Skip to content

ESPHome component to monitor a Seplos Battery Management System (Seplos-BMS) via UART or RS485

License

Notifications You must be signed in to change notification settings

tlamoureux24/esphome-seplos-bms

 
 

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

71 Commits
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

esphome-seplos-bms

ESPHome component to monitor Seplos BMS via UART or RS485

Supported devices

  • 1101-SP05 (reported by @JacquesdeBruyn)
  • 1101-SP15 (reported by @NosIreland)
  • 1101-SP16 (reported by @atze09)
  • 1101-ZH26 (reported by @faizan-elite)
  • 1101-MZ02 (reported by @fajera81)
  • 1101-SP76 (reported by @bagges)
  • 1101-SP101, PUSUNG-135 (reported by @manznOnly)
  • 1101-10E-SP76-16S (reported by @tobox)
  • 1101-10E-JK06-16S (Apex 48200, Apex BMS 48V200A, reported by @Pho3niX90)
  • Boqiang BMS007-LD43-16S-HW (reported by @xdilian) requires custom settings
    protocol_version: 0x26
    override_pack: 1
    
  • Boqiang BMS001-HS01-15S (reported by @xdilian) requires custom settings
    protocol_version: 0x26
    override_pack: 1
    override_cell_count: 10
    
  • Seplos BMS V3.0 Type C, B-48200-C (BMS16S200A-SP05B, FW 1.3, @Goaheadz) using esp8266-seplos-v3-example.yaml

Untested devices

  • EMU10xx
  • 11XX Series

Schematics

                  RS485                      UART
┌────────────┐              ┌──────────┐                ┌─────────┐
│            │              │          │<----- RX ----->│         │
│   Seplos   │<-----B- ---->│  RS485   │<----- TX ----->│ ESP32/  │
│    BMS     │<---- A+ ---->│  to TTL  │<----- GND ---->│ ESP8266 │
│            │<--- GND ---->│  module  │<----- 3.3V --->│         │<-- VCC
│            │              │          │                │         │<-- GND
└────────────┘              └──────────┘                └─────────┘

Please make sure to power the RS485 module with 3.3V because it affects the TTL (transistor-transistor logic) voltage between RS485 module and ESP.

RJ45 jack

Pin Purpose RS485-to-TTL pin Color T-568B
1 B- B- Orange-White
2 A+ A+ Orange
3 GND GND Green-White
4 NC
5 NC
6 GND
7 A+
8 B-

Please be aware of the different RJ45 pinout colors (T-568A vs. T-568B).

Requirements

Installation

You can install this component with ESPHome external components feature like this:

external_components:
  - source: github://syssi/esphome-seplos-bms@main

or just use the esp32-example.yaml as proof of concept:

# Install esphome
pip3 install esphome

# Clone this external component
git clone https://github.com/syssi/esphome-seplos-bms.git
cd esphome-seplos-bms

# Create a secrets.yaml containing some setup specific secrets
cat > secrets.yaml <<EOF
wifi_ssid: MY_WIFI_SSID
wifi_password: MY_WIFI_PASSWORD

mqtt_host: MY_MQTT_HOST
mqtt_username: MY_MQTT_USERNAME
mqtt_password: MY_MQTT_PASSWORD
EOF

# Validate the configuration, create a binary, upload it, and start logs
# If you use a esp8266 run the esp8266-examle.yaml
esphome run esp32-example.yaml

