Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Incorrect Depth Scaling #194

Open
spok7 opened this issue Sep 12, 2023 · 1 comment
Open

Incorrect Depth Scaling #194

spok7 opened this issue Sep 12, 2023 · 1 comment

Comments

@spok7
Copy link

spok7 commented Sep 12, 2023

While trying to create a static tf publisher between my depth cameras (Astra Pro Plus, D435i, D430, D430), I noticed a discrepancy between the Astra Pro Plus and the D435i when viewing the RGB depth clouds in rviz's TopDownOrtho view:

image-20230912125906285

The rectangular fume hood shown by the Astra camera (gray) appears much smaller than in the D435i Realsense (green). After measuring it manually, it seems like the realsense is showing the correct scale, whereas the astra is showing it at ~85% scale. And yes, all of the cameras' intrinsics have been calibrated.

Is there any way of manually adjusting the distance/depth/z scaling through the ROS package? If not, is there a way of doing this via firmware?

@spok7
Copy link
Author

spok7 commented Sep 12, 2023

Alternate views in Orbit mode, for clarity:
image
image
image

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment