VHDL Source: olo_base_cc_status

Description

This component implements a clock crossing for slowly changing status information that does not have exact sample rates. It can for example be used to transfer a buffer fill level from one clock domain to another with minimal effort and without knowing anything about the frequencies of the two clocks (e.g. without knowing which one runs faster).

The entity ensures that data from the source clock domain is correctly transferred to the destination clock domain. The value at the destination clock domain is always correct in terms of "the exact same value was present on the input clock domain in one clock-cycle". The exact timing of the sampling points at which the data is transferred is generated by the entity itself, so it is unknown to the user. As a result, the entity does not guarantee to show transient states of the data signal in the source clock domain to the destination clock domain in cases of fast changing signals.

For the entity to work correctly, the data-rate must be significantly lower (10 x lower) than the slower clock frequency. Of course the signal can change more quickly but the clock crossing will skip some values in this case.

This block follows the general clock-crossing principles. Read through them for more information.

Generics

Name Type Default Description
Width_g positive 1 Width of the data-signal to clock-cross

Interfaces

Name In/Out Length Default Description
In_Clk in 1 - Source clock
In_RstIn in 1 '0' Reset input (high-active, synchronous to In_Clk)
In_RstOut out 1 N/A Reset output (see clock-crossing principles, synchronous to In_Clk)
In_Data in Width_g - Input data (synchronous to In_Clk)
Out_Clk in 1 - Destination clock
Out_RstIn in 1 '0' Reset input (high-active, synchronous to Out_Clk)
Out_RstOut out 1 N/A Reset output (see clock-crossing principles, synchronous to Out_Clk)
Out_Data out Width_g N/A Output data (synchronous to Out_Clk)

Architecture

The architecture of of olo_base_cc_status is based on the idea of passing around a valid pulse between the two clock-domains continuously. Data is transferred from In_Clk to Out_Clk together with the pulse.

This architecture is built based on olo_base_cc_simple and olo_base_cc_pulse.

architecture

Regarding timing constraints, refer to clock-crossing principles.