Simple control modules

Description

Install this package

Enter:

apax add @simatic-ax/simple-control-modules

to install this package you need to login into the GitHub registry. You'll find more information here

Namespace

Simatic.Ax.SimpleControlModules

Encoder

Encoder A

The EncoderA counts the rising and falling edges of a binary signal.

EncoderAB

The EncoderAB is similar to EnocderA but it counts the rising and falling edges of two 90 dregree phase shifted binary signals (SignalA and SignalB). So the counting direction is evaluated automatically.

Methods of EncoderA and EncoderAB

Evaluate() Evaluate the SignalA for rising and falling edges and counts them
GetValue() : DINT Returns the actual counter value
RelativeCount() Retunrs the relative counter value
Reset Reset the counter value to 0
ResetRelative() Reset the relative counter value to 0
SetDirection(mode : CountMode) Set the counting direction FORWARD or REVERSE
SetValue(value : DINT) Set the actual counter value to value

Configuration:

USING Siemens.Ax.IO.Input;
USING Simatic.Ax.SimpleControlModules;

VAR_GLOBAL
    sigA : BinSignal;
    enc : EncoderAB(SignalA := sigA);
END_VAR

Configuration:

USING Siemens.Ax.IO.Input;
USING Simatic.Ax.SimpleControlModules;

VAR_GLOBAL
    sigA : BinSignal;
    sigB : BinSignal;
    enc : EncoderAB(SignalA := sigA, SignalB := sigB);
END_VAR

Example

USING Siemens.Ax.Io.Input;
USING Simatic.Ax.SimpleControlModules;

CONFIGURATION PLC_1

    TASK Main(Priority := 1);

    PROGRAM P1 WITH Main : SampleProgram;

    VAR_GLOBAL
        aIn AT %I0.0 : BOOL ;
        bIn AT %I0.0 : BOOL ;
        sigA : BinSignal;
        sigB : BinSignal;
        actPos : DINT;
        enc : EncoderAB := (SignalA := sigA, SignalB := sigB);
    END_VAR
    
END_CONFIGURATION

PROGRAM SampleProgram
    VAR_EXTERNAL
        aIn : BOOL ;
        bIn : BOOL ;
        sigA : BinSignal;
        sigB : BinSignal;
        actPos : DINT;
        enc : EncoderAB;
    END_VAR

    sigA.ReadCyclic(signal := aIn);
    sigB.ReadCyclic(signal := bIn);
    enc.Evaluate();
    actPos := enc.GetValue();
END_PROGRAM

Counter

The Counter counts with the methods CountForward(increment : DINT) or CountReverse(decrement : DINT). The parameter increment or decrement is 1 by default.

Methods:

Config(ll : DINT ul : DINT) set the upper and lower limit
SetCounterValue(value : DINT) Set the counterf value to value (default 0)
CounterValue() : DINT Retunrs the actual counter value
CountForward(increment : DINT) Count forward by increment (default 1)
CountReverse(decrement : DINT) Count reverse by decrement (default 1)
UpperLimitReached() : BOOL Returns TRUE when the counter value >= upper limit
LowerLimitReached() : BOOL Returns TRUE when the counter value <= lower limit

Markdownlint-cli

This workspace will be checked by the markdownlint-cli (there is also documented ho to install the tool) tool in the CI workflow automatically.
To avoid, that the CI workflow fails because of the markdown linter, you can check all markdown files locally by running the markdownlint with:

markdownlint **/*.md --fix