Skip to content

SDS011 NOVA PM SENSOR

Thomas E. Horner edited this page Mar 12, 2019 · 12 revisions

About this

The SDS011 using principle of laser scattering, can get the particle concentration between 0.3 to 10μm in the air. It with digital output and built-in fan is stable and reliable.

Characteristics:

  • Accurate and reliable: laser detection, stable, good consistency.
  • Quick response: response time is less than 10 seconds when the scene changes.
  • High resolution: resolution of 0.3μg/m3.

Scope of application:

Detector of PM2.5. Purifier.

Working principle:

Using laser scattering principle. Light scattering can be induced when particles go through the detecting area. The scattered light is transformed into electrical signals and these signals will be amplified and processed. The number and diameter of particles can be obtained by analysis because the signal waveform has certain relations with the particles diameter.

Power supply:

  • Power Voltage:4.7~5.3V
  • Power supply:>1W
  • Supply voltage ripple:<20mV

Specification

What Comments
Identifier SDS011
Interface UART
Provides PM2.5 particles per million <= 2.5 micrometers
in micro-grams / m3
PM10 particles per million <= 10 micrometers
in micro-grams / m3
Properties none
Datasheet

Code

s = sensor.attach("SDS011", uart.UART1)
while true do
   pm_2_5 = s:read("PM2.5")
   pm_10 = s:read("PM10")
   print("PM2.5: "..pm_2_5..", PM10: "..pm_10)
   tmr.delayms(500)
end

Back to sensor list

Clone this wiki locally