Notifications
You must be signed in to change notification settings - Fork 2
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
Signed-off-by: Peter Mitri <peter.mitri@rte-france.com>
- Loading branch information
Showing
11 changed files
with
657 additions
and
0 deletions.
There are no files selected for viewing
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,193 @@ | ||
# CIM GLSK | ||
|
||
GLSK in CIM format are defined within XML files. This format is used for the SWE region. | ||
The main tag of the document is **GLSK_MarketDocument**. | ||
|
||
## Header | ||
|
||
~~~xml | ||
<?xml version="1.0" encoding="UTF-8"?> | ||
<GLSK_MarketDocument xmlns="urn:iec62325.351:tc57wg16:451-n:glskdocument:2:1" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="urn:iec62325.351:tc57wg16:451-n:glskdocument:2:1 iec62325-451-n-glsk_v2_1.xsd"> | ||
<mRID>DOCUMENT_ID</mRID> | ||
<revisionNumber>1</revisionNumber> | ||
<type>B22</type> | ||
<process.processType>A48</process.processType> | ||
<sender_MarketParticipant.mRID codingScheme="A01">SENDER_EIC</sender_MarketParticipant.mRID> | ||
<sender_MarketParticipant.marketRole.type>A36</sender_MarketParticipant.marketRole.type> | ||
<receiver_MarketParticipant.mRID codingScheme="A01">RECEIVER_EIC</receiver_MarketParticipant.mRID> | ||
<receiver_MarketParticipant.marketRole.type>A04</receiver_MarketParticipant.marketRole.type> | ||
<createdDateTime>2002-06-15T15:49:00Z</createdDateTime> | ||
<status> | ||
<value>A42</value> | ||
</status> | ||
<time_Period.timeInterval> | ||
<start>2002-06-16T22:00Z</start> | ||
<end>2002-06-17T22:00Z</end> | ||
</time_Period.timeInterval> | ||
<domain.mRID codingScheme="A01">REGION_EIC</domain.mRID> | ||
... | ||
</GLSK_MarketDocument> | ||
~~~ | ||
|
||
Contents of the header: | ||
- **mRID**: ID for the document | ||
- **revisionNumber**: version of the document | ||
- **type**: standard code defining the document type*. In the example above, "B22" means "Generation and load shift keys document". | ||
- **process.processType**: standard code defining the process type*. In the example above, "A48" means "Day-ahead capacity determination". | ||
- **sender_MarketParticipant.mRID**: ID of the sender of the GLSK document*. Type is given by the content of **codingScheme**: | ||
- A01: the coding scheme is the [EICode](https://www.entsoe.eu/data/energy-identification-codes-eic/), maintained by ENTSO-E. | ||
- A02: the coding scheme used for Common Grid Model Exchange Standard (CGMES). | ||
- A10: the coding scheme for the preceding attribute is the Global Location Number (GLN 13) or Global Service Relation Number (GSRN 18), maintained by GS1. | ||
- ... other region-specific codes*. | ||
- **sender_MarketParticipant.marketRole.type**: standard code defining the role of the sender*. In the example above, "A36" means "capacity coordinator". | ||
- **receiver_MarketParticipant.mRID**: ID of the receiver of the GLSK document*. Type is given by the content of **codingScheme**. | ||
- **receiver_MarketParticipant.marketRole.type**: standard code defining the role of the receiver*. In the example above, "A04" means "system operator". | ||
- **createdDateTime**: document creation time. | ||
- **status**: standard code defining the status of the document type*. In the example above, "A42" means "The network data provided in the document or series concerns the whole area described by the document or series". | ||
- **time_Period.timeInterval**: time interval of applicability of the GLSK document. | ||
- **domain.mRID**: ID of the geographical applicability of the document. Type is given by the content of **codingScheme**. | ||
|
||
_*Refer to the [ENTSO-E website](https://www.entsoe.eu/publications/electronic-data-interchange-edi-library/) for the | ||
complete reference documents._ | ||
_You can find a complete list of codes [in the XSDs](https://www.entsoe.eu/Documents/EDI/Library/CIM_xsd_package.zip)._ | ||
|
||
## GLSK Definition | ||
|
||
