All datasets used in the paper are here. They are
Magnetic axial flux sets:
Current sets:
Accelerometer (Vibration) sets:
The naming convetion follows the rule:
v000
: version of the database (concerns only to author).SCIG
: electrical machine is a Squirrel-Cage Induction Generator (SCIG).SC
: The inserted fault is short-circuit (SC)SENSORC
: The sensor used to monitor the machine.FOURIER
: The feature extracted method used to build the dataset.
The experimental setting is based on Reboucas et al, 2018 diagram's. More detais are exhibited in this paper.
The features in Fourier, HOS and SCM might vary, however the common fields in theses sets are:
The common features in files v000_SCIG_SC_SENSORC_FOURIER.csv
, v000_SCIG_SC_SENSORC_HOS.csv
and v000_SCIG_SC_SENSORC_SCM.csv
are
Field | Description |
---|---|
idx | The sample index in dataframe |
Freq_Rated | Frequency applied into Driven Machine's frequency converter (FC-1) |
Freq_Gen | Frequency applied into Generator's frequency converter (FC-2) |
CC_bus | Voltage of dc-bus |
Power | Measures three-phase power |
I_R_rms | Line Current RMS value |
I_S_rms | Line Current RMS value |
I_T_rms | Line Current RMS value |
Load | Percentage of electrical load in cc-bus |
Class | Operational condition |
The unique features in v000_SCIG_SC_SENSORC_FOURIER.csv
are:
Field | Description |
---|---|
FOURIER | ================== |
fx1_R | The fundamental frequency of line current R |
fx0d5_R | The 0.5th multiple of the fundamental frequency of line current R |
fx1d5_R | The 1.5th multiple of the fundamental frequency of line current R |
fx2d5_R | The 2.5th multiple of the fundamental frequency of line current R |
fx3_R | The 3rd multiple of the fundamental frequency of line current R |
fx5_R | The 5th multiple of the fundamental frequency of line current R |
fx7_R | The 7th multiple of the fundamental frequency of line current R |
fx1_S | The fundamental frequency of line current R |
fx0d5_S | The 0.5th multiple of the fundamental frequency of line current S |
fx1d5_S | The 1.5th multiple of the fundamental frequency of line current S |
fx2d5_S | The 2.5th multiple of the fundamental frequency of line current S |
fx3_S | The 3rd multiple of the fundamental frequency of line current S |
fx5_S | The 5th multiple of the fundamental frequency of line current S |
fx7_S | The 7th multiple of the fundamental frequency of line current S |
fx1_T | The fundamental frequency of line current R |
fx0d5_T | The 0.5th multiple of the fundamental frequency of line current T |
fx1d5_T | The 1.5th multiple of the fundamental frequency of line current T |
fx2d5_T | The 2.5th multiple of the fundamental frequency of line current T |
fx3_T | The 3rd multiple of the fundamental frequency of line current T |
fx5_T | The 5th multiple of the fundamental frequency of line current T |
fx7_T | The 7th multiple of the fundamental frequency of line current T |
The unique features in v000_SCIG_SC_SENSORC_HOS.csv
are:
Field | Description |
---|---|
Skewness_R | The Skewness value of of line current R |
Kurtosis_R | The Kurtosis value of of line current R |
Variance_R | The Variance value of of line current R |
RMS_R | The RMS value of of line current R |
Skewness_S | The Skewness value of of line current S |
Kurtosis_S | The Kurtosis value of of line current S |
Variance_S | The Variance value of of line current S |
RMS_S | The RMS value of of line current S |
Skewness_T | The Skewness value of of line current T |
Kurtosis_T | The Kurtosis value of of line current T |
Variance_T | The Variance value of of line current T |
RMS_T | The RMS value of of line current T |
The unique features in v000_SCIG_SC_SENSORC_SCM.csv
are:
Field | Description |
---|---|
scm_COR_R | The Skewness value of of line current R |
scm_IDM_R | The Kurtosis value of of line current R |
scm_ENT_R | The Variance value of of line current R |
scm_CSD_R | The RMS value of of line current R |
scm_CSR_R | The Skewness value of of line current S |
scm_DKL_R | The Kurtosis value of of line current S |
scm_MDR_R | The Variance value of of line current S |
scm_CAD_R | The RMS value of of line current S |