Notifications
You must be signed in to change notification settings - Fork 72
/
modbus-sma-SBn_n-1AV-40.py
executable file
·220 lines (216 loc) · 15.3 KB
/
modbus-sma-SBn_n-1AV-40.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
# Supported hardware and firmware:
# Sunny Boy 3.0 / 3.6 / 4.0 / 5.0
# Sunny Boy: SB3.0-1AV-40 / SB3.6-1AV-40 / SB4.0-1AV-40 / SB5.0-1AV-40
# Starting with software package: 01.03.04.R
# Full list of readable registers - comment out registers you aren't interested in for faster performance
#
# Descriptions generated by using the following formula in SMA_Modbus-TI-en-26.xlsx - available from SMA web site
# =" ['"&A3&" - "&IFERROR(LEFT(B3,FIND(":",B3)-1),B3)&IF(C3<>""," ("&C3&")","")&"',"&A3&",'"&D3&"','"&E3&"'],"
#
# Note: The following manual updates were made:
# * Updates from STR32 to STR16 as the SMA doco appears to be wrong for 31017, 31025, 31033, 31041, 40159, 40167, 40175 and 40513
# * Remove extended characters from temperatures in 30953, 34109 and 34113
# * Comment out write only registers: 40015, 40016, 40018, 40022, 40023, 40024, 40025 and 40999
sma_registers = [
['30051 - Device class',30051,'U32','ENUM'],
['30053 - Device type',30053,'U32','ENUM'],
['30057 - Serial number',30057,'U32','RAW'],
['30059 - Software package',30059,'U32','FW'],
['30199 - Waiting time until feed-in (s)',30199,'U32','Duration'],
['30201 - Condition',30201,'U32','ENUM'],
['30203 - Nominal power in Ok Mode (W)',30203,'U32','FIX0'],
['30205 - Nominal power in Warning Mode (W)',30205,'U32','FIX0'],
['30207 - Nominal power in Fault Mode (W)',30207,'U32','FIX0'],
['30211 - Recommended action',30211,'U32','ENUM'],
['30213 - Message',30213,'U32','ENUM'],
['30215 - Fault correction measure',30215,'U32','ENUM'],
['30217 - Grid relay/contactor',30217,'U32','ENUM'],
['30225 - Insulation resistance (Ohms)',30225,'U32','FIX0'],
['30231 - Maximum active power device (W)',30231,'U32','FIX0'],
['30233 - Set active power limit (W)',30233,'U32','FIX0'],
['30247 - Current event number for manufacturer',30247,'U32','FIX0'],
['30513 - Total yield (Wh)',30513,'U64','FIX0'],
['30517 - Daily yield (Wh)',30517,'U64','FIX0'],
['30521 - Operating time (s)',30521,'U64','Duration'],
['30525 - Feed-in time (s)',30525,'U64','Duration'],
['30529 - Total yield (Wh)',30529,'U32','FIX0'],
['30531 - Total yield (kWh)',30531,'U32','FIX0'],
['30533 - Total yield (MWh)',30533,'U32','FIX0'],
['30535 - Daily yield (Wh)',30535,'U32','FIX0'],
['30537 - Daily yield (kWh)',30537,'U32','FIX0'],
['30539 - Daily yield (MWh)',30539,'U32','FIX0'],
['30541 - Operating time (s)',30541,'U32','Duration'],
['30543 - Feed-in time (s)',30543,'U32','Duration'],
['30559 - Number of events for user',30559,'U32','FIX0'],
['30561 - Number of events for installer',30561,'U32','FIX0'],
['30563 - Number of events for service',30563,'U32','FIX0'],
['30581 - Grid reference counter reading (Wh)',30581,'U32','FIX0'],
['30583 - Grid feed-in counter reading (Wh)',30583,'U32','FIX0'],
['30599 - Number of grid connections',30599,'U32','FIX0'],
['30769 - DC current input [1] (A)',30769,'S32','FIX3'],
['30771 - DC voltage input [1] (V)',30771,'S32','FIX2'],
['30773 - DC power input [1] (W)',30773,'S32','FIX0'],
['30775 - Power (W)',30775,'S32','FIX0'],
['30783 - Grid voltage phase L1 (V)',30783,'U32','FIX2'],
['30785 - Grid voltage phase L2 (V)',30785,'U32','FIX2'],
['30787 - Grid voltage phase L3 (V)',30787,'U32','FIX2'],
['30803 - Grid frequency (Hz)',30803,'U32','FIX2'],
['30805 - Reactive power (VAr)',30805,'S32','FIX0'],
['30813 - Apparent power (VA)',30813,'S32','FIX0'],
['30823 - Excitation type of cosPhi',30823,'U32','ENUM'],
['30825 - Operating mode of stat.V stab., stat.V stab. config.',30825,'U32','ENUM'],
['30829 - Reactive power set value as a % (%)',30829,'S32','FIX1'],
['30831 - cosPhi setpoint, cosPhi config., direct specif.',30831,'S32','FIX2'],
