27 changes: 21 additions & 6 deletions examples/README.md
Original file line number Diff line number Diff line change
Expand Up @@ -27,12 +27,27 @@ show different communication features for the
[BMI323 shuttle](https://www.bosch-sensortec.com/media/boschsensortec/downloads/shuttle_board_flyer/bst-bmi323-sf000.pdf)
board:

* [`bmi088/bmi323_i2c_read_write.py`](./bmi323/bmi323_i2c_read_write.py)
* [`bmi088/bmi323_i2c_polling_streaming.py`](./bmi323/bmi323_i2c_polling_streaming.py)
* [`bmi088/bmi323_i2c_interrupt_streaming.py`](./bmi323/bmi323_i2c_interrupt_streaming.py)
* [`bmi088/bmi323_spi_read_write.py`](./bmi323/bmi323_spi_read_write.py)
* [`bmi088/bmi323_spi_polling_streaming.py`](./bmi323/bmi323_spi_polling_streaming.py)
* [`bmi088/bmi323_spi_interrupt_streaming.py`](./bmi323/bmi323_spi_interrupt_streaming.py)
* [`bmi323/bmi323_i2c_read_write.py`](./bmi323/bmi323_i2c_read_write.py)
* [`bmi323/bmi323_i2c_polling_streaming.py`](./bmi323/bmi323_i2c_polling_streaming.py)
* [`bmi323/bmi323_i2c_interrupt_streaming.py`](./bmi323/bmi323_i2c_interrupt_streaming.py)
* [`bmi323/bmi323_spi_read_write.py`](./bmi323/bmi323_spi_read_write.py)
* [`bmi323/bmi323_spi_polling_streaming.py`](./bmi323/bmi323_spi_polling_streaming.py)
* [`bmi323/bmi323_spi_interrupt_streaming.py`](./bmi323/bmi323_spi_interrupt_streaming.py)

## [`bmp390`](https://www.bosch-sensortec.com/products/environmental-sensors/pressure-sensors/bmp390/)

The examples in the [`bmp390`](./bmp390) folder
show different communication features for the
[BMP390 shuttle](https://www.bosch-sensortec.com/media/boschsensortec/downloads/shuttle_board_flyer/application_board_3_1/bst-bmp390-sf000.pdf)
board:

* [`bmp390/bmp390_i2c_read_write.py`](./bmp390/bmp390_i2c_read_write.py)
* [`bmp390/bmp390_i2c_polling_streaming.py`](./bmp390/bmp390_i2c_polling_streaming.py)
* [`bmp390/bmp390_i2c_interrupt_streaming.py`](./bmp390/bmp390_i2c_interrupt_streaming.py)
* [`bmp390/bmp390_spi_read_write.py`](./bmp390/bmp390_spi_read_write.py)
* [`bmp390/bmp390_spi_polling_streaming.py`](./bmp390/bmp390_spi_polling_streaming.py)
* [`bmp390/bmp390_spi_interrupt_streaming.py`](./bmp390/bmp390_spi_interrupt_streaming.py)



## Need a specific example or do not know how to read data from your sensor?
Expand Down
2 changes: 1 addition & 1 deletion examples/bmi323/bmi323_i2c_read_write.py
Original file line number Diff line number Diff line change
Expand Up @@ -30,7 +30,7 @@ def setup_logging(level: int = logging.DEBUG) -> logging.Logger:

logger.info(f"chip_id=0x{shuttle.sensor.chip_id:04X}")
logger.info(f"err_reg=0x{shuttle.sensor.err_reg:04X}")
logger.info(f"err_reg=0x{shuttle.sensor.status:04X}")
logger.info(f"status=0x{shuttle.sensor.status:04X}")

a_x, a_y, a_z = shuttle.sensor.acc_data
logger.info(f"acceleration=({a_x=:04X}, {a_y=:04X}, {a_z=:04X})")
Expand Down
Empty file added examples/bmp390/__init__.py
Empty file.
56 changes: 56 additions & 0 deletions examples/bmp390/bmp390_i2c_interrupt_streaming.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,56 @@
import logging
import struct
import sys
import time
from pathlib import Path

