Testing Vita with snabb loadtest #41

Open
eugeneia opened this issue Jun 21, 2018 · 0 comments
Open

Testing Vita with snabb loadtest #41

eugeneia opened this issue Jun 21, 2018 · 0 comments

Comments

@eugeneia
Copy link
Member

eugeneia commented Jun 21, 2018

Copied into an issue from src/program/vita/vita-loadtest.md to allow for comments.

Say you have some test hardware and want to evaluate how Vita runs on it. This issue will walk you through how I test Vita on a low-budget testing box using snabb loadtest. The test setup will look like this:

vita-loadtest

My low-budget testing box has an AMD Ryzen 5 1600 CPU (6 cores, 12 threads) and two 4‑port Intel i350 1 GbE NICs. Our test setup will use six out of the total eight 1 GbE ports and run two Vita nodes simultaneously, so having many hardware threads and Ethernet interfaces does not hurt. The interfaces are wired like this (you can get the PCI bus address of an interface via lspci):

22:00.0 ←→ 23:00.0
22:00.1 ←→ 23:00.1
22:00.2 ←→ 23:00.2

Note: Snabb needs Linux to be booted with iommu=off for its device drivers to function. Additionally, I have turned off AMD Turbo Core in BIOS to get dependable CPU frequency. Intel calls the equivalent feature Turbo Boost.

So lets get started by cloning Vita, building a test build, and switching to the src/ directory:

$ git clone https://github.com/inters/vita
$ cd vita
$ make -j # builds a test build by default
$ cd src

We can start by running the the software-based, single-core benchmark test to get a baseline of what we can expect from this machine:

$ sudo program/vita/test.snabb IMIX 10e6 1 2
                               ^    ^    ^ ^
                               |    |    | \- CPU core to use
                               |    |    \- # of routes to test with
                               |    \- # of packets
                               \- packet size

That will print a bunch of output and then something like:

May 03 2019 23:03:47 SoftBench: Processed 10.0 million packets in 5.65 seconds
May 03 2019 23:03:47 SoftBench: 1.768 Mpps
May 03 2019 23:03:47 SoftBench: 3543404200 Bytes
May 03 2019 23:03:47 SoftBench: 5.140 Gbps (on GbE)

And once more for 60 byte packets:

$ sudo program/vita/test.snabb 60 10e6 1 2
...
May 03 2019 23:06:00 SoftBench: Processed 10.0 million packets in 3.54 seconds
May 03 2019 23:06:00 SoftBench: 2.825 Mpps
May 03 2019 23:06:00 SoftBench: 600012000 Bytes
May 03 2019 23:06:00 SoftBench: 1.559 Gbps (on GbE)

The results suggest that our setup should be able to handle 1 GbE line-rate at any packet size using only a single CPU core. So let’s confirm that with an end-to-end test using snabb loadtest find-limit.

First of all, we start two Vita nodes, and assign them the names node1 and node2 respectively (these names are later used as handles for snabb config):

$ sudo ./vita --name node1 --cpu 1,2,3,4,5 &> node1.log &
$ sudo ./vita --name node2 --cpu 6,7,8,9,10 &> node2.log &

loadtest takes Pcap records, replays the contained packets in a loop on its interfaces, and checks if the number of packets received match the number of packets it sent. So we need to configure our Vita nodes to form such a loop and generate Pcap records to use as test traffic accordingly. This is the configuration node1.conf for the first Vita node with a single route (do not start copying it yet, you will not have to write these by hand for testing purposes):

private-interface4 {
  pci 23:00.0;
  ip 172.16.0.10;
  nexthop-ip 172.16.0.1;
  nexthop-mac 02:00:00:00:00:00;
}
public-interface4 {
  pci 22:00.1;
  ip 172.16.0.10;
  nexthop-ip 172.17.0.10;
}
route4 {
  id test1;
  net "172.17.1.0/24";
  gateway { ip 172.17.0.10; }
  spi 1001;
  preshared-key 0000000000000000000000000000000000000000000000000000000000000001;
}

