Programming registers for packmonitor controller

These registers are identified by a single command byte and zero or more data bytes

0x00 to 0x20

  • (reserved)

0x21 Set high-current limit (unsigned int)

  • Set in milliamps, range 0 to 65535
  • Default is 10000 (10a)

0x22 Set high-temp limit (unsigned int)

  • Set in millidegrees C, range 0 to 65535 or 65.535c
  • Default 45000 or 45c
  • Send data as char string

0x23 Set low-temp limit (int / signed 16-bit)

  • Set in millidegrees C, range -32768 to 32767 or -32.768c to 32.767c
  • Default 0c
  • Send data as char string

0x24 Set pack high-voltage limit in millivolts (unsigned int)

  • valid range 9600 to 26000, values outside this range will be ignored
  • default 14800
  • Send data as char string

0x25 Set pack low-voltage limit in millivolts (unsigned int)

  • valid range 600 to 26000, values outside this range will be ignored
  • default 10800 or 10.8 volts
  • Send data as char string

0x26 Set config0 bits (byte) (0 disabled, 1 enabled)

  • Bit 7: Disable all protection (default 0)
    • 1: Monitor pack only, ignore all fault conditions
    • 0: Monitor fault conditions as configured (default)
  • Bit 6: Over-current protection
    • 1: Disconnect pack when current draw exceeds set-point (default)
    • 0: Disable over-current protection
  • Bit 5: Over-temperature protection
    • 1: Disconnect pack when temperature above set-point (default)
    • 0: Ignore low temperature condition
  • Bit 4: Under-temperature protection
    • 1: Disconnect pack when temperature below set-point
    • 0: Ignore low temperature condition (default)
  • Bit 3: Under-voltage protection
    • 1: Disconnect pack when voltage below set point (default)
    • 0: Ignore under-voltage condition
  • Bit 2: Over-voltage protection
    • 1: Disconnect pack when voltage exceeds set point
    • 0: Ignore over-voltage conditions (default)
  • Bit 1: (reserved)
  • Bit 0: Enable status leds
    • 1: Status LEDs work with button (default)
    • 0: Status LEDs disabled

0x27 Set config1 bits (byte)

  • Bit 0 to 7: (reserved)

0x28 Set config2 bits (byte)

  • Bit 0 to 7: (reserved)

0x29 Read config0 (byte)

  • See set config0 for details

0x2A Read config1 (byte)

  • See set config1 for details

0x2B Read config2 (byte)

  • See set config2 for details

0x2C Read status0 bites

  • Bit 7: Config set
  • Bit 6: Time set
  • Bit 5: Temperature warning (within 3 deg of limits)
  • Bit 4: Current warning (within 1 amps of limit)
  • Bit 3: Voltage warning (within 250mV of limits)
  • Bit 2: T-sense out of range
  • Bit 1: I-sense out of range
  • Bit 0: V-sense out of range

0x2D Read status1 bits

0x2E through 0x2F

  • (reserved)

0x30 Clear coulomb counter, no data

  • Reset coulomb counter

0x31 Read coulomb counter. returns float as char* array

  • Shows surplus amps in, or deficit amps out

0x32 Clear total amps counter, except lifetime, returns float as char* array

0x33 Read load amperage, returns float as char* array

  • Current load in amps

0x34 Read total pack amps in, returns float as char* array

0x35 Read total pack amps out, returns float as char* array

0x36 Read lifetime amps in, returns float as char* array

0x37 Read lifetime amps out, returns float as char* array

0x38 Clear voltage memory, no data

0x39 Read pack voltage, returns float as char* array

  • Returns the current pack voltage in volts

0x3A Read lowest voltage memory, returns float as char* array

  • Lowest voltage seen since last clear in volts

0x3B Read lowest voltage timestamp, unsigned long

  • Timestamp for when the lowest voltage was recorded

0x3C Read highest voltage memory, returns float as char* array

  • Highest voltage seen since last clear in volts

0x3D Read highest voltage timestamp, unsigned long

  • Timestamp for when the highest voltage was recorded

0x3E Read bus voltage, returns float as char* array

  • Returns the current bus voltage in volts

0x3F

  • (reserved)

0x40 Clear temperature memories, no data

0x41 Read T0 thermistor, returns float as char* array

0x42 Read T0 lowest, returns float as char* array

0x43 Read T0 highest, returns float as char* array

0x44 Read T1 thermistor, returns float as char* array

0x45 Read T1 lowest, returns float as char* array

0x46 Read T1 highest, returns float as char* array

0x47 T0 lowest memory timestamp, unsigned long

0x48 T1 lowest memory timestamp, unsigned long

0x49 T0 highest memory timestamp, unsigned long

0x4A T1 highest memory timestamp, unsigned long

0x4B through 0x4F

  • (reserved)

0x50 Clear disconnect history

0x51 Read total over-current disconnects (usigned int)

0x52 Read total under-voltage disconnects (usigned int)

0x53 Read total over-voltage disconnects (usigned int)

0x54 Read total under-temp disconnects (usigned int)

0x55 Read total over-temp disconnects (usigned int)

0x56 Read last disconnect timestamp (ulong)

0x57 Read last disconnect reason code (byte)

0x58 through 0x5F

  • (reserved)

0x60 Set time (char *)

  • Tranfer time from master to slave
  • Expects unix timestamp sent as char string

0x61 Read first-initialized timestamp ulong

0x62 Read current timestamp ulong

0x63 Read time since last sync ulong

0x64 Read uptime ulong

0x65 through 0xFF