<?php
/**
* power status module class
*
* @package munkireport
* @author
**/
class Power_controller extends Module_controller
{
/*** Protect methods with auth! ****/
public function __construct()
{
// Store module path
$this->module_path = dirname(__FILE__);
}
/**
* Default method
*
* @author AvB
**/
public function index()
{
echo "You've loaded the power module!";
}
/**
* Get Power Statistics
*
*
**/
public function get_stats()
{
$obj = new View();
$pm = new Power_model;
$out[] = $pm->get_stats();
$obj->view('json', array('msg' => $out));
}
/**
* Get conditions
*
* @return void
* @author AvB
**/
public function conditions()
{
$obj = new View();
$queryobj = new Power_model();
$sql = "SELECT COUNT(CASE WHEN `condition` = 'Normal' OR `condition` = 'Good' THEN 1 END) AS good,
COUNT(CASE WHEN `condition` = 'Service Battery' OR `condition` = 'ServiceBattery' OR `condition` = 'Check Battery' THEN 1 END) AS service,
COUNT(CASE WHEN `condition` = 'Replace Soon' OR `condition` = 'ReplaceSoon' OR `condition` = 'Fair' THEN 1 END) AS fair,
COUNT(CASE WHEN `condition` = 'Replace Now' OR `condition` = 'ReplaceNow' OR `condition` = 'Poor' THEN 1 END) AS poor,
COUNT(CASE WHEN `condition` = 'No Battery' OR `condition` = 'NoBattery' THEN 1 END) AS missing
FROM power
LEFT JOIN reportdata USING (serial_number)
".get_machine_group_filter();
$obj->view('json', array('msg' => current($queryobj->query($sql))));
}
/**
* Retrieve data in json format
*
**/
public function get_data($serial_number = '')
{
$serial_number = preg_replace("/[^A-Za-z0-9_\-]]/", '', $serial_number);
$sql = "SELECT `manufacture_date`, `design_capacity`, `max_capacity`, `max_percent`, `current_capacity`, `current_percent`, `cycle_count`, `designcyclecount`, `condition`, `temperature`, `externalconnected`, `ischarging`, `fullycharged`, `avgtimetofull`, `avgtimetoempty`, `timeremaining`, `instanttimetoempty`, `amperage`, `voltage`, `cellvoltage`, `permanentfailurestatus`, `manufacturer`, `batteryserialnumber`, `packreserve`, `wattage`, `adapter_name`, `adapter_manufacturer`, `adapter_current`, `adapter_voltage`, `adapter_id`, `family_code`, `adapter_serial_number`, `ups_name`, `ups_percent`, `ups_charging_status`, `haltlevel`, `haltafter`, `haltremain`, `active_profile`, `schedule`, `sleep_count`, `dark_wake_count`, `user_wake_count`, `standbydelay`, `standby`, `womp`, `halfdim`, `hibernatefile`, `gpuswitch`, `sms`, `networkoversleep`, `disksleep`, `sleep`, `autopoweroffdelay`, `hibernatemode`, `autopoweroff`, `ttyskeepawake`, `displaysleep`, `acwake`, `lidwake`, `sleep_on_power_button`, `powernap`, `autorestart`, `destroyfvkeyonstandby`, `cpu_scheduler_limit`, `cpu_available_cpus`, `cpu_speed_limit`, `combined_sys_load`, `user_sys_load`, `battery_level`, `thermal_level`, `backgroundtask`, `applepushservicetask`, `userisactive`, `preventuseridledisplaysleep`, `preventsystemsleep`, `externalmedia`, `preventuseridlesystemsleep`, `networkclientactive`, `sleep_prevented_by`
FROM power
WHERE serial_number = '$serial_number'";
$queryobj = new Power_model;
$power_data = $queryobj->query($sql)[0];
$temp_format = conf('temperature_unit');
$power_data->temp_format = $temp_format; // Add the temp format for use in the client tab's JavaScript
jsonView($power_data);
}
} // END class Power_controller