Fervo 400MWe updates #40

Merged
merged 6 commits into from
Nov 12, 2024
Merged

Conversation

softwareengineerprogrammer
Copy link
Owner

@softwareengineerprogrammer softwareengineerprogrammer commented Nov 12, 2024

Updated values per today's GEOPHIRES sync

  1. Water loss fraction 2% -> 5%
  2. Plant lifetime 15 years -> 20 years
  3. Exploration capital cost $0M -> $30M
  4. Well drilling/completion cost $4M -> $3.84M
  5. Stimulation cost $78M -> $234M
  6. ITC 0% -> 30%
  7. Surface plant cost adjustment factor 0.78 -> 0.71 to approximate $1900/kW peak production
  8. Lateral length 4700 -> 7500 feet (has no effect on output, accounted for in well capex)

@softwareengineerprogrammer softwareengineerprogrammer changed the title Fervo 400mwe updates Fervo 400MWe updates Nov 12, 2024
@softwareengineerprogrammer softwareengineerprogrammer merged commit 7c4bc8a into main Nov 12, 2024
36 checks passed
@softwareengineerprogrammer
Copy link
Owner Author

Main repo PR: NREL#308

@softwareengineerprogrammer softwareengineerprogrammer deleted the fervo-400mwe-updates branch December 2, 2024 19:33