Most of it should be fairly self explanatory: we assign the desired ports via their PCI bus addresses, and set the interface’s own addresses as well as the addresses of the next hops. In this case, the private and public interface addresses are the same, but they need not be. The next hop of the private interface (this would normally be your local router) will be snabb loadtest. Since loadtest does not speak ARP, we configure a fixed MAC destination address for this next hop. This will prevent Vita from attempting to look up the next hop’s MAC addresses via ARP, and instead use the preconfigured address. The next hop of the public interface (this would normally be your gateway to the Internet) is configured to be the other Vita node in the test setup. Finally, we define a single route to the subnet 172.17.1.0/24 via the second Vita node with a dummy key. For the other Vita node, node2.conf is symmetric:

private-interface4 {
  pci 22:00.2;
  ip 172.17.0.10;
  nexthop-ip 172.17.0.1;
  nexthop-mac 02:00:00:00:00:00;
}
public-interface4 {
  pci 23:00.1;
  ip 172.17.0.10;
  nexthop-ip 172.16.0.10;
}
route4 {
  id test1;
  net "172.16.1.0/24";
  gateway { ip 172.16.0.10; }
  spi 1001;
  preshared-key 0000000000000000000000000000000000000000000000000000000000000001;
}

Because typing out configuration files for testing gets old fast, and we still need matching Pcap records, Vita comes with a utility that generates both of these from a meta-configuration file. For the first node we have gentest-node1.conf:

private-interface4 {
  pci 23:00.0;
  ip 172.16.0.10;
  nexthop-ip 172.16.0.1;
  nexthop-mac 02:00:00:00:00:00;
}
public-interface4 {
  pci 22:00.1;
  ip 172.16.0.10;
  nexthop-ip 172.17.0.10;
}
route-prefix "172.17";
nroutes 1;
packet-size 60;

…and for the second node gentest-node2.conf:

private-interface4 {
  pci 22:00.2;
  ip 172.17.0.10;
  nexthop-ip 172.17.0.1;
  nexthop-mac 02:00:00:00:00:00;
}
public-interface4 {
  pci 23:00.1;
  ip 172.17.0.10;
  nexthop-ip 172.16.0.10;
}
route-prefix "172.16";
nroutes 1;
packet-size 60;

These meta-configurations allows us to define the number of routes to use in the test case, as well the packet size of the packets in the generated Pcap records. We can then generate equivalent configurations to the above using genconf.snabb and, more importantly, Pcap records with adequate test traffic using genpcap.snabb:

$ sudo program/vita/genconf.snabb < gentest-node1.conf \
   | sudo ./snabb config set node1 /
$ sudo program/vita/genpcap.snabb < gentest-node1.conf \
   > node1-private-in.pcap
$ sudo program/vita/genconf.snabb < gentest-node2.conf \
   | sudo ./snabb config set node2 /
$ sudo program/vita/genpcap.snabb < gentest-node2.conf \
   > node2-private-in.pcap

And now we can run find-limit, which will determine the No-Drop-Rate (NDR) by means of a binary search:

$ sudo ./snabb loadtest find-limit -b 1e9 --cpu 11 \
    node1-private-in.pcap node1 node2 22:00.0 \
    node2-private-in.pcap node2 node1 23:00.2

The -b flag tells it that the maximum rate is 1 GbE as limited by the NIC, and the two “streams” are configured so that packets from node1-private-in.pcap will be sent via the private port of node #1 (wired to 22:00.0) and matched against the egress traffic of node #2 (wired to 23:00.2), and vice versa. find-limit will print a bunch of output and finally announce the effective NDR it has determined, in my case (partially redacted):

