code_opticalD.m
218 lines (161 loc) · 5.66 KB
/
code_opticalD.m
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
%%%%%CONSTANTS%%%%%%
%Uniform pressure field//////Units= atm
P= 1;
%Line strength for target frequency and temperature//// Units= cm-2/atm
S= 3.16e-02;
%Target center frequency///// Units= cm-1
mu_o= 4988.655;
%Uniform Temparature and molecular mass of gas
T=296;
M=44;
%broadening coefficients for air and gas////// Units= cm-1/atm
bc_air= 0.077;
bc_self= 0.104;
%%%%%%MESH%%%%%
%Mesh size
N=50;
n_ray=2*(N-1);
%% coordinates%%
x= linspace(0,1,N);
y= linspace(0,1,N);
%Plot the mesh grid
[xx,yy]=meshgrid(x,y);
figure, plot(xx,yy,'g');
hold on;
plot(yy,xx,'g');
set(gca,'Color',[0,0,0])
hold on;
%Defing array for concentration of species at cell center
conc = zeros(N-1,N-1);
dx= 1/N;
%coordinates of cell centers, lasers and detectors
x_cell = zeros(N-1,N-1);
y_cell = zeros(N-1,N-1);
%top hat profile defined centered at x=0.25, y=0.25 for radius= 0,125 units
for i= 1:1:N-1
for j=1:1:N-1
x_cell(i,j) = (x(j)+x(j+1))/2;% coordinates of cell center
y_cell(i,j) = (y(i)+y(i+1))/2;
% distance= sqrt((x_cell(i,j)-0.25)^2 + (y_cell(i,j)-0.35)^2);
% %condition for concentration distribution
% if distance<=0.125
% conc(i,j)= 0.18*(0.5 + 0.5*erf(0.4*(0.25-distance))); % top-hat function
% end
% distance= sqrt((x_cell(i,j)-0.55)^2 + (y_cell(i,j)-0.75)^2);
% %condition for concentration distribution
% if distance<=0.075
% conc(i,j)= 0.18*(0.5 + 0.5*erf(0.4*(0.25-distance))); % top-hat function
% end
distance=sqrt(x_cell(i,j)^2+y_cell(i,j)^2);
if distance<0.5
cosG=0.25*(1-cos(2*pi*(x_cell(i,j)+0.5)^0.8))*(1-cos(2*pi*(y_cell(i,j)+0.5)^(2/3)));
else
cosG=0;
end
cosGauss=1.09*(0.3*cosG + 0.8*(exp(-(9*(x_cell(i,j)-0.2)^2+(6*(y_cell(i,j)-0.1)^2)))+exp(-(8*(x_cell(i,j)-0.7)^2+(30*(y_cell(i,j)-0.7)^2)))));
conc(i,j)= 0.18*cosGauss;
end
end
fprintf('Concentration loaded\n');
%coordinates for lasers
prompt='No. of lasers:';
n_laser= input(prompt);
prompt1='Values of angles in degrees (Range:[-90,90]):';
angles=zeros(n_laser,1);
for i=1:1:n_laser
angles(i,1)=input(prompt1);
end
x_laser=zeros(n_ray,n_laser);
y_laser=zeros(n_ray,n_laser);
x_det=zeros(n_ray,n_laser);
y_det=zeros(n_ray,n_laser);
for i=1:1:n_laser
[var1,var2,var3,var4]=laser(angles(i),N);
x_laser(:,i)=var1(:);
y_laser(:,i)=var2(:);
x_det(:,i)=var3(:);
y_det(:,i)=var4(:);
end
fprintf('Coordinates of lasers loaded\n');
for i=1:1:n_laser
plot(x_laser(:,i),y_laser(:,i),'r.');
end
for i=1:1:n_laser
plot(x_det(:,i),y_det(:,i),'b.');
end
hold off;
%Surface plot of concentration distribution
figure,surface(x_cell,y_cell,conc);
%Line-shape function: VOIGT PROFILE%%%%
gamma_G= 3.581e-07*mu_o*sqrt(T/M); % HWHM for Doppler broadening line
C_L= zeros(N-1,N-1); % Weight of Lorentzian profile
C_G= zeros(N-1,N-1); % Weight of Gaussian profile
gamma_V= zeros(N-1,N-1); % HWHM Voigt Profile
for i= 1:1:N-1
for j=1:1:N-1
gamma_L= P*(bc_self*conc(i,j)+bc_air*(1-conc(i,j))); % HWHM pressure broadening
d= (gamma_L-gamma_G)/(gamma_L+gamma_G);
C_L(i,j)= 0.68188 + 0.61293*d - 0.18384*d*d - 0.11568*d*d*d;
C_G(i,j)= 0.32460 - 0.61825*d + 0.17681*d*d + 0.12109*d*d*d;
gamma_V(i,j)= 0.5346*gamma_L + sqrt(0.2166*gamma_L*gamma_L + gamma_G*gamma_G); % HWHM Voigt
end
end
fprintf('Begin: calculation of ray length\n');
%%%calculating length of each ray inside each box
laser_len = zeros((N-1)*(N-1),n_ray,n_laser);
for k=1:1:n_laser
for i=1:1:n_ray
for j=1:1:(N-1)*(N-1)
%coordinates of the cell
ji=ceil(j/(N-1));
jj=rem(j-1,N-1)+1;
%definig the rectangle
xbox = [x(jj) x(jj) x(jj+1) x(jj+1) x(jj)];
ybox = [y(ji) y(ji+1) y(ji+1) y(ji) y(ji)];
% Laser 1: ith ray
x_line_1 = [x_laser(i,k) x_det(i,k)];
y_line_1 = [y_laser(i,k) y_det(i,k)];
%Intersection with ray from Laser 1
[xi_1, yi_1] = polyxpoly(x_line_1, y_line_1, xbox, ybox);
%Length of ray inside the rectangle for LASER 1
if isempty(xi_1)
laser_len(j,i,k) = 0;
else
laser_len(j,i,k) = sqrt((xi_1(2)-xi_1(1))^2 + (yi_1(2)-yi_1(1))^2);
end
end
end
end
fprintf('End: Calculation of ray length\n');
%Line funciton
VP = zeros(N-1,N-1); % Voigt profile
%Laser intensities
I = zeros(100,n_ray,n_laser);
fprintf('Begin: Wavenumber loop\n');
%%%%%%wave number iteration main loop
mu=linspace(4986.168,4991.1458,100);
I_o= zeros(1,100);
mT = zeros(N-1,N-1);% Modulation index
%modulation amplitude
a=0.2;
wn= mu_o;
% Voigt profile function
for i= 1:1:N-1
for j=1:1:N-1
VP(i,j)= (C_L(i,j)/pi)*((gamma_V(i,j)/((wn-mu_o)^2 + (gamma_V(i,j))^2))) + (C_G(i,j)/gamma_V(i,j))*sqrt(log(2)/pi)*exp((-log(2)*(wn-mu_o)^2)/(gamma_V(i,j))^2);
end
end
%calculating optical depth%%%% Number of views= 3 %
% Optical Depth is calculated for each laser
OD = zeros(n_ray,n_laser);
%Optical depth measurement
for l=1:1:n_laser
for i=1:1:n_ray
for j=1:1:N-1
for k=1:1:N-1
OD(i,l)= OD(i,l)+(-1/pi)*(P*conc(j,k)*S*VP(j,k)*laser_len((j-1)*(N-1)+k,i,l)); %%%%%%LASER 1
end
end
end
end
new_inverse