Screen recording

Example response all sensors enabled

[I][seplos_bms:031]: Telemetry frame received
[D][sensor:124]: 'seplos-bms cell voltage 1': Sending state 3.28800 V with 3 decimals of accuracy
[D][sensor:124]: 'seplos-bms cell voltage 2': Sending state 3.30400 V with 3 decimals of accuracy
[D][sensor:124]: 'seplos-bms cell voltage 3': Sending state 3.31600 V with 3 decimals of accuracy
[D][sensor:124]: 'seplos-bms cell voltage 4': Sending state 3.28700 V with 3 decimals of accuracy
[D][sensor:124]: 'seplos-bms cell voltage 5': Sending state 3.31000 V with 3 decimals of accuracy
[D][sensor:124]: 'seplos-bms cell voltage 6': Sending state 3.30100 V with 3 decimals of accuracy
[D][sensor:124]: 'seplos-bms cell voltage 7': Sending state 3.29700 V with 3 decimals of accuracy
[D][sensor:124]: 'seplos-bms cell voltage 8': Sending state 3.29300 V with 3 decimals of accuracy
[D][sensor:124]: 'seplos-bms cell voltage 9': Sending state 3.30500 V with 3 decimals of accuracy
[D][sensor:124]: 'seplos-bms cell voltage 10': Sending state 3.31200 V with 3 decimals of accuracy
[D][sensor:124]: 'seplos-bms cell voltage 11': Sending state 3.30400 V with 3 decimals of accuracy
[D][sensor:124]: 'seplos-bms cell voltage 12': Sending state 3.31100 V with 3 decimals of accuracy
[D][sensor:124]: 'seplos-bms cell voltage 13': Sending state 3.30700 V with 3 decimals of accuracy
[D][sensor:124]: 'seplos-bms cell voltage 14': Sending state 3.29000 V with 3 decimals of accuracy
[D][sensor:124]: 'seplos-bms cell voltage 15': Sending state 3.29400 V with 3 decimals of accuracy
[D][sensor:124]: 'seplos-bms cell voltage 16': Sending state 3.28900 V with 3 decimals of accuracy
[D][sensor:124]: 'seplos-bms min cell voltage': Sending state 3.28700 V with 3 decimals of accuracy
[D][sensor:124]: 'seplos-bms max cell voltage': Sending state 3.31600 V with 3 decimals of accuracy
[D][sensor:124]: 'seplos-bms max voltage cell': Sending state 3.00000  with 0 decimals of accuracy
[D][sensor:124]: 'seplos-bms min voltage cell': Sending state 4.00000  with 0 decimals of accuracy
[D][sensor:124]: 'seplos-bms delta cell voltage': Sending state 0.02900 V with 3 decimals of accuracy
[D][sensor:124]: 'seplos-bms average cell voltage': Sending state 3.30050 V with 3 decimals of accuracy
[D][sensor:124]: 'seplos-bms temperature 1': Sending state 29.82000 °C with 0 decimals of accuracy
[D][sensor:124]: 'seplos-bms temperature 2': Sending state 29.76000 °C with 0 decimals of accuracy
[D][sensor:124]: 'seplos-bms temperature 3': Sending state 29.67000 °C with 0 decimals of accuracy
[D][sensor:124]: 'seplos-bms temperature 4': Sending state 29.82000 °C with 0 decimals of accuracy
[D][sensor:124]: 'seplos-bms environment temperature': Sending state 29.81000 °C with 0 decimals of accuracy
[D][sensor:124]: 'seplos-bms mosfet temperature': Sending state 29.78000 °C with 0 decimals of accuracy
[D][sensor:124]: 'seplos-bms current': Sending state -6.54000 A with 2 decimals of accuracy
[D][sensor:124]: 'seplos-bms total voltage': Sending state 52.80000 V with 2 decimals of accuracy
[D][sensor:124]: 'seplos-bms power': Sending state -345.31198 W with 2 decimals of accuracy
[D][sensor:124]: 'seplos-bms charging power': Sending state 0.00000 W with 2 decimals of accuracy
[D][sensor:124]: 'seplos-bms discharging power': Sending state 345.31198 W with 2 decimals of accuracy
[D][sensor:124]: 'seplos-bms residual capacity': Sending state 133.86000 Ah with 2 decimals of accuracy
[D][sensor:124]: 'seplos-bms battery capacity': Sending state 170.00000 Ah with 2 decimals of accuracy
[D][sensor:124]: 'seplos-bms state of charge': Sending state 78.70000 % with 1 decimals of accuracy
[D][sensor:124]: 'seplos-bms rated capacity': Sending state 180.00000 Ah with 2 decimals of accuracy
[D][sensor:124]: 'seplos-bms charging cycles': Sending state 70.00000  with 0 decimals of accuracy
[D][sensor:124]: 'seplos-bms state of health': Sending state 100.00000 % with 1 decimals of accuracy
[D][sensor:124]: 'seplos-bms port voltage': Sending state 52.79000 V with 2 decimals of accuracy

Known issues and limitations

None.

Protocol

See SEPLOS BMS Communication Protocol_V2.0.pdf and Seplos 48v 100A BMS RS485 Protocol.pdf.

$ echo -ne "~20004642E00200FD37\r" | hexdump -ve '1/1 "%.2X."'
      7E.32.30.30.30.34.36.34.32.45.30.30.32.30.30.46.44.33.37.0D.

# Get pack #0 telemetry data (CID2 `0x42`)
TX -> "~20004642E00200FD37\r"
RX <- "~2000460010960001100CD70CE90CF40CD60CEF0CE50CE10CDC0CE90CF00CE80CEF0CEA0CDA0CDE0CD8060BA60BA00B970BA60BA50BA2FD5C14A0344E0A426803134650004603E8149F0000000000000000DC6C\r"

# Get system parameters (CID2 `0x47`)
TX -> "~200046470000FDA9\r"
RX <- ?

# Get protocol version (CID2 `0x4F`)
TX -> "~2000464F0000FD9A\r"
RX <- ?

# Get manufacturer info (CID2 `0x51`)
TX -> "~200046510000FDAE\r"
RX <- "~20004600C040313130312D5350313520020743414E50726F746F636F6C3A536F666172202020F046\r"

# Get management info (pylontech only?)
TX -> "~200046920000FDA9\r"
RX <- ?

# Get module serial number (pylontech only?)
TX -> "~200046930000FDA8\r"
RX <- ?

Debugging

If this component doesn't work out of the box for your device please update your configuration to enable the debug output of the UART component and increase the log level to the see outgoing and incoming serial traffic:

logger:
  level: DEBUG

uart:
  id: uart_0
  baud_rate: 9600
  tx_pin: ${tx_pin}
  rx_pin: ${rx_pin}
  rx_buffer_size: 384
  debug:
    dummy_receiver: false
    direction: BOTH
    after:
      delimiter: "\r"
    sequence:
      - lambda: UARTDebug::log_string(direction, bytes);

References

About

ESPHome component to monitor a Seplos Battery Management System (Seplos-BMS) via UART or RS485

Resources

License

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published

Languages

  • C++ 51.8%
  • Python 47.7%
  • Shell 0.5%