Proper GLSK are defined within the tags **TimeSeries**. Usually every TSO defines its GLSK in one separate | ||
**TimeSeries** tag. | ||
|
||
~~~xml | ||
<TimeSeries> | ||
<mRID>TSO-TimeSeries-1</mRID> | ||
<subject_Domain.mRID codingScheme="A01">AREA_EIC</subject_Domain.mRID> | ||
<curveType>A03</curveType> | ||
<Period> | ||
<timeInterval> | ||
<start>2018-03-27T22:00Z</start> | ||
<end>2018-03-28T22:00Z</end> | ||
</timeInterval> | ||
<resolution>PT60M</resolution> | ||
<Point> | ||
<position>1</position> | ||
<SKBlock_TimeSeries> | ||
<businessType>...</businessType> | ||
... | ||
</SKBlock_TimeSeries> | ||
</Point> | ||
</Period> | ||
</TimeSeries> | ||
~~~ | ||
|
||
Contents of this tag: | ||
- **mRID**: unique ID of this **TimeSeries** | ||
- **subject_Domain.mRID**: ID of the area of applicability of this GLSK definition. Type is given by the content of **codingScheme**. | ||
- **curveType**: five possible values: | ||
- **A01**: the curve is made of successive Intervals of time (Blocks) of constant duration (size), where the size of the Blocks is equal to the Resolution of the Period. | ||
- **A02**: the curve is made of successive instants of time** (Points). | ||
- **A03**: the curve is made of successive Intervals of time (Blocks) of variable duration (size), where the end date and end time of each Block are equal to the start date and start time of the next Interval. For the last Block the end date and end time of the last Interval would be equal to EndDateTime of TimeInterval. | ||
- **A04**: the curve is made of successive Intervals of time of variable duration (size), where the end date and end time of each interval are equal to the start date and start time of the next Interval. | ||
- **A05**: the curve is a restriction of the curve type A04, i.e. overlapping breakpoints. The restriction is that a single Period is allowed. | ||
- **Period**: contains the GLSK values for different points in time | ||
- **timeInterval**: applicability timeframe of the current **Period** tag | ||
- **resolution**: time-step resolution of following **Point** tags (ISO 8601). In the example above, "PT60M" means 60 minutes. | ||
- **Point**: contains the GLSK values for a specific point inside the **timeInterval** | ||
- **position**: position of the point in the **timeInterval**, considering the **resolution**, and the convention defined in **curveType** | ||
- **SKBlock_TimeSeries**: actual GLSK definition for the given point in time. Their type is defined by **businessType**, which | ||
can have different values. We will detail the following values: | ||
- **B42**: Base case proportional shift key. In this case only one **SKBlock_TimeSeries** should be defined. | ||
- **B43**: Proportional to participation factors shift key. In this case only one **SKBlock_TimeSeries** should be defined. | ||
- **B44**: Proportional to the remaining capacity shift key. In this case only one **SKBlock_TimeSeries** should | ||
be defined. _(Note: this type is actually not supported by PowSyBl.)_ | ||
- **B45**: Merit order shift key. In this case multiple **SKBlock_TimeSeries** can be defined. | ||
|
||
### Base case proportional shift key | ||
|
||
When **businessType** is B42, the GSK or LSK are proportional to the base case generation or load. | ||
This type of GLSK is [described here](/input-data/glsk/glsk.md#proportional-to-target-power-glsk). | ||
|
||
~~~xml | ||
<SKBlock_TimeSeries> | ||
<businessType>B42</businessType> | ||
<mktPSRType.psrType>A04</mktPSRType.psrType> | ||
<measurement_Unit.name>C62</measurement_Unit.name> | ||
</SKBlock_TimeSeries> | ||
~~~ | ||
|
||
- **businessType**: B42 means "The GSK or LSK are proportional to the base case generation or load" | ||
- **mktPSRType.psrType**: standard code defining the network elements on which the shifting should operate: | ||
- **A04**: generators | ||
- **A05**: loads | ||
- **measurement_Unit.name**: unit of the GLSK. Only "C62" (dimensionless) is possible in this case. | ||
|
||
