResponseTypes
strData = Data.decode("utf-8", "ignore").strip()
if (ValidChecksum(strData)):
dataoffset = 0
if re.match('\d\d:\d\d:\d\d\s', strData):
dataoffset = dataoffset + 9
code = strData[dataoffset:dataoffset+3]
data = strData[dataoffset+3:][:-2]
if code in evl_ResponseTypes:
try:
handlerFunc = getattr(self, "handle_"+evl_ResponseTypes[code]['handler'], self.notHandled)
result = handlerFunc(code, data)
# Sync Devices to Alarm state
for zone in self.alarmState['zone']:
if (not ZONE_BASE+zone in Devices):
Domoticz.Device(Name="Zone "+str(ZONE_BASE+zone), Unit=ZONE_BASE+zone, Type=244, Subtype=73, Switchtype=2).Create()
sValue = 'Closed'
if self.alarmState['zone'][zone]['status']['open']: sValue='Open'
if self.alarmState['zone'][zone]['status']['bypass']: sValue='Bypass'
if self.alarmState['zone'][zone]['status']['tamper']: sValue='Tamper'
UpdateDevice(ZONE_BASE+zone, \
1 if self.alarmState['zone'][zone]['status']['open'] else 0, \
sValue, \
self.alarmState['zone'][zone]['status']['bypass'])
for part in self.alarmState['partition']:
if (not PARTITION_BASE+part in Devices):
Domoticz.Device(Name="Partition "+str(part), Unit=PARTITION_BASE+part, TypeName='Alert').Create()
nValue = 1 if self.alarmState['partition'][part]['status']['ready'] else 2
if self.alarmState['partition'][part]['status']['trouble']: nValue=2
if self.alarmState['partition'][part]['status']['alarm']: nValue=3
UpdateDevice(PARTITION_BASE+part, nValue, \
self.alarmState['partition'][part]['status']['alpha'], \
self.alarmState['partition'][part]['status']['trouble'])
if Parameters["Mode3"] != "False":
if (not SECURITY_PANEL in Devices):
#Domoticz.Device(Name="Security Panel", Unit=SECURITY_PANEL, TypeName="Security Panel").Create()
Domoticz.Device(Name="Security Panel", Unit=SECURITY_PANEL, Type=32, Subtype=131).Create()
Domoticz.Log("Created Domoticz integrated Security Panel device for partition 1.")
nValue=0 # sStatusNormal
if self.alarmState['partition'][1]['status']['alarm']: nValue=2 # sStatusAlarm
if self.alarmState['partition'][1]['status']['armed_away']: nValue=9 # sStatusArmAway
if self.alarmState['partition'][1]['status']['armed_stay']: nValue=11 # sStatusArmHome
if self.alarmState['partition'][1]['status']['trouble']: nValue=nValue+128 # sStatusNormalTamper or sStatusAlarmTamper
UpdateDevice(SECURITY_PANEL, nValue, "", self.alarmState['partition'][part]['status']['trouble'])
except AttributeError:
Domoticz.Error(str.format("No handler exists for code: {0}. Skipping.", evl_ResponseTypes[code]['handler']))
except KeyError as err:
Domoticz.Error("No handler configured for '"+str(code)+"' code.")
