A template used for installing areaDetector IOCs with NSLS2 prebuilt bundles.
Component | Description |
---|---|
startupScripts | Directory containing IOC st.cmd startup scripts for each device configured for use with the IOC template |
dependencyScripts | Some devices need additional scripts run pre-iocInit (ex. Andor3 detector). They are housed here |
unique.cmd | File containting all IOC specific environement variables |
envPaths | File contatining relative paths to all EPICS components. DO NOT EDIT, all components relative to unique.cmd |
config | Basic config file for use with procServer and soft-ioc |
logs | directory contatining IOC startup issues and log dumps |
.hgignore | ignore file for use with mercurial version control |
cleanup.sh | script used to remove all unused portions of ioc-template once it is deployed |
The recommended usage for this repository is with initIOC. initIOC
is a configurable script that will auto-initialize any number of detector IOCs that are supported by ioc-template
.
For initIOC
usage instructions, please check the above linked repositry.
To use the ioc-template, start by cloning this repository, or downloading a release.
Then perform the following steps in order:
- Remove the st.cmd file and copy one from the
startupScripts
directory that is appropriate for the IOC in use. - Check to make sure that the startup script is pointing to the correct binary location. This will be in the first line of the startup script.
- Edit the
unique.cmd
file, editing all relevant environment variables to match with your IOC. Note that CAM-CONNECT is the variable used to connect to the camera, and can be a serial number, IP etc. - If using mercurial, initialize the hg repository, add, commit, and push the contents to a remote
- Start the IOC by running
./st.cmd
, or if required, first run the dependency script.