Skip to content

Latest commit

 

History

History
136 lines (101 loc) · 10.8 KB

README.md

File metadata and controls

136 lines (101 loc) · 10.8 KB

Radiomics Extraction and Evaluation from Binary 3D (DICOM) Segmentation Masks

The segmentations used in this project represent a pair of the type tumor - ablation for liver cancer tumors. The ablation can be replaced with another type of segmentation, such as a predicted tumor segmentation (using a separate algorithm).

The evaluation metrics include:

Requirements

The following non-standard libraries are required to use the full functionality of the project for DICOM image reading and processing.

Main Functions and Operations Performed

  1. A_read_files_info.py (optional)
    • DicomReader.py
  2. B_ResampleSegmentations.py
  3. C_mainDistanceVolumeMetrics.py
    • VolumeMetrics.py
    • DistanceMetrics.py
    • scripts/ellipsoid_inner_outer.py
    • scripts/plot_ablation_margin_hist.py
  4. D_compile_population_radiomics.py (optional)
    • if batch processing (for multiple segmentations) have been enabled this script will compile all the features from the outpt CSV files into one single file.
  5. E_radiomics_stats.py (optional)
    • various plots and statistics for the features that have been previously extracted

Usage

The scripts are called (internally) in alphabetical order using the folllowing logic:

Read Images --> Resample --> Extract Distance Metrics  --> Extract Volume Metrics  --> Plot Distance Metrics --> Output Metrics to Xlsx file in Tabular format

image

PyRadiomics automatically checks if the source CT image and the derived mask have the same dimensions. If not, resampling is performed in the background. This function only operates with the path to the patient folder that can have all source CT image, segmentation masks, other files, all in one folder. It does that by creating a dictionary of paths based on the metadata information that was encoded in the ReferencedImageSequenceTag and SourceImageSequence. I have previously encoded the mapping information (which is also an anonymization pipeline) in the DICOM-Anonymization-Segmentation-Mapping

Input

ap = argparse.ArgumentParser()
ap.add_argument("-i", "--rootdir", required=False, help="path to the patient folder to be processed")
ap.add_argument("-o", "--plots_dir", required=True, help="path to the output images")
ap.add_argument("-b", "--input_batch_proc", required=False, help="input csv file for batch processing")
args = vars(ap.parse_args())

The main function where to run the program from is A_read_files_info.py. The function can either work with a single patient image folder by calling the function like:

python A_read_files_info.py --i "C:\Users\MyUser\MyPatientFolderwithDicomAndSegmentationImages --o "C:\OutputFilesandImages"

For Batch Processing option the input is an Excel (.xlsx) file with the following headers:

Patient_ID Ablation_IR_Date Nr_Lesions Patient_Dir_Paths
C001 20160103 2 ['D:\Users\User1\Pats\Pat_C001']
C002 20181108 1 ['D:\Users\User1\Pats\Pat_C002']

The algorithm starts by iterating through all the patient folders provided in the column "Patient_Dir_Paths". Of course it's not absolutely necessarry to use the data structured in the way I did. Moreover, the A_read_files_info.py can be skipped altogether, especially when you know the mapping between your Source (original) CT image -> Segmentation1 -> Segmentation2. In this specific case my Segmentation1 is called "tumor_segmentation" and Segmentation2 is called "ablation_segmentation", which are 2 separate structures/tissue within my organ of interest (that's the liver). If you already know the file mapping between your images (i.e. which image is related to which image, aka more explicit, from which CT source image comes each segmentation) you can move the next steps which are B_ResampleSegmentations.py and C_mainDistanceVolumeMetrics.py.

Resampling (Resizing)

In my case resampling was necessary because not only my 2 segmentation masks had different sizes [x, y, z] , but they also had different spacings in-between the slices. If your images differ only in size then you can use the SimpleITK Paste Image function. However, if the spacing differs, resampling is necesarry otherwise we cannot compare the 2 images using the Distance and Volume metrics.