except TypeError as e:
Domoticz.Error("Type error: {0}".format(e))
else:
self.notHandled(code, data)
else:
Domoticz.Error("EnvisaLink returned invalid message: '"+str(strData)+"'. Checksums: Calculated "+str(checkSum)+" and Original "+str(int(origChecksum,16)))
def onSecurityEvent(self, Unit, Level, Description):
Domoticz.Status("onSecurityEvent called for Level " + str(Level) + ": Description '" + str(Description) + "', Connected: " + str(self.alarmConn.Connected()))
# Multiple events can be passed for the same action, e.g during arming 1 event when requested, 1 event after exit timer counts to 0
if (Level == 0): # Disarm
if ((self.alarmState['partition'][1]['status']['armed_stay'] == True) or (self.alarmState['partition'][1]['status']['armed_away'] == True)):
Domoticz.Status("Requesting partition Disarm")
self.alarmConn.Send(CreateChecksum(evl_Commands['Disarm']+'1'+Parameters["Mode4"]))
elif (Level == 1): # Arm Stay
if ((self.alarmState['partition'][1]['status']['armed_stay'] == False) and (self.alarmState['partition'][1]['status']['armed_away'] == False)):
Domoticz.Status("Requesting partition Armed Stay")
self.alarmConn.Send(CreateChecksum(evl_Commands['ArmStay']+'1'))
elif (Level == 2): # Arm Away
if ((self.alarmState['partition'][1]['status']['armed_stay'] == False) and (self.alarmState['partition'][1]['status']['armed_away'] == False)):
Domoticz.Status("Requesting partition Armed Away")
self.alarmConn.Send(CreateChecksum(evl_Commands['ArmAway']+'1'))
else:
Domoticz.Error("Security Event contains unknown data: '"+str(Level)+"' with description: '"+Description+"'")
def onCommand(self, Unit, Command, Level, Hue):
Domoticz.Debug("onCommand called for Unit " + str(Unit) + ": Parameter '" + str(Command) + "', Level: " + str(Level) + ", Connected: " + str(self.alarmConn.Connected()))
Command = Command.strip()
action, sep, params = Command.partition(' ')
action = action.capitalize()
def onNotification(self, Name, Subject, Text, Status, Priority, Sound, ImageFile):
Domoticz.Log("Notification: " + Name + "," + Subject + "," + Text + "," + Status + "," + str(Priority) + "," + Sound + "," + ImageFile)
def onHeartbeat(self):
try:
if (self.alarmConn.Connected()):
if (self.nextTimeSync <= 0):
now = datetime.now()
message = '{:02}{:02}{:02}{:02}{:02}'.format(now.hour, now.minute, now.month, now.day, now.year-2000)
Domoticz.Log("Sending time synchronization command ('"+message+"')")
self.alarmConn.Send(CreateChecksum(evl_Commands['TimeSync']+message))
self.nextTimeSync = int(3600/self.heartbeatInterval) # sync time hourly
else:
if (self.oustandingPings <= 0):
self.oustandingPings = int(300/self.heartbeatInterval) # heartbeat every 5 minutes
self.alarmConn.Send(CreateChecksum(evl_Commands['KeepAlive']))
self.nextTimeSync = self.nextTimeSync - 1
self.oustandingPings = self.oustandingPings - 1
elif (self.alarmConn.Connecting() != True):
Domoticz.Log("Alarm not connected, requesting re-connect.")
self.alarmConn.Connect()
return True
except:
Domoticz.Log("Unhandled exception in onHeartbeat, forcing disconnect.")
self.alarmConn.Disconnect()
def onDisconnect(self, Connection):
Domoticz.Log("Device has disconnected")
if Parameters["Mode5"] != "False":
for Device in Devices:
UpdateDevice(Device, Devices[Device].nValue, Devices[Device].sValue, 1)
return
def onStop(self):
Domoticz.Log("onStop called")
return True
def handle_zone_state_change(self, code, data):
"""Event 601-610."""
parse = re.match('^[0-9]{3,4}$', data)
if parse:
zoneNumber = int(data[-3:])
if (zoneNumber <= int(Parameters["Mode2"])):
self.alarmState['zone'][zoneNumber]['status'].update(evl_ResponseTypes[code]['status'])
Domoticz.Debug(str.format("[zone {0}] state has updated: {1}", zoneNumber, json.dumps(evl_ResponseTypes[code]['status'])))
else:
Domoticz.Debug(str.format("[zone {0}] state change ignored, invalid zone number.", zoneNumber))
return zoneNumber
else:
Domoticz.Error("Invalid data ("+data+") has been passed in the zone update.")
def handle_zone_timer_dump(self, code, data):
parse = re.match('^[0-9A-F]{2}$', data)
try:
Domoticz.Debug(str.format("Message: '{0}' with data: {1}", evl_ResponseTypes[code]['name'], data))
except:
Domoticz.Error("zone_timer_dump error: '"+code+"' command, data: "+data)
def handle_zone_bypass_update(self, code, data):
"""Event 616, Bypassed Zones Bit field Dump."""
