olo_intf_clk_meas

Back to Entity List

Status Information

Endpoint Badge Endpoint Badge Endpoint Badge

VHDL Source: olo_intf_clk_meas

Description

This entity measures the frequency of a clock under the assumption that the frequency of the main-clock is exactly correct. Generally the system cock comes from PS, the block is useful to verify if other clock are set the correct frequency.

This block contains Open Logic clock crossings, refer to clock crossing principles regarding timing constraints.

Generics

Name Type Default Description
ClkFrequency_g real - Frequency of the Clk clock (main-clock with a known frequency) in Hz.
Must be >= 100 Hz.
MaxClkTestFrequency_g real 1.0e9 Maximum frequency of the ClkTest clock which can be measured in Hz.
Must be >= 100 Hz.

Interfaces

Name In/Out Length Default Description
Clk in 1 - Clock
Rst in 1 '0' Reset input (high-active, synchronous to Clk)
ClkTest in 1 - Clock input of the clock to be measured.
Freq_Hz out 32 - Measured clock frequency of ClkTest in Hz. Updated once per second and always holds the last measured value (also between Freq_Valid pulses).
Freq_Valid out 1 - AXI4-Stream handshaking signal for Freq_Valid. Pulses high every second when a new Freq_Hz value is available.

Architecture

Below figure shows the architecture of the entity.

architecture

One pulse every second is generated using a olo_base_strobe_gen on the main clock. The frequency of the main clock is known and hence the generation of a 1 Hz pulse is trivial.

This pulse is then clock-crossed to the measurement clock domain (using olo_base_cc_pulse). On the measurement clock domain the number of clock cycles between two pulses is counted and transferred back to the main clock domain using a olo_base_cc_simple.

The logic on the main clock domain does forward the result to the output and additionally detects if no new measurement arrives between to 1 Hz pulses - in this case the measured clock obviously is stopped and the Freq_Hz output is set to zero. In case of a stopped clock no new measurement value is sent by the Measurement Clock Logic because this logic is synchronous to ClkTest and hence does not show any activity if this clock is stopped.

Due to the clock crossings and the internal logic, a certain minimum clock frequency is required for correct measurements. Main clocks (Clk) below 100 Hz are not supported and measurement values below that threshold may be imprecise.