['30833 - cosPhi excit.type, cosPhi config., direct spec.',30833,'U32','ENUM'],
['30835 - Operating mode of feed-in management',30835,'U32','ENUM'],
['30837 - Active power limitation P, active power configuration (W)',30837,'U32','FIX0'],
['30839 - Active power limitation P, active power configuration (%)',30839,'U32','FIX0'],
['30865 - Power grid reference (W)',30865,'S32','FIX0'],
['30867 - Power grid feed-in (W)',30867,'S32','FIX0'],
['30925 - Connection speed of SMACOM A',30925,'U32','ENUM'],
['30927 - Duplex mode of SMACOM A',30927,'U32','ENUM'],
['30929 - Speedwire connection status of SMACOM A',30929,'U32','ENUM'],
['30949 - Displacement power factor ',30949,'U32','FIX3'],
['30953 - Internal temperature (C)',30953,'S32','TEMP'],
['30957 - DC current input [2] (A)',30957,'S32','FIX3'],
['30959 - DC voltage input [2] (V)',30959,'S32','FIX2'],
['30961 - DC power input [2] (W)',30961,'S32','FIX0'],
['30975 - Intermediate circuit voltage (V)',30975,'S32','FIX2'],
['30977 - Grid current phase L1 (A)',30977,'S32','FIX3'],
['30979 - Grid current phase L2 (A)',30979,'S32','FIX3'],
['30981 - Grid current phase L3 (A)',30981,'S32','FIX3'],
['31017 - Current speedwire IP address',31017,'STR16','UTF8'],
['31025 - Current speedwire subnet mask',31025,'STR16','UTF8'],
['31033 - Current speedwire gateway address',31033,'STR16','UTF8'],
['31041 - Current speedwire DNS server address',31041,'STR16','UTF8'],
['31085 - Nominal power in Ok Mode (W)',31085,'U32','FIX0'],
['31247 - Residual current (A)',31247,'S32','FIX3'],
['34109 - Heat sink temperature (C)',34109,'S32','TEMP'],
['34113 - Internal temperature (C)',34113,'S32','TEMP'],
['35377 - Number of events for user',35377,'U64','FIX0'],
['35381 - Number of events for installer',35381,'U64','FIX0'],
['35385 - Number of events for service',35385,'U64','FIX0'],
['40003 - Time zone',40003,'U32','ENUM'],
['40005 - Standard/Daylight saving time conversion on',40005,'U32','ENUM'],
['40009 - Operating condition',40009,'U32','ENUM'],
['40013 - Language of the user interface',40013,'U32','ENUM'],
# ['40015 - Normalized reactive power limitation by PV system ctrl (%)',40015,'S16','FIX1'], # Write only
# ['40016 - Normalized active power limitation by PV system ctrl (%)',40016,'S16','FIX0'], # Write only
# ['40018 - Fast shut-down',40018,'U32','ENUM'], # Write only
# ['40022 - Normalized reactive power limitation by PV system ctrl (%)',40022,'S16','FIX2'], # Write only
# ['40023 - Normalized active power limitation by PV system ctrl (%)',40023,'S16','FIX2'], # Write only
# ['40024 - Dis.pow.factor that can be changed via PV system ctrl',40024,'U16','FIX4'], # Write only
# ['40025 - Excitation type that can be changed by PV system ctrl',40025,'U32','ENUM'], # Write only
['40063 - Firmware version of the main processor',40063,'U32','FW'],
['40067 - Serial number',40067,'U32','RAW'],
['40109 - Country standard set',40109,'U32','ENUM'],
['40133 - Grid nominal voltage (V)',40133,'U32','FIX0'],
['40135 - Nominal frequency (Hz)',40135,'U32','FIX2'],
['40157 - Automatic speedwire configureation switched on',40157,'U32','ENUM'],
['40159 - Speedwire IP address',40159,'STR16','IP4'],
['40167 - Speedwire subnet mask',40167,'STR16','IP4'],
['40175 - Speedwire gateway address',40175,'STR16','IP4'],
['40183 - Phase assignment',40183,'U32','ENUM'],
['40185 - Maximum apparent power device (VA)',40185,'U32','FIX0'],
['40195 - Currently set apparent power limit (VA)',40195,'U32','FIX0'],
['40200 - Operating mode of stat.V stab., stat.V stab. config.',40200,'U32','ENUM'],
['40204 - Reactive power set value as a % (%)',40204,'S32','FIX1'],
['40206 - cosPhi setpoint, cosPhi config., direct specif.',40206,'S32','FIX2'],
['40208 - cosPhi excit.type, cosPhi config., direct spec.',40208,'U32','ENUM'],
['40210 - Operating mode of feed-in management',40210,'U32','ENUM'],