parse = re.match('^[0-9A-F]{2}$', data)
Domoticz.Debug(str.format("Message: '{0}' with data: {1}", evl_ResponseTypes[code]['name'], data))
allBypasses = [data[i:i+2] for i in range(0, len(data), 2)]
zoneOffset = 0
maxZone = int(Parameters["Mode2"])
for bypasses in allBypasses:
mask = int(bypasses,16)
if (zoneOffset+1 <= maxZone): self.alarmState['zone'][zoneOffset+1]['status'].update({'bypass' : (mask & 1) > 0})
if (zoneOffset+2 <= maxZone): self.alarmState['zone'][zoneOffset+2]['status'].update({'bypass' : (mask & 2) > 0})
if (zoneOffset+3 <= maxZone): self.alarmState['zone'][zoneOffset+3]['status'].update({'bypass' : (mask & 4) > 0})
if (zoneOffset+4 <= maxZone): self.alarmState['zone'][zoneOffset+4]['status'].update({'bypass' : (mask & 8) > 0})
if (zoneOffset+5 <= maxZone): self.alarmState['zone'][zoneOffset+5]['status'].update({'bypass' : (mask & 16) > 0})
if (zoneOffset+6 <= maxZone): self.alarmState['zone'][zoneOffset+6]['status'].update({'bypass' : (mask & 32) > 0})
if (zoneOffset+7 <= maxZone): self.alarmState['zone'][zoneOffset+7]['status'].update({'bypass' : (mask & 64) > 0})
if (zoneOffset+8 <= maxZone): self.alarmState['zone'][zoneOffset+8]['status'].update({'bypass' : (mask & 128) > 0})
zoneOffset = zoneOffset + 8
if (zoneOffset > maxZone): break
def handle_partition_state_change(self, code, data):
"""Event 650-674, 652 is an exception, because 2 bytes are passed for partition and zone type."""
partitionNumber = int(data[0])
if (partitionNumber <= int(Parameters["Mode1"])):
if code == '652':
parse = re.match('^[0-9]{2}$', data)
if parse:
self.alarmState['partition'][partitionNumber]['status'].update(evl_ArmModes[data[1]]['status'])
Domoticz.Debug(str.format("[partition {0}] state has updated: {1}", partitionNumber, json.dumps(evl_ArmModes[data[1]]['status'])))
return partitionNumber
else:
Domoticz.Error("Invalid data ("+data+") has been passed when arming the alarm.")
else:
parse = re.match('^[0-9]+$', data)
if parse:
self.alarmState['partition'][partitionNumber]['status'].update(evl_ResponseTypes[code]['status'])
Domoticz.Debug(str.format("[partition {0}] state has updated: {1}", partitionNumber, json.dumps(evl_ResponseTypes[code]['status'])))
'''Log the user who last armed or disarmed the alarm'''
if code == '700':
lastArmedBy = {'last_armed_by_user': int(data[1:5])}
self.alarmState['partition'][partitionNumber]['status'].update(lastArmedBy)
elif code == '750':
lastDisarmedBy = {'last_disarmed_by_user': int(data[1:5])}
self.alarmState['partition'][partitionNumber]['status'].update(lastDisarmedBy)
return partitionNumber
else:
Domoticz.Error("Invalid data ("+data+") has been passed in the partition update.")
else:
Domoticz.Debug(str.format("[partition {0}] state change ignored, invalid partition number.", partitionNumber))
def handle_keypad_led_change(self, code, data):
"""Event 510-511, detail the led state and led flash state respectively."""
parse = re.match('^[0-9A-F]{2}$', data)
flash = 'ON'
if (code == '511'):
flash = 'FLASH'
if parse:
mask = int(data,16)
for LED in evl_LedMask:
if (mask & evl_LedMask[LED]):
Domoticz.Log("Keypad LED "+flash+": "+LED)
return 1
else:
Domoticz.Error("Invalid data ("+data+") has been passed for code: '"+code+"'.")
