5.8

28 Oct 07:30
Compare
Choose a tag to compare

Mavericks 10.9 compatible

5.7.1

07 Sep 07:26
Compare
Choose a tag to compare

Minor GUI corrections, and optimizations

5.7

04 Aug 06:39
Compare
Choose a tag to compare
5.7
  • OsiriX MD is FDA / CE certified as Medical Device Class II
  • DICOM: Support for Breast Tomosynthesis Image Storage
  • DICOM: Support UTF8 string for ROI description box, instead of ASCII 127 only
  • DICOM: Support for SUV calculation on PET series with decayCorrection NONE and ADMIN
  • DICOM: Support for EnhancedUSVolumeStorage
  • DICOM: Support for EncapsulatedCDAStorage
  • DICOM: Support for EstimatedRadiographicMagnificationFactor
  • DICOM: Merge Studies: option to modify DICOM files
  • DICOM: Query Retrieve window: Option to have smaller refresh intervals
  • DICOM: WADO Retrieve: Start retrieving before C-FIND ends
  • DICOM: Multiple associations during DICOM STORE-SCU (DICOM Send)
  • PACS On-Demand: Automatically retrieve partial studies
  • PACS On-Demand: Support for next/previous patient
  • PACS On-Demand: Support for last name and first name searches
  • ROI: Anti-aliased ROI text rendering
  • ROI: Display radii for Circle ROIs
  • ROI: Option to display ROI info, only when mouse is over
  • ROI: 90, 45, 0 lines drawing when pressing shift key
  • ROI: Support alpha pixel for tBrush selection
  • ROI: Compute skewness / kurtosis
  • ROI: Display units, if available
  • ROI: Support ROI mean, min, max calculation for RGB images
  • 3D Curved-MPR: Display transverse lines with real size according to transverse view zoom level
  • 3D Curved-MPR: Option to enter thickness manually (similar to MPR)
  • 3D Curved-MPR: Export window: option to enter the slice interval, manually
  • Database: Add 'Day Before Yesterday' option for Smart Albums
  • Database: Display both ages: actual and at time of study
  • Database: Faster Database delete process
  • Database: Display progress bar for WADO download
  • 2D viewer: Next/Previous Patient button: load workspace state if available
  • 2D viewer: Display if VOI LUT is applied or available
  • 2D viewer: Display the thickness in mm
  • 2D Viewer: Always order the windows from most recent study to oldest study
  • 2D Viewer: Display study color / number, based on all available studies, not only on displayed studies
  • 2D Viewer: Display overflow lines if raw data is not completely displayed in the view
  • Hanging Protocols: Support for comparatives
  • Preferences: Centralized Defaults Preferences
  • Preferences: Limit auto-comments to study or series level
  • Preferences: Activate checkbox for DICOM nodes
  • Preferences: Erase entire DB at each startup / quit
  • Preferences: Completely ignore CD/DVD
  • WebPortal: For administrators: delete studies and consult network logs
  • WebPortal: Other studies for a patient: Sorted by Date
  • WebPortal: Flash sequence: double-click on the image to auto-play / stop
  • WebPortal: Flash sequence: Play movie at defined frameRate WebPortal: Recent patients list
  • WebPortal: Faster algorithm for displaying the users list allowed to view a study
  • WebPortal: Progress indicator when uploading a file