from umrx_app_v3.shuttle_board.bmp390.bmp390_shuttle import BMP390Shuttle


def setup_logging(level: int = logging.DEBUG) -> logging.Logger:
logger = logging.getLogger()
logger.setLevel(level)
stdout_handler = logging.StreamHandler(sys.stdout)
log_format = "(%(asctime)s) [%(levelname)-8s] %(filename)s:%(lineno)d: %(message)s"
log_formatter = logging.Formatter(log_format)
stdout_handler.setFormatter(log_formatter)
file_handler = logging.FileHandler(f"{Path(__file__).parent / Path(__file__).stem}.log", mode="w")
file_handler.setFormatter(log_formatter)
logger.addHandler(stdout_handler)
logger.addHandler(file_handler)
return logger


if __name__ == "__main__":
logger = setup_logging()
# This example is for Application Board 3.1 hardware
shuttle = BMP390Shuttle.on_hardware_v3_rev1()
shuttle.initialize()
shuttle.check_connected_hw()

shuttle.configure_i2c()
logger.info(f"chip_id=0x{shuttle.sensor.chip_id:02X}")
assert shuttle.sensor.chip_id == 0x60
_ = shuttle.sensor.compensate_temperature(0x0000) # cache temperature NVM registers
_ = shuttle.sensor.compensate_pressure(0x00, 24.0) # cache pressure NVM registers
shuttle.configure_interrupt_streaming()
shuttle.start_streaming()
time.sleep(0.1)
for idx in range(1000):
for streaming in shuttle.board.receive_interrupt_streaming_multiple(includes_mcu_timestamp=False):
sensor_id, packet, time_stamp, payload = streaming
pressure_b0, pressure_b1, pressure_b2, temp_b0, temp_b1, temp_b2, time_b0, time_b1, time_b2 = struct.unpack(
"<BBBBBBxxBBB", payload
)
raw_pressure = (pressure_b2 << 16) | (pressure_b1 << 8) | pressure_b0
raw_temperature = (temp_b2 << 16) | (temp_b1 << 8) | temp_b0
sensor_time = (time_b2 << 16) | (time_b1 << 8) | time_b0
compensated_temperature = shuttle.sensor.compensate_temperature(raw_temperature)
compensated_pressure = shuttle.sensor.compensate_pressure(raw_pressure, compensated_temperature)
logger.info(
f"[{idx=:03d}], pressure(Pa)={compensated_pressure:7.3f}, "
f"temperature(C)={compensated_temperature:3.3f}, "
f"time_stamp(s)={sensor_time / 25908.533}"
)
time.sleep(0.05)
shuttle.board.stop_interrupt_streaming()
56 changes: 56 additions & 0 deletions examples/bmp390/bmp390_i2c_polling_streaming.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,56 @@
import logging
import struct
import sys
import time
from pathlib import Path

from umrx_app_v3.shuttle_board.bmp390.bmp390_shuttle import BMP390Shuttle


def setup_logging(level: int = logging.DEBUG) -> logging.Logger:
logger = logging.getLogger()
logger.setLevel(level)
stdout_handler = logging.StreamHandler(sys.stdout)
log_format = "(%(asctime)s) [%(levelname)-8s] %(filename)s:%(lineno)d: %(message)s"
log_formatter = logging.Formatter(log_format)
stdout_handler.setFormatter(log_formatter)
file_handler = logging.FileHandler(f"{Path(__file__).parent / Path(__file__).stem}.log", mode="w")
file_handler.setFormatter(log_formatter)
logger.addHandler(stdout_handler)
logger.addHandler(file_handler)
return logger


if __name__ == "__main__":
logger = setup_logging()
# This example is for Application Board 3.1 hardware
shuttle = BMP390Shuttle.on_hardware_v3_rev1()
shuttle.initialize()
shuttle.check_connected_hw()