def handle_keypad_update(self, code, data):
"""Handle general- non partition based info"""
for part in self.alarmState['partition']:
self.alarmState['partition'][part]['status'].update(evl_ResponseTypes[code]['status'])
Domoticz.Debug(str.format("[All partitions] state has updated: {0}", json.dumps(evl_ResponseTypes[code]['status'])))
def handle_verbose_status(self, code, data):
"""Event 849, This command is issued when a trouble appears on the system and roughly every 5 minutes until the trouble is cleared.."""
parse = re.match('^[0-9]{2}$', data)
if parse:
mask = int(data,16)
for trouble in evl_TroubleMask:
if (mask & evl_TroubleMask[trouble]):
Domoticz.Log("Verbose Trouble Status: "+trouble)
return 1
else:
Domoticz.Error("Invalid data ("+data+") has been passed for code: '"+code+"'.")
def handle_poll_response(self, code, data):
"""Handle command responses"""
Domoticz.Debug("'"+evl_ResponseTypes[code]['name']+"' command acknowledged.")
def handle_time_response(self, code, data):
"""Handle time responses, e.g. '2128042318'"""
parse = re.match('^[0-9]{10}$', data)
if parse:
try:
theTime = datetime.now()
theTime.replace(hour=int(data[:2]),minute=int(data[2:4]),month=int(data[4:6]),day=int(data[6:8]),year=2000+int(data[8:]))
message = '{:02}:{:02} {:02}/{:02}/{:04}'.format(theTime.hour, theTime.minute, theTime.day, theTime.month, theTime.year)
Domoticz.Log("Received time synchronization ('"+message+"')")
except ValueError:
Domoticz.Error(str.format("Error processing time synchronization: '{0}'. Skipping.", data))
else:
Domoticz.Error("Invalid time data ("+data+") has been passed for code: '"+code+"'.")
def handle_output_pressed(self, code, data):
"""Command Output Pressed, code: '912', Data: <partition><output> e.g '11'"""
part = data[:1]
output = data[-1:]
deviceNo = OUTPUT_BASE+int(data)
if (not deviceNo in Devices):
Domoticz.Device(Name="Partition "+part+" Output "+output, Unit=deviceNo, Type=17, Subtype=0, Switchtype=9).Create()
Domoticz.Log("Created Command Output device for Partition "+part+" Output "+output)
UpdateDevice(deviceNo, 1, "On", False)
Domoticz.Log("Command output pressed for Partition "+part+" Output "+output)
def handle_system_response_error(self, code, data):
"""Handle system error responses"""
try:
Domoticz.Error(str.format("System Error: '{0}' with data: {1}", evl_ResponseTypes[code]['name'], data))
Domoticz.Error(str.format("---> Details: '{0}'", evl_Errors[data]['description'] ))
except:
Domoticz.Error("Response error not handled: '"+code+"' command, data: "+data)
def handle_command_response_error(self, code, data):
"""Handle command error responses"""
try:
Domoticz.Error(str.format("System Error: '{0}' with data: {1}", evl_ResponseTypes[code]['name'], data))
except:
Domoticz.Error("Response error not handled: '"+code+"' command, data: "+data)
def handle_message_response_error(self, code, data):
"""Handle command message responses"""
try:
Domoticz.Log(str.format("Message {0}: '{1}' with data: {2}", code, evl_ResponseTypes[code]['name'], data))
except:
Domoticz.Error("Response message not handled: '"+code+"' command, data: "+data)
def handle_login(self, command, data):
if (data == "0"):
Domoticz.Error("Login Unsuccessful.")
elif (data == "1"):
Domoticz.Log("Login Successful.")
self.alarmConn.Send(CreateChecksum(evl_Commands['StatusReport']))
self.alarmConn.Send(CreateChecksum(evl_Commands['TimeBroadcast']), 3)
self.alarmConn.Send(CreateChecksum(evl_Commands['PartitionKeypress']+'1*1#'), 5)
self.alarmConn.Send(CreateChecksum(evl_Commands['DumpZoneTimers']), 8)
elif (data == "3"):
message = evl_Commands['Login']+Parameters["Password"]
message = CreateChecksum(message)
Domoticz.Debug("Sending Login Response.")