The file that does the resampling and resizing job is B_ResampleSegmentations.py. First the images need to be read and loaded using the SimpleITK Python library. My segmentations and CT images were saved in multiple DICOM slices (images) in a DICOM folder. The script DicomReader.py reads all the DICOM slices of an image/segmentation and returns a single variable which is an object in SimpleITK format. The segmentation masks are resampled in the same dimensions and spacing (however still anisotropic) before calling the DistanceMetrics.py and VolumeMetrics.py.

This resampling script can be called like:
import SimpleITK as sitk
import DicomReader as Reader
tumor_segmentation_sitk, tumor_sitk_reader = Reader.read_dcm_series(tumor_path, True)
ablation_segmentation_sitk, ablation_sitk_reader = Reader.read_dcm_series(ablation_path, True)
resizer = ResizeSegmentation(ablation_segmentation_sitk, tumor_segmentation_sitk) # object instantiation
tumor_segmentation_resampled = resizer.resample_segmentation() # SimpleITK image object

The actual resampling operation is performed using the SimpleITK ResampleImageFilter and NearestNeighbour Interpolation such that no new segmentation mask labels are generated.

Segmentation Evaluation Metrics

The segmentation Evaluation Metrics are called from the script C_mainDistanceVolumeMetrics.py which calls:

  • DistanceMetrics.py
  • VolumeMetrics.py
  • RadiomicsMetrics - features extracted using the Python library PyRadiomics. You can find a list of all the featuers that can be computed using this PyRadiomics here. I used only the volumes, sphericity, intensity and axis values. The same as for Resampling, both these scripts take as input arguments SimpleITK image objects. They can be called for example like:

surface_distance_metrics = DistanceMetrics(ablation_segmentation, tumor_segmentation_resampled)
ablation_radiomics_metrics = RadiomicsMetrics(source_ct_ablation, ablation_segmentation)
evaloverlap = VolumeMetrics()
evaloverlap.set_image_object(ablation_segmentation, tumor_segmentation_resampled)

Inner and Outer Ellipsoidal Approximations

image

The inner (green) and outer (orange) ellipsoidal approximations of a segmented object (blue) are calculated using convex optimization according to "S. P. Boyd and L. Vandenberghe, Convex optimization. Cambridge, UK ; New York: Cambridge University Press, 2004." Their implementation in CVXPY was employed to compute the ellipsoids. The outer volume was computed using SVD and the inner volume was computed as the sqrt(det(B)) * Ball(0,1).

Output

The output is a Excel (.xlsx) file in tabular format that returns radiomics (feature values) per patient and per lesion. Aditionally a histogram that describes the Euclidean distances between the tumor and ablation (my 2 segmentations files) are generated. The script for plotting the histogram uses the Surface Euclidean Distances extracted using SimpleITK using the Maurer et. al algorithm is in scripts/plot_ablation_margin_hist.py. To compute the histogram the following steps are followed for the Maurer et. al algorithm:

  1. compute the contour surface of the object (face+edge+vertex connectivity : fullyConnected=True, face connectivity only : fullyConnected=False (default mode)
  2. convert from SimpleITK format to Numpy Array Img
  3. remove the zeros from the contour of the object, NOT from the distance map
  4. compute the number of 1's pixels in the contour
  5. instantiate the Signed Mauerer Distance map for the object (negative numbers also)
  6. Multiply the binary surface segmentations with the distance maps. The resulting distance maps contain non-zero values only on the surface (they can also contain zero on the surface)

histogram_example

Inner and Outer Ellipsoids Fitted around a segmentation (orange points).

inner outer ellipsoid 2

Patient Data Structure for my case

The patient data consists of files and folder has the following folder structure and organization:

`Patient_C001  
        |Series_1  
          |CAS-Recordings (* .xml files)   
          | 2016-09-13_07-15-32 ...
                                          |Segmentations
                                            |Segmentation_No3
                                                        |0001.dcm
                                                        |0002.dcm
                                                        |003.dcm
          |CT.1.2.392...dcm
          |CT.1.2.393...dcm
          |CT.1.2.3..dcm  
        |Series_2
        |Series_3`