shuttle.configure_i2c()
logger.info(f"chip_id=0x{shuttle.sensor.chip_id:04X}")
assert shuttle.sensor.chip_id == 0x60
_ = shuttle.sensor.compensate_temperature(0x0000) # caching NVM registers
_ = shuttle.sensor.compensate_pressure(0x00, 24.0) # caching NVM registers
shuttle.configure_polling_streaming()
shuttle.start_streaming()
time.sleep(0.1)
for idx in range(1000):
for streaming in shuttle.board.receive_polling_streaming_multiple():
sensor_id, payload = streaming
(pressure_b0, pressure_b1, pressure_b2, temp_b0, temp_b1, temp_b2, time_b0, time_b1, time_b2) = (
struct.unpack("<BBBBBBxxBBB", payload)
)
raw_pressure = (pressure_b2 << 16) | (pressure_b1 << 8) | pressure_b0
raw_temperature = (temp_b2 << 16) | (temp_b1 << 8) | temp_b0
sensor_time = (time_b2 << 16) | (time_b1 << 8) | time_b0
compensated_temperature = shuttle.sensor.compensate_temperature(raw_temperature)
compensated_pressure = shuttle.sensor.compensate_pressure(raw_pressure, compensated_temperature)
logger.info(
f"[{idx=:03d}], pressure(Pa)={compensated_pressure:7.3f}, "
f"temperature(C)={compensated_temperature:3.3f}, "
f"time_stamp(s)={sensor_time / 25908.533}"
)
time.sleep(0.05)
shuttle.board.stop_polling_streaming()
49 changes: 49 additions & 0 deletions examples/bmp390/bmp390_i2c_read_write.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,49 @@
import logging
import sys
import time
from pathlib import Path

from umrx_app_v3.shuttle_board.bmp390.bmp390_shuttle import BMP390Shuttle


def setup_logging(level: int = logging.DEBUG) -> logging.Logger:
logger = logging.getLogger()
logger.setLevel(level)
stdout_handler = logging.StreamHandler(sys.stdout)
log_format = "(%(asctime)s) [%(levelname)-8s] %(filename)s:%(lineno)d: %(message)s"
log_formatter = logging.Formatter(log_format)
stdout_handler.setFormatter(log_formatter)
file_handler = logging.FileHandler(f"{Path(__file__).parent / Path(__file__).stem}.log", mode="w")
file_handler.setFormatter(log_formatter)
logger.addHandler(stdout_handler)
logger.addHandler(file_handler)
return logger


if __name__ == "__main__":
logger = setup_logging()
shuttle = BMP390Shuttle.on_hardware_v3_rev1()
shuttle.initialize()
shuttle.check_connected_hw()

shuttle.configure_i2c()

logger.info(f"chip_id=0x{shuttle.sensor.chip_id:02X}")
logger.info(f"rev_id=0x{shuttle.sensor.rev_id:02X}")
logger.info(f"err_reg=0x{shuttle.sensor.err_reg:02X}")
logger.info(f"status=0x{shuttle.sensor.status:02X}")
logger.info(f"pwr_ctrl=0b{shuttle.sensor.pwr_ctrl:08b}")
logger.info(f"odr=0b{shuttle.sensor.odr:08b}")
logger.info(f"osr=0b{shuttle.sensor.osr:08b}")

shuttle.sensor.pwr_ctrl = (1 << 0) | (1 << 1) | (0b11 << 4)
time.sleep(0.1)
logger.info(f"pwr_ctrl=0b{shuttle.sensor.pwr_ctrl:08b}")

raw_temperature = shuttle.sensor.temperature
compensated_temperature = shuttle.sensor.compensate_temperature(raw_temperature)
logger.info(f"temperature(raw)=0x{raw_temperature:06X}, temperature(C)={compensated_temperature}")
raw_pressure = shuttle.sensor.pressure
compensated_pressure = shuttle.sensor.compensate_pressure(raw_pressure, compensated_temperature)
logger.info(f"pressure(raw)=0x{raw_pressure:06X}, pressure(Pa)={compensated_pressure}")
logger.info(f"sensor_time=0x{shuttle.sensor.sensor_time:06X}")
57 changes: 57 additions & 0 deletions examples/bmp390/bmp390_spi_interrupt_streaming.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,57 @@
import logging
import struct
import sys
import time
from pathlib import Path