self.alarmConn.Send(message)
def notHandled(self, command, data):
Domoticz.Error("EnvisaLink returned unhandled message: '"+command+"', ignored. Data: '"+data+"'")
def SyncDevices(self, TimedOut):
# Make sure that the Domoticz devices are in sync (by definition, the device is connected)
if (1 in Devices):
UpdateDevice(1, self.playerState, self.mediaDescrption, TimedOut)
if (2 in Devices):
if (Devices[2].nValue != self.mediaLevel) or (Devices[2].TimedOut != TimedOut):
UpdateDevice(2, self.mediaLevel, str(self.mediaLevel), TimedOut)
if (4 in Devices):
if (self.playerState == 4) or (self.playerState == 5):
UpdateDevice(4, 2, str(self.percentComplete), TimedOut)
else:
UpdateDevice(4, 0, str(self.percentComplete), TimedOut)
return
def ValidChecksum(message):
checkSum = 0
for c in message[:-2]:
checkSum = checkSum + ord(c)
checkSum = 255 & checkSum
origChecksum = int(message[-2:],16)
if (checkSum == origChecksum):
return True
return False
def CreateChecksum(message):
checkSum = 0
for c in message:
checkSum = checkSum + ord(c)
return message+('%02X'% checkSum)[-2:]+"\r\n"
global _plugin
_plugin = BasePlugin()
def onStart():
global _plugin
_plugin.onStart()
def onStop():
global _plugin
_plugin.onStop()
def onConnect(Connection, Status, Description):
global _plugin
_plugin.onConnect(Connection, Status, Description)
def onMessage(Connection, Data):
global _plugin
_plugin.onMessage(Connection, Data)
def onSecurityEvent(Unit, Level, Description):
global _plugin
_plugin.onSecurityEvent(Unit, Level, Description)
def onCommand(Unit, Command, Level, Hue):
global _plugin
_plugin.onCommand(Unit, Command, Level, Hue)
def onNotification(Name, Subject, Text, Status, Priority, Sound, ImageFile):
global _plugin
_plugin.onNotification(Name, Subject, Text, Status, Priority, Sound, ImageFile)
def onDisconnect(Connection):
global _plugin
_plugin.onDisconnect(Connection)
def onHeartbeat():
global _plugin
_plugin.onHeartbeat()
# Generic helper functions
def DumpConfigToLog():
for x in Parameters:
if Parameters[x] != "":
Domoticz.Debug( "'" + x + "':'" + str(Parameters[x]) + "'")
Domoticz.Debug("Settings count: " + str(len(Settings)))
for x in Settings:
Domoticz.Debug( "'" + x + "':'" + str(Settings[x]) + "'")
Domoticz.Debug("Image count: " + str(len(Images)))
for x in Images:
Domoticz.Debug( "'" + x + "':'" + str(Images[x]) + "'")
Domoticz.Debug("Device count: " + str(len(Devices)))
for x in Devices:
Domoticz.Debug("Device: " + str(x) + " - " + str(Devices[x]))
Domoticz.Debug("Device ID: '" + str(Devices[x].ID) + "'")
Domoticz.Debug("Device Name: '" + Devices[x].Name + "'")
Domoticz.Debug("Device nValue: " + str(Devices[x].nValue))
Domoticz.Debug("Device sValue: '" + Devices[x].sValue + "'")
Domoticz.Debug("Device LastLevel: " + str(Devices[x].LastLevel))
Domoticz.Debug("Device Image: " + str(Devices[x].Image))
return
def UpdateDevice(Unit, nValue, sValue, TimedOut):
# Make sure that the Domoticz device still exists (they can be deleted) before updating it
if (Unit in Devices):
if (Devices[Unit].nValue != nValue) or (Devices[Unit].sValue != sValue) or (Devices[Unit].TimedOut != TimedOut):
Devices[Unit].Update(nValue=nValue, sValue=str(sValue), TimedOut=TimedOut)
Domoticz.Debug("Update "+str(nValue)+":'"+str(sValue)+"' ("+Devices[Unit].Name+")")
return