### Proportional to participation factors shift key | ||
|
||
When **businessType** is B43, the GSK or LSK are proportional to the participation factors. | ||
This type of GLSK is [described here](/input-data/glsk/glsk.md#equally-balanced-glsk). | ||
|
||
~~~xml | ||
<SKBlock_TimeSeries> | ||
<businessType>B43</businessType> | ||
<mktPSRType.psrType>A04</mktPSRType.psrType> | ||
<measurement_Unit.name>C62</measurement_Unit.name> | ||
</SKBlock_TimeSeries> | ||
~~~ | ||
- **businessType**: B43 means "The GSK or LSK are proportional to the participation factors" | ||
- **mktPSRType.psrType**: standard code defining the network elements on which the shifting should operate: | ||
- **A04**: generators | ||
- **A05**: loads | ||
- **measurement_Unit.name**: unit of the GLSK. Only "C62" (dimensionless) is possible in this case. | ||
|
||
### Proportional to the remaining capacity shift key | ||
When **businessType** is B44, the GSK is proportional to the remaining available capacity. | ||
This type of GLSK is [described here](/input-data/glsk/glsk.md#proportional-to-remaining-capacity). | ||
|
||
~~~xml | ||
<SKBlock_TimeSeries> | ||
<businessType>B44</businessType> | ||
<mktPSRType.psrType>A04</mktPSRType.psrType> | ||
<measurement_Unit.name>C62</measurement_Unit.name> | ||
</SKBlock_TimeSeries> | ||
~~~ | ||
|
||
- **businessType**: B44 means "The GSK is proportional to the remaining available capacity" | ||
- **mktPSRType.psrType**: standard code defining the network elements on which the shifting should operate: | ||
- **A04**: generators | ||
- **A05**: loads | ||
- **measurement_Unit.name**: unit of the GLSK. Only "C62" (dimensionless) is possible in this case. | ||
|
||
### Merit order shift key | ||
|
||
When **businessType** is B45, the GSK is proportional to a merit order list. | ||
This type of GLSK is [described here](/input-data/glsk/glsk.md#merit-order-glsk). | ||
|
||
~~~xml | ||
<SKBlock_TimeSeries> | ||
<businessType>B45</businessType> | ||
<mktPSRType.psrType>A04</mktPSRType.psrType> | ||
<flowDirection.direction>A01</flowDirection.direction> | ||
<measurement_Unit.name>MAW</measurement_Unit.name> | ||
<attributeInstanceComponent.position>3</attributeInstanceComponent.position> | ||
<RegisteredResource> | ||
<mRID codingScheme="A02">RESOURCE_ID</mRID> | ||
<name>RESOURCE_NAME</name> | ||
<resourceCapacity.maximumCapacity>500</resourceCapacity.maximumCapacity> | ||
<resourceCapacity.minimumCapacity>0</resourceCapacity.minimumCapacity> | ||
</RegisteredResource> | ||
</SKBlock_TimeSeries> | ||
~~~ | ||
|
||
- **businessType**: B45 means "The GSK is proportional to a merit order list" | ||
- **mktPSRType.psrType**: standard code defining the network element on which the shifting should operate: | ||
- **A04**: generators | ||
- **A05**: loads | ||
- **flowDirection.direction**: direction in which the generation change on this element can operate: | ||
- **A01**: "UP". Up signifies that the available power can be used by the Purchasing area to increase energy. | ||
- **A02**: "DOWN". Down signifies that the available power can be used by the Purchasing area to decrease energy. | ||
- **measurement_Unit.name**: unit of the GLSK. Only "MAW" (megawatt) is possible in this case. | ||
- **attributeInstanceComponent.position**: the relative position of the current timestamp in the applicability timeframe | ||
of the current **Period** tag (first timestamp has position 1) | ||
- **RegisteredResource**: describes the network element that should be shifted | ||
- **mRID**: unique ID of network element in the network. "codingScheme="A02"" means it is a CGMES ID. | ||
- **name**: human-readable name | ||
- **resourceCapacity.maximumCapacity**: maximum generation/load capacity to respect on the resource, in **measurement_Unit.name** | ||
- **resourceCapacity.minimumCapacity**: minimum generation/load capacity to respect on the resource, in **measurement_Unit.name** |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,198 @@ | ||