Applying 0.500000 Gbps of load.
  node1:
    TX 744128 packets (0.744128 MPPS), 44647680 bytes (0.500054 Gbps)
    RX 746467 packets (0.746467 MPPS), 44788020 bytes (0.501626 Gbps)
    Loss: 0 ingress drop + -2339 packets lost (-0.314328%)
  node2:
    TX 744128 packets (0.744128 MPPS), 44647680 bytes (0.500054 Gbps)
    RX 746439 packets (0.746439 MPPS), 44786340 bytes (0.501607 Gbps)
    Loss: 0 ingress drop + -2311 packets lost (-0.310565%)
...
Applying 0.625000 Gbps of load.
  node1:
    TX 930058 packets (0.930058 MPPS), 55803480 bytes (0.624999 Gbps)
    RX 907731 packets (0.907731 MPPS), 54463860 bytes (0.609995 Gbps)
    Loss: 0 ingress drop + 22327 packets lost (2.400603%)
  node2:
    TX 930058 packets (0.930058 MPPS), 55803480 bytes (0.624999 Gbps)
    RX 907701 packets (0.907701 MPPS), 54462060 bytes (0.609975 Gbps)
    Loss: 0 ingress drop + 22357 packets lost (2.403829%)
Failed.
...
Applying 0.609000 Gbps of load.
  node1:
    TX 906253 packets (0.906253 MPPS), 54375180 bytes (0.609002 Gbps)
    RX 907728 packets (0.907728 MPPS), 54463680 bytes (0.609993 Gbps)
    Loss: 0 ingress drop + -1475 packets lost (-0.162758%)
  node2:
    TX 906253 packets (0.906253 MPPS), 54375180 bytes (0.609002 Gbps)
    RX 907623 packets (0.907623 MPPS), 54457380 bytes (0.609923 Gbps)
    Loss: 0 ingress drop + -1370 packets lost (-0.151172%)
Success.
0.609

Huh, 0.609 Gbps. How come? This figure is explained if you consider the IPsec ESP overhead added to the packets while in transit between Vita nodes. In tunnel mode, the overhead for 60 byte packets will be 54 bytes (encapsulating IP header + ESP protocol header overhead + zero bytes of padding to four byte boundary), so the effective packet size between the public interfaces is 114 bytes. If we add the 24 bytes of Ethernet overhead (7 bytes preamble + 1 byte start-of-frame + 4 bytes CRC + 12 bytes interframe gap) and calculate the ratio we get (84 / 138) * 100 = ~60.869%. This adds up.

You can test with different configurations (try packet-size IMIX, or nroutes 40) by editing gentest-node?.conf and rerunning the genconf.snabb/genpcap.snabb commands from above. Vita nodes can be reconfigured via snabb config while they are running. With increasing packet sizes the packet overhead in transit will be less visible.

There is also snabb loadtest transient which can simulate basic traffic patterns like ramp_up_down:

$ sudo ./snabb loadtest transient -b 1e9 --cpu 11 \
    node1-private-in.pcap node1 node2 22:00.0 \
    node2-private-in.pcap node2 node1 23:00.2

Using more CPU cores

You can test using more CPU cores by adding more public interfaces to the configuration. Vita should scale linearly with added CPU cores, but do note that a Vita instance will use the CPU threads supplied to it via the --cpu argument, and that these might be HyperThreads that share a single physical core in which case performance does not increase linearly. For instance, a gentest-node1.conf using two cores could look like this:

private-interface4 {
  pci 23:00.0;
  ip 172.16.0.10;
  nexthop-ip 172.16.0.1;
  nexthop-mac 02:00:00:00:00:00;
}
public-interface4 {
  pci 22:00.1;
  ip 172.16.0.10;
  nexthop-ip 172.17.0.10;
}
public-interface4 {
  pci 22:00.1;
  ip 172.16.0.11;
  nexthop-ip 172.17.0.11;
  queue 2;
}
route-prefix "172.17";
nroutes 4;
packet-size IMIX;

The corresponding gentest-node2.conf would look like this:

private-interface4 {
  pci 22:00.2;
  ip 172.17.0.10;
  nexthop-ip 172.17.0.1;
  nexthop-mac 02:00:00:00:00:00;
}
public-interface4 {
  pci 23:00.1;
  ip 172.17.0.10;
  nexthop-ip 172.16.0.10;
  queue 1;
}
public-interface4 {
  pci 23:00.1;
  ip 172.17.0.11;
  nexthop-ip 172.16.0.11;
  queue 2;
}
route-prefix "172.16";
nroutes 4;
packet-size IMIX;
@eugeneia eugeneia changed the title Testing Vita with snabb loadtest Testing Vita with snabb loadtest Jun 21, 2018