All datasets used in the paper are here. They are

Magnetic axial flux sets:

Current sets:

Accelerometer (Vibration) sets:

The naming convetion follows the rule:

  • v000: version of the database (concerns only to author).
  • SCIG: electrical machine is a Squirrel-Cage Induction Generator (SCIG).
  • SC: The inserted fault is short-circuit (SC)
  • SENSORC: The sensor used to monitor the machine.
  • FOURIER: The feature extracted method used to build the dataset.

The experimental setting is based on Reboucas et al, 2018 diagram's. More detais are exhibited in this paper.

Bench. Diagram.

The features in Fourier, HOS and SCM might vary, however the common fields in theses sets are:

Current sensor (SENSORC)

The common features in files v000_SCIG_SC_SENSORC_FOURIER.csv, v000_SCIG_SC_SENSORC_HOS.csv and v000_SCIG_SC_SENSORC_SCM.csv are

Field Description
idx The sample index in dataframe
Freq_Rated Frequency applied into Driven Machine's frequency converter (FC-1)
Freq_Gen Frequency applied into Generator's frequency converter (FC-2)
CC_bus Voltage of dc-bus
Power Measures three-phase power
I_R_rms Line Current RMS value
I_S_rms Line Current RMS value
I_T_rms Line Current RMS value
Load Percentage of electrical load in cc-bus
Class Operational condition

The unique features in v000_SCIG_SC_SENSORC_FOURIER.csv are:

Field Description
FOURIER ==================
fx1_R The fundamental frequency of line current R
fx0d5_R The 0.5th multiple of the fundamental frequency of line current R
fx1d5_R The 1.5th multiple of the fundamental frequency of line current R
fx2d5_R The 2.5th multiple of the fundamental frequency of line current R
fx3_R The 3rd multiple of the fundamental frequency of line current R
fx5_R The 5th multiple of the fundamental frequency of line current R
fx7_R The 7th multiple of the fundamental frequency of line current R
fx1_S The fundamental frequency of line current R
fx0d5_S The 0.5th multiple of the fundamental frequency of line current S
fx1d5_S The 1.5th multiple of the fundamental frequency of line current S
fx2d5_S The 2.5th multiple of the fundamental frequency of line current S
fx3_S The 3rd multiple of the fundamental frequency of line current S
fx5_S The 5th multiple of the fundamental frequency of line current S
fx7_S The 7th multiple of the fundamental frequency of line current S
fx1_T The fundamental frequency of line current R
fx0d5_T The 0.5th multiple of the fundamental frequency of line current T
fx1d5_T The 1.5th multiple of the fundamental frequency of line current T
fx2d5_T The 2.5th multiple of the fundamental frequency of line current T
fx3_T The 3rd multiple of the fundamental frequency of line current T
fx5_T The 5th multiple of the fundamental frequency of line current T
fx7_T The 7th multiple of the fundamental frequency of line current T

The unique features in v000_SCIG_SC_SENSORC_HOS.csv are:

Field Description
Skewness_R The Skewness value of of line current R
Kurtosis_R The Kurtosis value of of line current R
Variance_R The Variance value of of line current R
RMS_R The RMS value of of line current R
Skewness_S The Skewness value of of line current S
Kurtosis_S The Kurtosis value of of line current S
Variance_S The Variance value of of line current S
RMS_S The RMS value of of line current S
Skewness_T The Skewness value of of line current T
Kurtosis_T The Kurtosis value of of line current T
Variance_T The Variance value of of line current T
RMS_T The RMS value of of line current T

The unique features in v000_SCIG_SC_SENSORC_SCM.csv are:

Field Description
scm_COR_R The Skewness value of of line current R
scm_IDM_R The Kurtosis value of of line current R
scm_ENT_R The Variance value of of line current R
scm_CSD_R The RMS value of of line current R
scm_CSR_R The Skewness value of of line current S
scm_DKL_R The Kurtosis value of of line current S
scm_MDR_R The Variance value of of line current S
scm_CAD_R The RMS value of of line current S