# CSE GLSK | ||
|
||
## Header | ||
|
||
~~~xml | ||
<GSKDocument DtdVersion="5" DtdRelease="0" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="gsk-document.xsd"> | ||
<DocumentIdentification v="NAME"/> | ||
<DocumentVersion v="1"/> | ||
<DocumentType v="B22"/> | ||
<ProcessType v="A01"/> | ||
<SenderIdentification v="SENDER_EIC" codingScheme="A01"/> | ||
<SenderRole v="A36"/> | ||
<ReceiverIdentification v="RECEIVER_EIC" codingScheme="A01"/> | ||
<ReceiverRole v="A04"/> | ||
<CreationDateTime v="2017-10-30T09:27:21Z"/> | ||
<GSKTimeInterval v="2016-07-28T22:00Z/2016-07-29T22:00Z"/> | ||
<Domain v="REGION_EIC" codingScheme="A01"/> | ||
... | ||
</GSKDocument> | ||
~~~ | ||
|
||
Contents of the header: | ||
- **DocumentIdentification**: ID for the document | ||
- **DocumentVersion**: version of the document | ||
- **DocumentType**: standard code defining the document type*. In the example above, "B22" means "Generation and load shift keys document". | ||
- **ProcessType**: standard code defining the process type*. In the example above, "A01" means "day ahead". | ||
- **SenderIdentification**: ID of the sender of the GLSK document*. Usually an [ENTSO-E EICode](https://www.entsoe.eu/data/energy-identification-codes-eic/). | ||
- **SenderRole**: standard code defining the role of the sender*. In the example above, "A36" means "capacity coordinator". | ||
- **ReceiverIdentification**: ID of the receiver of the GLSK document*. Usually an [ENTSO-E EICode](https://www.entsoe.eu/data/energy-identification-codes-eic/). | ||
- **ReceiverRole**: standard code defining the role of the receiver*. In the example above, "A04" means "system operator". | ||
- **CreationDateTime**: document creation time. | ||
- **GSKTimeInterval**: time interval of applicability of the GSK document. | ||
- **Domain**: ID of the geographical applicability of the document. Usually an [ENTSO-E EICode](https://www.entsoe.eu/data/energy-identification-codes-eic/). | ||
|
||
_*Refer to the [ENTSO-E website](https://www.entsoe.eu/publications/electronic-data-interchange-edi-library/) for the | ||
complete reference documents._ | ||
_You can find a complete list of codes [in the XSDs](https://www.entsoe.eu/Documents/EDI/Library/CIM_xsd_package.zip). | ||
Note that codes that begin with "Z" are region-specific._ | ||
|
||
## GLSK Definition | ||
|
||
Proper GLSK are defined within the tag **TimeSeries**. Generally, every TSO defines its own **TimeSeries**. | ||
|
||
~~~xml | ||
<...Block> | ||
<TimeSeriesIdentification v="1"/> | ||
<BusinessType v="Z02"/> | ||
<Area v="REGION_EIC" codingScheme="A01"/> | ||
<Name v="REGION_NAME"/> | ||
<TimeInterval v="2022-11-26T18:00Z/2022-11-26T19:00Z"/> | ||
<...Block></...Block> | ||
</TimeSeries> | ||
~~~ | ||
|
||
- **TimeSeriesIdentification**: unique ID of the **TimeSeries** in the document. | ||
- **BusinessType**: code defining the type of network element to be shifted: | ||
- **Z02**: generators | ||
- **Z05**: loads | ||
- **Area**: geographical applicability of the **TimeSeries**. Type is given by the content of **codingScheme**: | ||
- A01: the coding scheme is the [EICode](https://www.entsoe.eu/data/energy-identification-codes-eic/), maintained by ENTSO-E. | ||
- A02: the coding scheme used for Common Grid Model Exchange Standard (CGMES). | ||
- A10: the coding scheme for the preceding attribute is the Global Location Number (GLN 13) or Global Service Relation Number (GSRN 18), maintained by GS1. | ||
- ... other region-specific codes*. | ||
- **Name**: human-readable name of the region. | ||
- **TimeInterval**: time interval of applicability of the GLSK document. | ||
- **...Block**: one or multiple GLSK blocks containing actual values, can be of different types, explained in the following paragraphs. | ||
|
||
_*Refer to the [ENTSO-E website](https://www.entsoe.eu/publications/electronic-data-interchange-edi-library/) for the | ||
complete reference documents._ | ||
