forked from sfeakes/AqualinkD
-
Notifications
You must be signed in to change notification settings - Fork 0
/
serialadapter.h
108 lines (92 loc) · 3.61 KB
/
serialadapter.h
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
#ifndef SERIALADAPTER_H_
#define SERIALADAPTER_H_
bool push_rssa_cmd(unsigned char *cmd);
unsigned char *get_rssa_cmd(unsigned char source_message_type);
void remove_rssa_cmd();
bool process_rssadapter_packet(unsigned char *packet, int length, struct aqualinkdata *aq_data);
//void rssadapter_device_on(unsigned char devID);
//void rssadapter_device_off(unsigned char devID);
void set_aqualink_rssadapter_aux_state(int buttonIndex, bool turnOn);
void get_aqualink_rssadapter_setpoints();
void set_aqualink_rssadapter_pool_setpoint(char *args, struct aqualinkdata *aqdata);
void set_aqualink_rssadapter_spa_setpoint(char *args, struct aqualinkdata *aqdata);
void increase_aqualink_rssadapter_pool_setpoint(char *args, struct aqualinkdata *aqdata);
void increase_aqualink_rssadapter_spa_setpoint(char *args, struct aqualinkdata *aqdata);
/*
CAN ONLY REPLY WITH BELOW TO STATUS MESSAGE, UNLESS FOLLOWON 0x07
Message is reply ACK as below
--------- Send ACK -----------
0x10|0x02|0x00|0x01|DeviceID|What|0xXX|0x10|0x03|
DeviceID = Below
What = 0x05 Query Value | 0x35 Set Value on next command.
--------- Reply Msg -------------
0x10|0x02|0x48|ReplyType|DeviceID|????|Value|0x00|0xXX|0x10|0x03|
ReplyType 0x13=status, 0x07=set value next message
DeviceID
???? Not sure 0x00 modst of the time, 0x02 for (not set or vbat return)
Value What it's set to, except VBAT. or 0x07 set on next command
--------- Send reply to above if 0x07 ---------
0x10|0x02|0x00|0x01|0x00|Value|0x4f|0x10|0x03|
Value to be set
--------- Send received from above ---------
0x10|0x02|0x48|ReplyType|DeviceID|????|Value|0x00|0xXX|0x10|0x03|
Same as previous reply.
*/
#define RS_SA_DEVSTATUS 0x13
// Setpoints changes are in this group./
#define RS_SA_MODEL 0x00
#define RS_SA_OPTIONS 0x01
#define RS_SA_POOLSP 0x05
#define RS_SA_POOLSP2 0x06
#define RS_SA_SPASP 0x07
#define RS_SA_POOLTMP 0x08
#define RS_SA_AIRTMP 0x09
#define RS_SA_UNITS 0x0a
#define RS_SA_SPATMP 0x0b
#define RS_SA_SOLTMP 0x0c
#define RS_SA_OPMODE 0x0d
#define RS_SA_VBAT 0x0e
#define RS_SA_WFALL 0x0f
/*
// Set & Query options
Query or Change simple on/off
--------- Send ACK --------------
0x10|0x02|0x00|0x01|What|DeviceID|0xXX|0x10|0x03|
What - Byte 4 = What (0x00 Query | 0x81 On | 0x80 off )
DeviceID - Byte 5 = (ID's below)
--------- Reply Msg -------------
In return
0x10|0x02|0x48|0x13 |0x02 |0x00 |0x0d|0x10|0x8c|0x10|0x03|
0x10|0x02|0x48|MsgType|Status1|Status2|0x0e|DeviceID|0xXX|0x10|0x03|
MsgType - Byte 3 = 0x13 (some state message)??
StatType - Byte 4 = 0x02 or 0x03 (not sure meaning) Status Type ????
Status1 - Byte 5 = 0x00 0x01 (???) if Byte4 is 0x02 then this is state 0x00=off 0x01=on /
Status2 - Byte 6 = 0x00 0x01 0x0e(option switch set can't change???) if byte4 is 0x03, this this looks to be state
DeviceID - Byte 7 = Should match request.
*/
// These are duplicate for some above, so be careful
#define RS_SA_PUMP 0x0c
#define RS_SA_PUMPLO 0x0d
#define RS_SA_SPA 0x0e
// Unique again
#define RS_SA_CLEANR 0x10
#define RS_SA_POOLHT 0x11
#define RS_SA_POOLHT2 0x12
#define RS_SA_SOLHT 0x14
#define RS_SA_SPAHT 0x13
#define RS_SA_AUX1 0x15
#define RS_SA_AUX2 0x16
#define RS_SA_AUX3 0x17
#define RS_SA_AUX4 0x18
#define RS_SA_AUX5 0x19
#define RS_SA_AUX6 0x1a
#define RS_SA_AUX7 0x1b
#define RS_SA_AUX8 0x1c
#define RS_SA_AUX9 0x1d
#define RS_SA_AUX10 0x1e
#define RS_SA_AUX11 0x1f
#define RS_SA_AUX12 0x20
#define RS_SA_AUX13 0x21
#define RS_SA_AUX14 0x22
#define RS_SA_AUX15 0x23
#endif // SERIALADAPTER_H_