['40212 - Active power limitation P, active power configuration (W)',40212,'U32','FIX0'],
['40214 - Active power limitation P, active power configuration (%)',40214,'U32','FIX0'],
['40216 - Operating mode of active power reduction in case of overfrequency P(f)',40216,'U32','ENUM'],
['40218 - Difference between starting frequency and grid frequency, linear instantaneous power gradient configuration (Hz)',40218,'U32','FIX2'],
['40220 - Difference between reset frequency and grid frequency, linear instantaneous power gradient configuration (Hz)',40220,'U32','FIX2'],
['40222 - cosPhi at start point, cosPhi(P) char. config.',40222,'U32','FIX2'],
['40224 - Excit. type at start point, cosPhi(P) char. conf.',40224,'U32','ENUM'],
['40226 - cosPhi at end point, cosPhi(P) char. config.',40226,'U32','FIX2'],
['40228 - Excit. type at end point, cosPhi(P) char. config.',40228,'U32','ENUM'],
['40230 - Act. power at start point, cosPhi(P) char. config. (%)',40230,'U32','FIX0'],
['40232 - Act. power at end point, cosPhi(P) char. config. (%)',40232,'U32','FIX0'],
['40238 - Active power gradient, linear instantaneous power gradient configuration (%)',40238,'U32','FIX0'],
['40240 - Activation of stay-set indicator function, linear instantaneous power gradient configuration',40240,'U32','ENUM'],
['40242 - Active power gradient after reset frequency, linear instantaneous power gradient configuration (%)',40242,'U32','FIX0'],
['40428 - Frequency monitoring median maximum threshold (Hz)',40428,'U32','FIX2'],
['40430 - Frq. monitoring median max. threshold trip. time (ms)',40430,'U32','FIX0'],
['40432 - Frequency monitoring lower maximum threshold (Hz)',40432,'U32','FIX2'],
['40434 - Frq. monitoring lower max. threshold trip. time (ms)',40434,'U32','FIX0'],
['40436 - Frequency monitoring upper minimum threshold (Hz)',40436,'U32','FIX2'],
['40438 - Frq. monitoring upper min. threshold trip. time (ms)',40438,'U32','FIX0'],
['40440 - Frequency monitoring median minimum threshold (Hz)',40440,'U32','FIX2'],
['40442 - Frq. monitoring median min. threshold trip. time (ms)',40442,'U32','FIX0'],
['40448 - Voltage monitoring median maximum threshold (V)',40448,'U32','FIX2'],
['40450 - Voltage monitoring median max. threshold trip.time (ms)',40450,'U32','FIX0'],
['40452 - Voltage monitoring lower maximum threshold (V)',40452,'U32','FIX2'],
['40456 - Voltage monitoring lower max. threshold trip. time (ms)',40456,'U32','FIX0'],
['40458 - Voltage monitoring lower minimum threshold (V)',40458,'U32','FIX2'],
['40462 - Voltage monitoring lower min. threshold trip. time (ms)',40462,'U32','FIX0'],
['40464 - Voltage monitoring of median minimum threshold (V)',40464,'U32','FIX2'],
['40466 - Voltage monitoring median min. threshold trip.time (ms)',40466,'U32','FIX0'],
['40470 - Island network detect. status',40470,'U32','ENUM'],
['40484 - Activation of active power gradient',40484,'U32','ENUM'],
['40497 - MAC address',40497,'STR32','UTF8'],
['40513 - Speedwire DNS server address',40513,'STR16','IP4'],
['40631 - Device name',40631,'STR32','UTF8'],
['40789 - Communication version',40789,'U32','REV'],
['40915 - Set active power limit (W)',40915,'U32','FIX0'],
# ['40999 - Setpoint cos(phi) as per EEI convention',40999,'S32','FIX4'], # Write only
['41017 - Adjustment time of characteristic operating point, conf. of grid integr. char. 1 (s)',41017,'U32','FIX1'],
['41023 - Number of points to be used, conf. of grid integr. char. 1',41023,'U32','FIX0'],
['41025 - X-axes reference, conf. of grid integration char. 1',41025,'U32','ENUM'],
['41027 - Y-axes reference, conf. of grid integration char. 1',41027,'U32','ENUM'],
['41029 - X value 1, conf. of grid integr. char. 1',41029,'S32','FIX3'],
['41031 - Y value 1, conf. of grid integr. char. 1',41031,'S32','FIX3'],
['41033 - X value 2, conf. of grid integr. char. 1',41033,'S32','FIX3'],
['41035 - Y value 2, conf. of grid integr. char. 1',41035,'S32','FIX3'],