_You can find a complete list of codes [in the XSDs](https://www.entsoe.eu/Documents/EDI/Library/CIM_xsd_package.zip)._ | ||
|
||
### Manual GLSK | ||
|
||
The **ManualGSKBlock** tag can be used to define manually all the UCTE nodes associated with their weight within the GLSK. | ||
|
||
~~~xml | ||
<ManualGSKBlock> | ||
<Factor v="1"/> | ||
<Node> | ||
<Name v="Node1"/> | ||
<Factor v="0.19"/> | ||
</Node> | ||
<Node> | ||
<Name v="Node2"/> | ||
<Factor v="1.99"/> | ||
</Node> | ||
... | ||
</ManualGSKBlock> | ||
~~~ | ||
|
||
- **Factor**: a multiplier for all following factor values. | ||
- **Node**: list of custom GLSK definitions | ||
- **Name**: UCTE ID of the node on which the generation/load should be shifted | ||
- **Factor**: the shift key for the given node | ||
|
||
### Proportional Block | ||
|
||
The **PropGSKBlock** and **PropLSKBlock** tags can be used to define [proportional GLSK](/input-data/glsk/glsk.md#proportional-to-target-power-glsk). | ||
**PropGSKBlock** affects generators, and **PropLSKBlock** affects loads. | ||
|
||
~~~xml | ||
<PropGSKBlock> | ||
<Factor v="0.5"/> | ||
</PropGSKBlock> | ||
<PropLSKBlock> | ||
<Factor v="0.5"/> | ||
<Node> | ||
<Name v="Node1"/> | ||
</Node> | ||
<Node> | ||
<Name v="Node2"/> | ||
</Node> | ||
<Node> | ||
<Name v="Node3"/> | ||
</Node> | ||
</PropLSKBlock> | ||
~~~ | ||
|
||
- **Factor**: a multiplier for all following factor values. | ||
- **Node** (optional): list of custom GLSK definitions | ||
- **Name**: UCTE ID of the node on which the generation/load should be shifted | ||
|
||
_Note: if no **Node** is defined in the block, all generators/loads in the network (for the given region) are affected_ | ||
|
||
### Reserve Block | ||
|
||
The **ReserveGSKBlock** tag can be used to define [remaining capacity GLSK](/input-data/glsk/glsk.md#proportional-to-remaining-capacity). | ||
|
||
~~~xml | ||
<ReserveGSKBlock> | ||
<Factor v="1"/> | ||
<Node> | ||
<Name v="Node1"/> | ||
<Pmin v="0"/> | ||
<Pmax v="-29"/> | ||
</Node> | ||
<Node> | ||
<Name v="Node2"/> | ||
<Pmin v="0"/> | ||
<Pmax v="-29"/> | ||
</Node> | ||
</ReserveGSKBlock> | ||
~~~ | ||
|
||
- **Factor**: a multiplier for all following factor values. | ||
- **Node**: list of custom GLSK definitions | ||
- **Name**: UCTE ID of the node on which the generation/load should be shifted | ||
- **Pmin**: minimum active power target | ||
- **Pmax**: maximum active power target (can be < Pmin, if shifting needs to decrease generation / increase load, | ||
like in example above) | ||
|
||
### Merit-order Block | ||
|
||
The **MeritOrderGSKBlock** tag can be used to define [merit-order GLSK](/input-data/glsk/glsk.md#merit-order-glsk). | ||
|
||
~~~xml | ||
<MeritOrderGSKBlock> | ||
<Factor v="1"/> | ||
<Up> | ||
<Factor v="1"/> | ||
<Node> | ||
<Name v="NodeUp1"/> | ||
<Pmax v="-360"/> | ||
</Node> | ||
<Node> | ||
<Name v="NodeUp2"/> | ||
<Pmax v="-384"/> | ||
</Node> | ||
<Node> | ||
<Name v="NodeUp3"/> | ||
<Pmax v="-411"/> | ||
</Node> | ||
</Up> | ||
<Down> | ||
<Factor v="1"/> | ||
<Node> | ||
<Name v="NodeDown1"/> | ||
<Pmin v="-122"/> | ||
</Node> | ||
<Node> | ||
<Name v="NodeDown2"/> | ||
<Pmin v="-260"/> | ||
</Node> | ||
</Down> | ||
</MeritOrderGSKBlock> | ||
~~~ | ||
|
||
- **Factor**: a multiplier for all following factor values. | ||
- **Up**: list of nodes used to increase generation / decrease load | ||
- **Factor**: a multiplier for all **Up** factor values. | ||
- **Node**: list of custom GLSK definitions, **sorted by ascending merit order** | ||
- **Name**: UCTE ID of the node on which the generation/load should be shifted | ||
- **Pmax**: maximum active power target on the node | ||
- **Down**: list of nodes used to decrease generation / increase load | ||
- **Factor**: a multiplier for all **Down** factor values. | ||
- **Node**: list of custom GLSK definitions, **sorted by ascending merit order** | ||
- **Name**: UCTE ID of the node on which the generation/load should be shifted | ||
- **Pmax**: maximum active power target on the node |