You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
I am running Ubuntu Xenial 16.04 with Kinetic in a VirtualBox on a MacBook Pro, so I don't know if this is a general problem to Xenial/Kinetic or some artifact of the VirtualBox.
The laptop_battery_monitor works while the laptop is plugged in to the mains, but when the adapter is disconnected, the node dies. Resulting in:
[WARN] [WallTime: 1472477308.423277] Battery : unable to check laptop battery state [[Errno 19] No such device]
[laptop_battery-2] process has finished cleanly
I tracked it down to what I think is a kernel module problem. Running grep "" * in /sys/class/power_supply/BAT0/ when plugged in gives:
alarm:0
capacity:100
capacity_level:Full
cycle_count:0
grep: device: Is a directory
energy_full:50000000
energy_full_design:50000000
energy_now:50000000
manufacturer:innotek
model_name:1
grep: power: Is a directory
power_now:0
present:1
serial_number:0
status:Full
grep: subsystem: Is a directory
technology:Unknown
type:Battery
uevent:POWER_SUPPLY_NAME=BAT0
uevent:POWER_SUPPLY_STATUS=Full
uevent:POWER_SUPPLY_PRESENT=1
uevent:POWER_SUPPLY_TECHNOLOGY=Unknown
uevent:POWER_SUPPLY_CYCLE_COUNT=0
uevent:POWER_SUPPLY_VOLTAGE_MIN_DESIGN=10000000
uevent:POWER_SUPPLY_VOLTAGE_NOW=10000000
uevent:POWER_SUPPLY_POWER_NOW=0
uevent:POWER_SUPPLY_ENERGY_FULL_DESIGN=50000000
uevent:POWER_SUPPLY_ENERGY_FULL=50000000
uevent:POWER_SUPPLY_ENERGY_NOW=50000000
uevent:POWER_SUPPLY_CAPACITY=100
uevent:POWER_SUPPLY_CAPACITY_LEVEL=Full
uevent:POWER_SUPPLY_MODEL_NAME=1
uevent:POWER_SUPPLY_MANUFACTURER=innotek
uevent:POWER_SUPPLY_SERIAL_NUMBER=0
voltage_min_design:10000000
voltage_now:10000000
Whereas when the power is unplugged we get:
alarm:0
capacity:100
capacity_level:Normal
cycle_count:0
grep: device: Is a directory
energy_full:50000000
energy_full_design:50000000
energy_now:50000000
manufacturer:innotek
model_name:1
grep: power: Is a directory
grep: power_now: No such device
present:1
serial_number:0
status:Discharging
grep: subsystem: Is a directory
technology:Unknown
type:Battery
uevent:POWER_SUPPLY_NAME=BAT0
uevent:POWER_SUPPLY_STATUS=Discharging
uevent:POWER_SUPPLY_PRESENT=1
uevent:POWER_SUPPLY_TECHNOLOGY=Unknown
uevent:POWER_SUPPLY_CYCLE_COUNT=0
uevent:POWER_SUPPLY_VOLTAGE_MIN_DESIGN=10000000
uevent:POWER_SUPPLY_VOLTAGE_NOW=10000000
uevent:POWER_SUPPLY_ENERGY_FULL_DESIGN=50000000
uevent:POWER_SUPPLY_ENERGY_FULL=50000000
uevent:POWER_SUPPLY_ENERGY_NOW=50000000
uevent:POWER_SUPPLY_CAPACITY=100
uevent:POWER_SUPPLY_CAPACITY_LEVEL=Normal
uevent:POWER_SUPPLY_MODEL_NAME=1
uevent:POWER_SUPPLY_MANUFACTURER=innotek
uevent:POWER_SUPPLY_SERIAL_NUMBER=0
voltage_min_design:10000000
voltage_now:10000000
As you can see power_now is present but there is no device.
I am running Ubuntu Xenial 16.04 with Kinetic in a VirtualBox on a MacBook Pro, so I don't know if this is a general problem to Xenial/Kinetic or some artifact of the VirtualBox.
The laptop_battery_monitor works while the laptop is plugged in to the mains, but when the adapter is disconnected, the node dies. Resulting in:
I tracked it down to what I think is a kernel module problem. Running
grep "" *
in/sys/class/power_supply/BAT0/
when plugged in gives:Whereas when the power is unplugged we get:
As you can see
power_now
is present but there is no device.A fix may be to change line 181 and 182 to
But then the node would report 0 even though the current may be something else.
The text was updated successfully, but these errors were encountered: