MetroAE always requires VSC system interface to be UP, even when no system_ip is set #1456

Open
jbemmel opened this issue Apr 3, 2020 · 1 comment

Comments

@jbemmel
Copy link
Collaborator

jbemmel commented Apr 3, 2020

The VSC healthcheck prevents a successful upgrade in case a VSC configuration is used which has no system_ip

@fab-r-a
Copy link
Collaborator

fab-r-a commented Nov 13, 2020

If possible could this be changed on new system deployment also? It's very common to not use system interface, avoiding the need to have an IGP to allow this interface connectivity. So the target is to use control interface IP as BGP source address instead of system IP.