Notifications
You must be signed in to change notification settings - Fork 4
/
kostal_inverter.py
executable file
·110 lines (93 loc) · 4.45 KB
/
kostal_inverter.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
#!/usr/bin/env python2
# -*- coding: utf-8 -*-
#vi: set autoindent noexpandtab tabstop=4 shiftwidth=4
from dbus.mainloop.glib import DBusGMainLoop
try:
import gobject
from gobject import idle_add
except:
from gi.repository import GObject as gobject
from gi.repository.GObject import idle_add
import dbus
import dbus.service
import inspect
import pprint
import os
import sys
# velib path
sys.path.insert(1, os.path.join(os.path.dirname(__file__), './velib_python'))
from vedbus import VeDbusService
#def main(argv):
# global dbusObjects
class KostalInverter :
dbusservice = []
def __init__(self, dev, connection, instance, serial, product, firmwarev, pversion, position) :
#VERSION = '0.1'
print(__file__ + " starting up")
# instance = 50 + 0
# Have a mainloop, so we can send/receive asynchronous calls to and from dbus
#DBusGMainLoop(set_as_default=True)
#Put ourselves on to the dbus
self.dbusservice = VeDbusService('com.victronenergy.pvinverter.' + dev)
# Most simple and short way to add an object with an initial value of 5.
# dbusservice.add_path('/Ac/Power', value=1000, description='Total power', writeable=False)
# dbusservice.add_path('/DeviceType', value=1000, description='Total power', writeable=False)
# Add objects required by ve-api
self.dbusservice.add_path('/Mgmt/ProcessName', __file__)
self.dbusservice.add_path('/Mgmt/ProcessVersion', pversion)
self.dbusservice.add_path('/Mgmt/Connection', connection) # todo
self.dbusservice.add_path('/DeviceInstance', instance)
self.dbusservice.add_path('/ProductId', 0xFFFF) # 0xB012 ?
self.dbusservice.add_path('/ProductName', product)
#self.dbusservice.add_path('/CustomName', "PLC Mec meter")
self.dbusservice.add_path('/FirmwareVersion', firmwarev)
self.dbusservice.add_path('/Serial', serial)
self.dbusservice.add_path('/Connected', 1, writeable=True)
self.dbusservice.add_path('/ErrorCode', '(0) No Error')
self.dbusservice.add_path('/Position', position)
_kwh = lambda p, v: (str(v) + 'kWh')
_a = lambda p, v: (str(v) + 'A')
_w = lambda p, v: (str(v) + 'W')
_v = lambda p, v: (str(v) + 'V')
_s = lambda p, v: (str(v) + 's')
_x = lambda p, v: (str(v))
self.dbusservice.add_path('/Ac/Energy/Forward', None, gettextcallback=_kwh)
self.dbusservice.add_path('/Ac/L1/Current', None, gettextcallback=_a)
#self.dbusservice.add_path('/Ac/L1/Energy/Forward', None, gettextcallback=_kwh)
self.dbusservice.add_path('/Ac/L1/Power', None, gettextcallback=_w)
self.dbusservice.add_path('/Ac/L1/Voltage', None, gettextcallback=_v)
self.dbusservice.add_path('/Ac/L2/Current', None, gettextcallback=_a)
#self.dbusservice.add_path('/Ac/L2/Energy/Forward', None, gettextcallback=_kwh)
self.dbusservice.add_path('/Ac/L2/Power', None, gettextcallback=_w)
self.dbusservice.add_path('/Ac/L2/Voltage', None, gettextcallback=_v)
self.dbusservice.add_path('/Ac/L3/Current', None, gettextcallback=_a)
#self.dbusservice.add_path('/Ac/L3/Energy/Forward', None, gettextcallback=_kwh)
self.dbusservice.add_path('/Ac/L3/Power', None, gettextcallback=_w)
self.dbusservice.add_path('/Ac/L3/Voltage', None, gettextcallback=_v)
self.dbusservice.add_path('/Ac/Power', None, gettextcallback=_w)
self.dbusservice.add_path('/Ac/Current', None, gettextcallback=_a)
self.dbusservice.add_path('/Ac/Voltage', None, gettextcallback=_v)
self.dbusservice.add_path('/stats/connection_ok', 0, gettextcallback=_x, writeable=True)
self.dbusservice.add_path('/stats/connection_error', 0, gettextcallback=_x, writeable=True)
self.dbusservice.add_path('/stats/parse_error', 0, gettextcallback=_x, writeable=True)
self.dbusservice.add_path('/stats/repeated_values', 0, gettextcallback=_x, writeable=True)
self.dbusservice.add_path('/stats/last_connection_errors', 0, gettextcallback=_x, writeable=True)
self.dbusservice.add_path('/stats/last_repeated_values', 0, gettextcallback=_x, writeable=True)
self.dbusservice.add_path('/stats/reconnect', 0, gettextcallback=_x)
self.dbusservice.add_path('/Mgmt/intervall', 1, gettextcallback=_s, writeable=True)
def invalidate() :
self.set('/Ac/L1/Power',[])
self.set('/Ac/L2/Power',[])
self.set('/Ac/L3/Power',[])
self.set('/Ac/Power',[])
def set(self, name, value, round_digits=0) :
#print(str(name) + ' ' + str(value))
if isinstance(value, float):
self.dbusservice[name] = round(value, round_digits)
else:
self.dbusservice[name] = value
def get(self, name) :
v= self.dbusservice[name]
return v
def inc(self, name) :
self.dbusservice[name] += 1