['41037 - X value 3, conf. of grid integr. char. 1',41037,'S32','FIX3'],
['41039 - Y value 3, conf. of grid integr. char. 1',41039,'S32','FIX3'],
['41041 - X value 4, conf. of grid integr. char. 1',41041,'S32','FIX3'],
['41043 - Y value 4, conf. of grid integr. char. 1',41043,'S32','FIX3'],
['41061 - 2nd characteristic curve number, configuration of characteristic curve mode',41061,'U32','FIX0'],
['41063 - 2nd activation of the characteristic curve, configuration of characteristic curve mode',41063,'U32','ENUM'],
['41065 - Adjustment time of char. operating point, conf. of grid integration char. 2 (s)',41065,'U32','FIX1'],
['41071 - Number of points to be used, conf. of grid integr. char. 2',41071,'U32','FIX0'],
['41073 - Input unit, conf. of grid integration char. 2',41073,'U32','ENUM'],
['41075 - Output frequency, conf. of grid integration char. 2',41075,'U32','ENUM'],
['41077 - X value 1, conf. of grid integr. char. 2',41077,'S32','FIX3'],
['41079 - Y value 1, conf. of grid integr. char. 2',41079,'S32','FIX3'],
['41081 - X value 2, conf. of grid integr. char. 2',41081,'S32','FIX3'],
['41083 - Y value 2, conf. of grid integr. char. 2',41083,'S32','FIX3'],
['41085 - X value 3, conf. of grid integr. char. 2',41085,'S32','FIX3'],
['41087 - Y value 3, conf. of grid integr. char. 2',41087,'S32','FIX3'],
['41089 - X value 4, conf. of grid integr. char. 2',41089,'S32','FIX3'],
['41091 - Y value 4, conf. of grid integr. char. 2',41091,'S32','FIX3'],
['41111 - Voltage monitoring of lower minimum threshold as RMS value (V)',41111,'U32','FIX2'],
['41113 - Voltage monitoring of lower min.threshold as RMS value for tripping time (ms)',41113,'U32','FIX0'],
['41115 - Voltage monitoring of upper maximum threshold as RMS value (V)',41115,'U32','FIX2'],
['41117 - Voltage monitoring of upper max. thresh. as RMS value for tripping time (ms)',41117,'U32','FIX0'],
['41121 - Set country standard',41121,'U32','FUNKTION_SEC'],
['41123 - Min. voltage for reconnection (V)',41123,'U32','FIX2'],
['41125 - Max. voltage for reconnection (V)',41125,'U32','FIX2'],
['41127 - Lower frequency for reconnection (Hz)',41127,'U32','FIX2'],
['41129 - Upper frequency for reconnection (Hz)',41129,'U32','FIX2'],
['41169 - Minimum insulation resistance (Ohms)',41169,'U32','FIX0'],
['41171 - Set total yield (kWh)',41171,'U32','FIX0'],
['41173 - Set total operating time at grid connection point (h)',41173,'U32','Duration'],
['41193 - Operating mode for absent active power limitation',41193,'U32','ENUM'],
['41195 - Timeout for absent active power limitation (s)',41195,'U32','Duration'],
['41197 - Fallback act power lmt P in % of WMax for absent act power lmt (%)',41197,'U32','FIX2'],
['41199 - Set active power limit at grid connection point (%)',41199,'U32','FIX0'],
['41203 - Nominal PV system power (W)',41203,'U32','FIX0'],
['41217 - Set active power limit at grid connection point (W)',41217,'U32','FIX0'],
['41219 - Operating mode for absent reactive power control',41219,'U32','ENUM'],
['41221 - Timeout for absent reactive power control (s)',41221,'U32','Duration'],
['41223 - Fallback react power Q in % of WMax for absent react power ctr (%)',41223,'S32','FIX2'],
['41225 - Operating mode for absent cos Phi spec',41225,'U32','ENUM'],
['41227 - Timeout for absent cos Phi spec (s)',41227,'U32','Duration'],
['41229 - Fallback cos Phi for absent cos Phi spec',41229,'S32','FIX4'],
['41253 - Fast shut-down',41253,'U32','ENUM'],
['41255 - Normalized active power limitation by PV system ctrl (%)',41255,'S16','FIX2'],
['41256 - Normalized reactive power limitation by PV system ctrl (%)',41256,'S16','FIX2'],
['41257 - Setpoint cos(phi) as per EEI convention',41257,'S32','FIX4'],
['43090 - Login with Grid Guard-Code',43090,'U32','FIX0']
]
# scan is not used for SMA inverters but solariot.py expects it to exist
scan = "{}"