from umrx_app_v3.shuttle_board.bmp390.bmp390_shuttle import BMP390Shuttle


def setup_logging(level: int = logging.DEBUG) -> logging.Logger:
logger = logging.getLogger()
logger.setLevel(level)
stdout_handler = logging.StreamHandler(sys.stdout)
log_format = "(%(asctime)s) [%(levelname)-8s] %(filename)s:%(lineno)d: %(message)s"
log_formatter = logging.Formatter(log_format)
stdout_handler.setFormatter(log_formatter)
file_handler = logging.FileHandler(f"{Path(__file__).parent / Path(__file__).stem}.log", mode="w")
file_handler.setFormatter(log_formatter)
logger.addHandler(stdout_handler)
logger.addHandler(file_handler)
return logger


if __name__ == "__main__":
logger = setup_logging()
shuttle = BMP390Shuttle.on_hardware_v3_rev1()
shuttle.initialize()
shuttle.check_connected_hw()

shuttle.configure_spi()
_ = shuttle.board.read_spi(shuttle.CS, 0, 1) # dummy read is required, do not delete

logger.info(f"chip_id=0x{shuttle.sensor.chip_id:02X}")
assert shuttle.sensor.chip_id == 0x60
_ = shuttle.sensor.compensate_temperature(0x0000) # cache temperature NVM registers
_ = shuttle.sensor.compensate_pressure(0x00, 24.0) # cache pressure NVM registers
shuttle.configure_interrupt_streaming()
shuttle.start_streaming()
time.sleep(0.1)
for idx in range(1000):
for streaming in shuttle.board.receive_interrupt_streaming_multiple(includes_mcu_timestamp=False):
sensor_id, packet, time_stamp, payload = streaming
pressure_b0, pressure_b1, pressure_b2, temp_b0, temp_b1, temp_b2, time_b0, time_b1, time_b2 = struct.unpack(
"<xBBBBBBxxBBB", payload
)
raw_pressure = (pressure_b2 << 16) | (pressure_b1 << 8) | pressure_b0
raw_temperature = (temp_b2 << 16) | (temp_b1 << 8) | temp_b0
sensor_time = (time_b2 << 16) | (time_b1 << 8) | time_b0
compensated_temperature = shuttle.sensor.compensate_temperature(raw_temperature)
compensated_pressure = shuttle.sensor.compensate_pressure(raw_pressure, compensated_temperature)
logger.info(
f"[{idx=:03d}], pressure(Pa)={compensated_pressure:7.3f}, "
f"temperature(C)={compensated_temperature:3.3f}, "
f"time_stamp(s)={sensor_time / 25908.533:.3f}"
)
time.sleep(0.05)
shuttle.board.stop_interrupt_streaming()
58 changes: 58 additions & 0 deletions examples/bmp390/bmp390_spi_polling_streaming.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,58 @@
import logging
import struct
import sys
import time
from pathlib import Path

from umrx_app_v3.shuttle_board.bmp390.bmp390_shuttle import BMP390Shuttle


def setup_logging(level: int = logging.DEBUG) -> logging.Logger:
logger = logging.getLogger()
logger.setLevel(level)
stdout_handler = logging.StreamHandler(sys.stdout)
log_format = "(%(asctime)s) [%(levelname)-8s] %(filename)s:%(lineno)d: %(message)s"
log_formatter = logging.Formatter(log_format)
stdout_handler.setFormatter(log_formatter)
file_handler = logging.FileHandler(f"{Path(__file__).parent / Path(__file__).stem}.log", mode="w")
file_handler.setFormatter(log_formatter)
logger.addHandler(stdout_handler)
logger.addHandler(file_handler)
return logger


if __name__ == "__main__":
logger = setup_logging()
# This example is for Application Board 3.1 hardware
shuttle = BMP390Shuttle.on_hardware_v3_rev1()
shuttle.initialize()
shuttle.check_connected_hw()

shuttle.configure_spi()
_ = shuttle.board.read_spi(shuttle.CS, 0, 1) # dummy read is required, do not delete

