Notifications
You must be signed in to change notification settings - Fork 1
/
Program_biosignalsPluxPro.cs
192 lines (144 loc) · 6.68 KB
/
Program_biosignalsPluxPro.cs
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
// "C:\\Program Files (x86)\\Microsoft Visual Studio\\2017\\Community\\MSBuild\\15.0\\Bin\\Roslyn\\csc.exe" -reference:plux.dll Program_biosignalsPluxPro+.cs -out:"Program.exe"
// Program.exe scan Run app scanning for devices (save output on log file)
// Program.exe BTH58:8E:81:A2:41:A6 > "log.txt" Run app connecting to specific device (save output on log file)
using System.Collections.Generic;
using System;
using System.Threading.Tasks;
public class MyDevice : PluxDotNet.SignalsDev
{
public MyDevice(string path) : base(path) {}
public override bool OnRawFrame(int nSeq, int[] data)
{
if (nSeq % freq == 0)
{ // here once per second
// print one frame
System.Console.Write("[" + DateTime.Now + "]");
System.Console.Write(" {0} -", nSeq);
foreach (int val in data)
System.Console.Write(" {0}", val);
System.Console.WriteLine();
if (System.Console.KeyAvailable)
return true; // if a key was pressed, exit loop
}
return false;
}
public override bool OnEvent(PluxDotNet.Event.Event evt)
{
PluxDotNet.Event.Battery evtBat = evt as PluxDotNet.Event.Battery;
if (evtBat != null)
{
System.Console.WriteLine("Battery event - voltage: {0} V ; charge remaining: {1} %",
evtBat.voltage, evtBat.percentage);
return false;
}
PluxDotNet.Event.SignalGood evtSigGood = evt as PluxDotNet.Event.SignalGood;
if (evtSigGood != null)
{
System.Console.WriteLine("Signal state event - port: {0} ; is good: {1}",
evtSigGood.port, evtSigGood.isGood);
return false;
}
System.Console.WriteLine(evt);
return false;
}
/*
// only needed if timeouts are used
public override bool OnTimeout()
{
return true;
}
// only needed if interrupts are used
public override bool OnInterrupt(object param)
{
return true;
}
*/
public int freq;
}
class Program
{
static void Main(string[] args)
{
try
{
// Device MAC address
string macAddr = null;
if (args.Length > 0) {
if(String.Compare(args[0], "scan", true) == 0) {
// Search for Plux devices in range and use the first found
System.Console.WriteLine("Scanning for devices...");
List<PluxDotNet.DevInfo> devs = PluxDotNet.BaseDev.FindDevices();
if (devs.Count > 0) {
System.Console.WriteLine("Devices found:");
foreach (PluxDotNet.DevInfo devInfo in devs)
System.Console.WriteLine(" * {0} - {1}", devInfo.path, devInfo.description);
macAddr = devs[0].path;
} else {
System.Console.WriteLine("No devices found.");
System.Environment.Exit(1);
}
} else {
// Device MAC address:
macAddr = args[0];
//macAddr = "BTH58:8E:81:A2:41:A6"; // replace with your device MAC address
//macAddr = "BLE58:8E:81:A2:41:A6";
//macAddr = "COM48";
}
} else {
//System.Console.WriteLine(" ERROR: NULL input parameter. \n Please define device MAC address as input parameter or 'scan' keyword to search for Plux devices in range");
}
if (!String.IsNullOrEmpty(macAddr)) {
System.Console.WriteLine("Connecting to {0}...", macAddr);
// Example without "using" keyword - need to call Dispose() at the end
MyDevice dev = new MyDevice(macAddr);
Dictionary<string, object> props = dev.GetProperties();
System.Console.WriteLine("Device description: {0} - {1}", props["description"], props["path"]);
dev.freq = 200; // acquisition base frequency of 200 Hz
if (props["description"].ToString() == "biosignalsplux") {
// (connecting to biosignalsplux Device)
// start acquisition (CH1-CH4 acquisition, 16-bits)
//dev.Start(dev.freq, 0x0F, 16);
// Setting sensor sources individually...
PluxDotNet.Source src_emg1 = new PluxDotNet.Source();
src_emg1.port = 1; // EMG source port
// src_emg1.freqDivisor kept at default value of 1
// src_emg1.chMask kept at default value of 1 (channel 1 only)
// src_emg1.nBits kept at default value of 16
PluxDotNet.Source src_emg2 = new PluxDotNet.Source();
src_emg2.port = 2; // EMG source port
// src_emg2.freqDivisor kept at default value of 1
// src_emg2.chMask kept at default value of 1 (channel 1 only)
// src_emg2.nBits kept at default value of 16
PluxDotNet.Source src_ecg = new PluxDotNet.Source();
src_ecg.port = 3; // ECG source port
// src_ecg.freqDivisor kept at default value of 1
// src_ecg.chMask kept at default value of 1 (channel 1 only)
// src_ecg.nBits kept at default value of 16
// ...
PluxDotNet.Source src_spo2 = new PluxDotNet.Source();
src_spo2.port = 5; // SPO2 source port
src_spo2.chMask = 0x03; // One-pair of leds (Red + IR)
List<PluxDotNet.Source> srcs = new List<PluxDotNet.Source>() { src_emg1, src_emg2, src_ecg, src_spo2 };
int[] LED_param = {80, 40}; // LED values (0-255). Default values:
// * Head band -> Red = 80, IR = 40;
// * Arm band -> Red = 4, IR = 2;
dev.SetParameter(0x05, 0x03, LED_param, 2); // update oximeter LED values (Red and IR)
dev.Start(dev.freq, srcs); // start acquisition
System.Console.WriteLine("Acquisition started. Press a key to stop.");
dev.Loop(); // run message loop
dev.Stop(); // stop acquisition
} else {
System.Console.WriteLine("Device is not a biosignalsplux: {0}", props["description"]);
}
dev.Dispose(); // disconnect from device
} else {
System.Console.WriteLine(" ERROR: NULL input parameter. \n Please define device MAC address as input parameter or 'scan' keyword to search for Plux devices in range");
}
}
catch (PluxDotNet.Exception.PluxException e)
{
System.Console.WriteLine("Exception: {0}", e.Message);
//System.Console.WriteLine("Exception: {0} - {1}:{2} ({3})", e.Message, e.file, e.line, e.function);
}
}
}