logger.info(f"chip_id=0x{shuttle.sensor.chip_id:02X}")
assert shuttle.sensor.chip_id == 0x60
_ = shuttle.sensor.compensate_temperature(0x0000) # caching NVM registers
_ = shuttle.sensor.compensate_pressure(0x00, 24.0) # caching NVM registers
shuttle.configure_polling_streaming()
shuttle.start_streaming()
time.sleep(0.1)
for idx in range(1000):
for streaming in shuttle.board.receive_polling_streaming_multiple():
sensor_id, payload = streaming
(pressure_b0, pressure_b1, pressure_b2, temp_b0, temp_b1, temp_b2, time_b0, time_b1, time_b2) = (
struct.unpack("<xBBBBBBxxBBB", payload)
)
raw_pressure = (pressure_b2 << 16) | (pressure_b1 << 8) | pressure_b0
raw_temperature = (temp_b2 << 16) | (temp_b1 << 8) | temp_b0
sensor_time = (time_b2 << 16) | (time_b1 << 8) | time_b0
compensated_temperature = shuttle.sensor.compensate_temperature(raw_temperature)
compensated_pressure = shuttle.sensor.compensate_pressure(raw_pressure, compensated_temperature)
logger.info(
f"[{idx=:03d}], pressure(Pa)={compensated_pressure:7.3f}, "
f"temperature(C)={compensated_temperature:3.3f}, "
f"time_stamp(s)={sensor_time / 25908.533:.3f}"
)
time.sleep(0.05)
shuttle.board.stop_polling_streaming()
50 changes: 50 additions & 0 deletions examples/bmp390/bmp390_spi_read_write.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,50 @@
import logging
import sys
import time
from pathlib import Path

from umrx_app_v3.shuttle_board.bmp390.bmp390_shuttle import BMP390Shuttle


def setup_logging(level: int = logging.DEBUG) -> logging.Logger:
logger = logging.getLogger()
logger.setLevel(level)
stdout_handler = logging.StreamHandler(sys.stdout)
log_format = "(%(asctime)s) [%(levelname)-8s] %(filename)s:%(lineno)d: %(message)s"
log_formatter = logging.Formatter(log_format)
stdout_handler.setFormatter(log_formatter)
file_handler = logging.FileHandler(f"{Path(__file__).parent / Path(__file__).stem}.log", mode="w")
file_handler.setFormatter(log_formatter)
logger.addHandler(stdout_handler)
logger.addHandler(file_handler)
return logger


if __name__ == "__main__":
logger = setup_logging()
shuttle = BMP390Shuttle.on_hardware_v3_rev1()
shuttle.initialize()
shuttle.check_connected_hw()

shuttle.configure_spi()
_ = shuttle.board.read_spi(shuttle.CS, 0, 1) # dummy read is required, do not delete

logger.info(f"chip_id=0x{shuttle.sensor.chip_id:02X}")
logger.info(f"rev_id=0x{shuttle.sensor.rev_id:02X}")
logger.info(f"err_reg=0x{shuttle.sensor.err_reg:02X}")
logger.info(f"status=0x{shuttle.sensor.status:02X}")
logger.info(f"pwr_ctrl=0b{shuttle.sensor.pwr_ctrl:08b}")
logger.info(f"odr=0b{shuttle.sensor.odr:08b}")
logger.info(f"osr=0b{shuttle.sensor.osr:08b}")

shuttle.sensor.pwr_ctrl = (1 << 0) | (1 << 1) | (0b11 << 4)
time.sleep(0.1)
logger.info(f"pwr_ctrl=0b{shuttle.sensor.pwr_ctrl:08b}")

raw_temperature = shuttle.sensor.temperature
compensated_temperature = shuttle.sensor.compensate_temperature(raw_temperature)
logger.info(f"temperature(raw)=0x{raw_temperature:06X}, temperature(C)={compensated_temperature}")
raw_pressure = shuttle.sensor.pressure
compensated_pressure = shuttle.sensor.compensate_pressure(raw_pressure, compensated_temperature)
logger.info(f"pressure(raw)=0x{raw_pressure:06X}, pressure(Pa)={compensated_pressure}")
logger.info(f"sensor_time=0x{shuttle.sensor.sensor_time:06X}")
Loading
Loading